Performance of enlarged blood pump models with five different impellers

被引:0
|
作者
Chua, LP [1 ]
Yu, SCM [1 ]
Leo, HL [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
关键词
blood pump model; impeller blade design;
D O I
10.1615/CritRevBiomedEng.v28.i12.220
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
in earlier studies, a 5:1 enlarged pump model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump had been constructed and the flow characteristics investigated. Although the results obtained were satisfactory, the medium used was air. A 5:1 enlarged pump model using water as the medium thus was designed and constructed. Five different impeller blade profile designs were used in the present study. By varying (1) the blade profile design: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed, the flow characteristics of the pump were investigated. It was found that the impeller with the higher number of blades, used in the forward and straight blade profiles, have the best performance.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [31] Influence mechanism of different tip curvatures on the performance of tip-leaned centrifugal impellers
    Wang, Zhongyi
    Qu, Feng
    Zhong, Xinquan
    Wang, Yanhua
    Lian, Chengyu
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 45 (07): : 1314 - 1321
  • [32] STUDIES ON ESTIMATING THE PERFORMANCE OF IMPELLERS WITH CUT-DOWN OF THE BLADE EDGE OF THE CENTRIFUGAL PUMP BY THE SURFACE SINGULARITY METHOD
    FURUKAWA, A
    CHENG, CC
    TAKAMATSU, Y
    JSME INTERNATIONAL JOURNAL SERIES II-FLUIDS ENGINEERING HEAT TRANSFER POWER COMBUSTION THERMOPHYSICAL PROPERTIES, 1990, 33 (03): : 525 - 530
  • [33] Application of different surrogate models on the optimization of centrifugal pump
    Wang, Wenjie
    Pei, Ji
    Yuan, Shouqi
    Zhang, Jinfeng
    Yuan, Jianping
    Xu, Changzheng
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (02) : 567 - 574
  • [34] Application of different surrogate models on the optimization of centrifugal pump
    Wenjie Wang
    Ji Pei
    Shouqi Yuan
    Jinfeng Zhang
    Jianping Yuan
    Changzheng Xu
    Journal of Mechanical Science and Technology, 2016, 30 : 567 - 574
  • [35] Investigation of hydraulic performance in an axial-flow blood pump with different guide vane outlet angle
    Sang, Xiaohu
    Zhou, Xiaojun
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (08): : 1 - 11
  • [36] Air-water two-phase flow performance of centrifugal pump impellers with various blade angles
    Sato, S
    Furukawa, A
    Takamatsu, Y
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1996, 39 (02) : 223 - 229
  • [37] Evaluation and performance comparison of different models for global solar radiation forecasting: a case study on five cities
    Ali, Mohamed A.
    Elsayed, Ashraf
    Elkabani, Islam
    Youssef, M. Elsayed
    Hassan, Gasser E.
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2023,
  • [38] Turbulent models and axial flow pump performance prediction
    Chen Hongxun
    Li Haifeng
    Shi Fajia
    Ma Zheng
    INTERNATIONAL JOURNAL OF TURBO & JET-ENGINES, 2007, 24 (01) : 1 - 9
  • [39] Performance of a newly developed implantable centrifugal blood pump
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ASAIO JOURNAL, 2001, 47 (05) : 559 - 562
  • [40] PRELIMINARY HYDRAULIC PERFORMANCE CHARACTERIZATION OF AN AXIAL BLOOD PUMP
    Chan, W. K.
    Wong, Y. W.
    Lum, M. F.
    Chong, V.
    Koh, S. Y.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2004, 4 (03) : 227 - 236