Performance of a newly developed implantable centrifugal blood pump

被引:9
|
作者
Tsukiya, T [1 ]
Taenaka, Y [1 ]
Tatsumi, E [1 ]
Takano, H [1 ]
机构
[1] Kazuyuki Ito Nikkiso Co Ltd, Natl Cardiovasc Ctr Yoshiaki Konishi, Dept Artificial Organs, Osaka 5658565, Japan
关键词
D O I
10.1097/00002480-200109000-00032
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The performance of the newly developed implantable centrifugal blood pump was investigated in vitro. The pump was developed with the end goal of building a versatile system that includes a left ventricular assist system with an internal secondary battery or an implantable biventricular assist system with two implantable blood pumps. The hydrodynamic characteristics and efficiency of the blood pump were evaluated, and the mechanical damage to the blood caused by the blood pump was assessed through a hemolysis test using fresh goat blood. The pump could generate 120 mm Hg at a flow rate of 5 L/min and a motor speed of 2,500 rpm. The electric input power to the pump was approximately 5 watts under these working conditions. The hemolysis caused by the pump was a bit higher than that by the former model, but stayed within an acceptable range. Performance of the pump in vitro was considered sufficient for a left ventricular assist device, although further design improvement is necessary in terms of hemolysis and system efficiency to improve biocompatibility of the pump.
引用
收藏
页码:559 / 562
页数:4
相关论文
共 50 条
  • [1] THE VIENNA IMPLANTABLE CENTRIFUGAL BLOOD PUMP
    SCHIMA, H
    TRUBEL, W
    WIESELTHALER, G
    SCHMIDT, C
    MULLER, MR
    SIEGL, H
    LOSERT, U
    WOLNER, E
    [J]. ARTIFICIAL ORGANS, 1994, 18 (07) : 500 - 505
  • [2] Design, Manufacturing and Tests of an Implantable Centrifugal Blood Pump
    Bock, Eduardo
    Antunes, Pedro
    Uebelhart, Beatriz
    Leao, Tarcisio
    Fonseca, Jeison
    Cavalheiro, Andre
    Santos Filho, Diolino
    Cardoso, Jose Roberto
    Utiyama, Bruno
    Leme, Juliana
    Silva, Cibele
    Andrade, Aron
    Arruda, Celso
    [J]. TECHNOLOGICAL INNOVATION FOR SUSTAINABILITY, 2011, 349 : 410 - +
  • [3] Development of an implantable centrifugal blood pump for circulatory assist
    Wakisaka, Y
    Taenaka, Y
    Chikanari, K
    Okuzono, Y
    Endo, S
    Takano, H
    [J]. ASAIO JOURNAL, 1997, 43 (05) : M608 - M614
  • [4] Establishment of flow estimation for an implantable centrifugal blood pump
    Wakisaka, Y
    Okuzono, Y
    Taenaka, Y
    Chikanari, K
    Masuzawa, T
    Takano, H
    [J]. ASAIO JOURNAL, 1997, 43 (05) : M659 - M662
  • [5] Relationship of blood pressure and pump flow in an implantable centrifugal blood pump during hypertension
    Akimoto, T
    Yamazaki, K
    Litwak, P
    Litwak, KN
    Tagusari, O
    Mori, T
    Antaki, JF
    Kameneva, MV
    Watach, MJ
    Umezu, M
    Tomioka, J
    Kormos, RL
    Koyanagi, H
    Griffith, BP
    [J]. ASAIO JOURNAL, 2000, 46 (05) : 596 - 599
  • [6] Performance of a new implantable cardiac assist centrifugal pump
    Tevaearai, HT
    Mueller, XM
    Jegger, D
    Augsburger, M
    Burki, M
    von Segesser, LK
    [J]. ARTIFICIAL ORGANS, 2001, 25 (01) : 67 - 69
  • [7] An implantable centrifugal blood pump for long term circulatory support
    Yamazaki, K
    Litwak, P
    Kormos, RL
    Mori, T
    Tagusari, O
    Antaki, JF
    Kameneva, M
    Watach, M
    Gordon, L
    Umezu, M
    Tomioka, J
    Koyanagi, H
    Griffith, BP
    [J]. ASAIO JOURNAL, 1997, 43 (05) : M686 - M691
  • [8] Pivot wear of a centrifugal blood pump developed for circulatory assist
    Takashi Yamane
    Katsunobu Nonaka
    Hisashi Miyoshi
    Osamu Maruyama
    Masahiro Nishida
    Ryo Kosaka
    Yoshiyuki Sankai
    Tatsuo Tsutsui
    [J]. Journal of Artificial Organs, 2008, 11 : 232 - 237
  • [9] Pivot wear of a centrifugal blood pump developed for circulatory assist
    Yamane, Takashi
    Nonaka, Katsunobu
    Miyoshi, Hisashi
    Maruyama, Osamu
    Nishida, Masahiro
    Kosaka, Ryo
    Sankai, Yoshiyuki
    Tsutsui, Tatsuo
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2008, 11 (04) : 232 - 237
  • [10] Development of a totally implantable biventricular bypass centrifugal blood pump system
    Nosé, Y
    Nakata, K
    Yoshikawa, M
    Letsou, GV
    Fujisawa, A
    Wolner, E
    Schima, H
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (02): : 775 - 779