Feasibility of Dual-Energy CT in the Arterial Phase: Imaging After Endovascular Aortic Repair

被引:45
|
作者
Numburi, Uma D. [1 ,2 ,3 ]
Schoenhagen, Paul [1 ,2 ]
Flamm, Scott D. [1 ]
Greenberg, Roy K. [3 ,4 ,5 ]
Primak, Andrew N. [6 ]
Saba, Osama I. [6 ]
Lieber, Michael L. [7 ]
Halliburton, Sandra S. [1 ,2 ,3 ]
机构
[1] Cleveland Clin, Image Inst, Cleveland, OH 44195 USA
[2] Cleveland State Univ, Chem & Biomed Engn Dept, Cleveland, OH 44115 USA
[3] Cleveland Clin, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
[4] Cleveland Clin, Inst Heart & Vasc, Dept Vasc Surg, Cleveland, OH 44195 USA
[5] Cleveland Clin, Inst Heart & Vasc, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
[6] Siemens Healthcare, Malvern, PA USA
[7] Cleveland Clin, Lerner Res Inst, Dept Quantitat Hlth Sci, Cleveland, OH 44195 USA
关键词
aneurysm; aorta; dual-energy CT; endovascular repair; unenhanced CT; virtual CT; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; ANEURYSM;
D O I
10.2214/AJR.09.3872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to investigate replacing unenhanced and arterial single-energy CT acquisitions after endovascular aneurysm repair with one dual-energy CT arterial acquisition. SUBJECTS AND METHODS. Thirty patients underwent arterial dual-energy CT (80 and 140 kVp) and venous single-energy CT (120 kVp) after endovascular aneurysm repair, and the radiation doses were compared with those of a standard triple-phase protocol. Both virtual unenhanced and arterial images were generated with dual-energy CT. Images were reviewed clinically for detection of endoleaks and evaluation of stent and calcium appearance. The aortic luminal attenuation on virtual unenhanced CT images was compared with that on previously acquired true unenhanced images. Virtual unenhanced, arterial, and venous images were compared for thrombus attenuation. Single-energy CT and dual-energy CT images were compared for noise. RESULTS. Replacement of two (unenhanced, arterial) of three single-energy CT acquisitions with one dual-energy CT acquisition resulted in 31% radiation dose savings. All images were clinically interpretable. Thoracic (32 +/- 2 vs 35 +/- 4 HU) and abdominal (30 +/- 3 vs 35 +/- 5 HU) aortic attenuation was similar on virtual unenhanced and true unenhanced images. Thrombus attenuation was similar on virtual unenhanced (32 +/- 6 HU), arterial phase (33 +/- 7 HU), and venous phase (34 +/- 6 HU) images. Decreased stent and calcium attenuation was observed at some locations on virtual unenhanced images. Noise in the thoracic (10 +/- 1 HU) and abdominal (12 +/- 2 HU) aorta was lower on virtual unenhanced images than on true unenhanced images (13 +/- 4 HU, 19 +/- 5 HU). Noise was comparable for dual-energy and single-energy CT (thorax, 16 +/- 2 vs 13 +/- 2 HU; abdomen, 21 +/- 3 vs 23 +/- 5 HU). CONCLUSION. Virtual unenhanced and arterial phase images derived from dual-energy CT can replace true unenhanced and arterial phase single-energy CT images in follow-up after endovascular aneurysm repair (except immediately after the procedure), providing comparable diagnostic information with substantial dose savings.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 50 条
  • [21] Imaging the Spine with Dual-Energy CT
    Murray N.
    Le M.
    Ebrahimzadeh O.
    Alharthy A.
    Mohammed M.F.
    Ouellette H.A.
    Khosa F.
    Current Radiology Reports, 5 (9)
  • [22] Dual-Energy CT in Oncologic Imaging
    Foti, Giovanni
    Ascenti, Giorgio
    Agostini, Andrea
    Longo, Chiara
    Lombardo, Fabio
    Inno, Alessandro
    Modena, Alessandra
    Gori, Stefania
    TOMOGRAPHY, 2024, 10 (03) : 299 - 319
  • [23] Dual-energy CT Immediately after Endovascular Stroke Intervention: Prognostic Implications
    D. Morhard
    L. Ertl
    W. Gerdsmeier-Petz
    B. Ertl-Wagner
    G. Schulte-Altedorneburg
    CardioVascular and Interventional Radiology, 2014, 37 : 1171 - 1178
  • [24] Dual-energy CT Immediately after Endovascular Stroke Intervention: Prognostic Implications
    Morhard, D.
    Ertl, L.
    Gerdsmeier-Petz, W.
    Ertl-Wagner, B.
    Schulte-Altedorneburg, G.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (05) : 1171 - 1178
  • [25] Image Quality of Virtual Noncontrast Images Derived from Dual-energy CT Angiography after Endovascular Aneurysm Repair
    Sommer, Wieland H.
    Graser, Anno
    Becker, Christoph R.
    Clevert, Dirk A.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    Johnson, Thorsten R. C.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (03) : 315 - 321
  • [26] Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations
    Chandarana, Hersh
    Godoy, Myrna C. B.
    Vlahos, Ioannis
    Graser, Anno
    Babb, James
    Leidecker, Christianne
    Macari, Michael
    RADIOLOGY, 2008, 249 (02) : 692 - 700
  • [27] Endoleak Detection After Endovascular Repair of Thoracic Aortic Aneurysm Using Dual-Source Dual-Energy CT: Suitable Scanning Protocols and Potential Radiation Dose Reduction
    Flors, Lucia
    Leiva-Salinas, Carlos
    Norton, Patrick T.
    Patrie, James T.
    Hagspiel, Klaus D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (02) : 451 - 460
  • [28] Quantitative comparison of dual-energy CT and differential phase contrast CT imaging methods
    Zhang, Xin
    Su, Ting
    Xia, Dongmei
    Liang, Dong
    Ge, Yongshuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [29] Dual-Energy CT in Head and Neck Imaging
    Roele E.D.
    Timmer V.C.M.L.
    Vaassen L.A.A.
    van Kroonenburgh A.M.J.L.
    Postma A.A.
    Current Radiology Reports, 5 (5)
  • [30] Dual-Energy CT: Applications in Oncologic Imaging
    Schoepf, U.
    MEDICAL PHYSICS, 2016, 43 (06) : 3746 - 3746