Stopped-flow system with ozonizer for the estimation of low biochemical oxygen demand in environmental samples

被引:12
|
作者
Chee, Gab-Joo
Nomura, Yoko
Ikebukuro, Kazunori
Karube, Isao
机构
[1] Japan Agcy Marine Earth Sci & Technol, Extremobiosphere Res Ctr, Yokosuka, Kanagawa 2370061, Japan
[2] Tokyo Technol Univ, Sch Bion, Hachioji, Tokyo 1928580, Japan
[3] Tokyo Univ Agr & Technol, Fac Engn, Dept Biotechnol & Life Sci, Koganei, Tokyo 1848588, Japan
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 22卷 / 12期
关键词
ozonation; BOD sensor; biosensor; biofilm; artificial wastewater; pseudomonas putida;
D O I
10.1016/j.bios.2007.01.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The stopped-flow system with an ozonizer was developed to estimate low biochemical oxygen demand (1301)) in rivers. Rivers contain many biopersistent organic compounds such as humic acid, lignin, and gum arabic. Free radicals generated by self-decomposition of ozone were used as powerful oxidants to split organic compounds. Ozonysis of the samples was carried out by 42.4 g N-1 M-3 ozone for 3 min at pH 7.0. Artificial wastewater (AWW) solutions were employed as standard solutions for the calibrations of the BOD sensor. At a BOD of 1 mg l(-1), the sensor response after ozonation was 1.6-fold higher than that before ozonation. The response time of the BOD sensor was only 5 min, being independent of the concentrations, and the lower detection limit was 0.5 mg 1(-1) BOD. The degradations of lignin and tannic acid by ozonation were 54.1 and 42.3%, respectively. In the biosensor responses by ozonation, lignin, gum arabic, and surfactant increased by double or more compared with previous responses. BOD in rivers was estimated using the stopped-flow system. Environmental samples pretreated with ozone gave high responses to the biosensor that were similar to those of the conventional BOD5 method. Accordingly, a good correlation between the sensor and the conventional BOD5 was obtained (r = 0.989). The system has to evolve the highly sensitive BOD determination. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:3092 / 3098
页数:7
相关论文
共 50 条
  • [1] A STOPPED-FLOW CALORIMETER FOR BIOCHEMICAL APPLICATIONS
    HOWARTH, JV
    MILLAR, NC
    GUTFREUND, H
    BIOCHEMICAL JOURNAL, 1987, 248 (03) : 677 - 682
  • [2] STOPPED-FLOW CALORIMETRY FOR BIOCHEMICAL REACTIONS
    BALKO, B
    BERGER, RL
    FRIAUF, W
    ANALYTICAL CHEMISTRY, 1969, 41 (11) : 1506 - &
  • [3] STOPPED-FLOW SENSOR FOR DISSOLVED-OXYGEN
    WANG, J
    SARIN, L
    ANALYTICA CHIMICA ACTA, 1982, 134 (JAN) : 239 - 245
  • [4] ESTIMATION OF OPIATES IN URINE BY STOPPED-FLOW FLUOROIMMUNOASSAY
    GAIKWAD, A
    GOMEZHENS, A
    PEREZBENDITO, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11): : 450 - 453
  • [5] Biosensor for the estimation of low biochemical oxygen demand
    Chee, GJ
    Nomura, Y
    Karube, I
    ANALYTICA CHIMICA ACTA, 1999, 379 (1-2) : 185 - 191
  • [6] STOPPED-FLOW DETERMINATION OF CARBARYL AND ITS HYDROLYSIS PRODUCT IN MIXTURES IN ENVIRONMENTAL-SAMPLES
    QUINTERO, MC
    SILVA, M
    PEREZBENDITO, D
    TALANTA, 1988, 35 (12) : 943 - 948
  • [7] STOPPED-FLOW DETERMINATION OF IODIDE IN PHARMACEUTICAL AND FOOD SAMPLES
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    ANALYST, 1989, 114 (01) : 89 - 92
  • [8] LOW-TEMPERATURE STOPPED-FLOW SPECTROMETRY
    HANAHAN, D
    AULD, DS
    ANALYTICAL BIOCHEMISTRY, 1980, 108 (01) : 86 - 95
  • [9] Chemical oxygen demand (COD) sensor using a stopped-flow thin layer electrochemical cell
    Lee, KH
    Ishikawa, T
    Sasaki, S
    Arikawa, Y
    Karube, I
    ELECTROANALYSIS, 1999, 11 (16) : 1172 - 1179
  • [10] Chemical oxygen demand (COD) sensor using a stopped-flow thin layer electrochemical cell
    Res. Ctr. for Adv. Sci. and Technol., University of Tokyo, 4-6-1 Komaba, Meguro, Tokyo 153-8904, Japan
    不详
    Electroanalysis, 1600, 16 (1172-1179):