Enhanced Control of Three-Phase Grid-Connected Renewables with Fault Ride-Through Capability under Voltage Sags

被引:1
|
作者
Rey-Boue, Alexis B. [1 ]
Guerrero-Rodriguez, N. F. [2 ]
Stoeckl, Johannes [3 ]
Strasser, Thomas I. [3 ]
机构
[1] Univ Politecn Cartagena, Dept Elect Comp Technol & Projects, C Dr Fleming S-N, Cartagena 30202, Spain
[2] Pontificia Univ Catolica Madre & Maestra PUCMM, Engn Sci, Ave Abraham Lincoln Esq Romulo Betancourt, Santo Domingo 2748, Dominican Rep
[3] AIT Austrian Inst Technol, Ctr Energy Elect Energy Syst, Giefinggasse 2, A-1210 Vienna, Austria
关键词
controller hardware-in-the-loop; constant active power control; dual second-order generalized integrator frequency-locked loop; low-voltage ride-through; voltage sag; renewable energy system; POWER-CONTROL; PHOTOVOLTAIC SYSTEMS; CURRENT LIMITATION; LVRT CAPABILITY; CONVERTERS; INVERTERS; STRATEGY; SYNCHRONIZATION; VERIFICATION; SIMULATION;
D O I
10.3390/electronics11091404
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The uninterruptible operation of grid-connected renewables under the occurrence of grid voltage sags is addressed in this work. This is achieved due to the incorporation of an enhanced control algorithm of a renewable source. The low-voltage ride-through algorithm was developed in accordance to the voltage profile introduced by IEC 61400-21 regarding grid voltage sags. To guarantee continuous operation of the renewable agent during voltage sags, not only instantaneous reactive power but also instantaneous active power under moderate voltage sags was injected to the utility grid fulfilling grid code requirements. A dual second-order generalized integrator frequency-locked loop synchronization algorithm was used to estimate the system's frequency, together with the positive and the negative sequences of the three-phase utility grid voltages when unbalanced sags occurred. The current control was made in a stationary reference frame by using proportional-resonant regulators, and a DC voltage source was used to emulate the primary energy from any type of renewable system. The validation of the proposed control algorithm was conducted for a three-phase grid-connected renewable system with an apparent power of 500 kVA. The results from several experimental tests demonstrated the proper behavior of the enhanced algorithm.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Application of Dynamic Voltage Restorer in Fault Ride-Through of Grid-Connected Photovoltaic Storage System
    ZENG Guohui
    ZHANG Jie
    HUANG Bo
    Wuhan University Journal of Natural Sciences, 2020, 25 (04) : 343 - 351
  • [32] Unbalanced Voltage Sag Ride-through Capability for Three-phase Grid-tied Inverter with Low Inductance
    Nagai, Satoshi
    Itoh, Jun-ichi
    2020 IEEE 21ST WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2020, : 35 - 42
  • [33] An Enhanced Control Strategy for Three-phase ZVR Grid-Connected Inverter Under Unbalanced and Distorted Grid Voltage Conditions
    Sun, Guofa
    Hu, Xiaozhen
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 7448 - 7453
  • [34] Voltage Sag Detection in Grid-connected Photovoltaic Power Plant for Low Voltage Ride-through Control
    Al-Shetwi, Ali Qasem
    Sujod, Muhamad Zahim
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2019, 12 (04) : 384 - 392
  • [35] Fault Ride-Through Capability Improvement of Grid Connected PV System Using Dynamic Voltage Restorer
    AbuHussein, Ahmed
    Sadi, Mohammad Ashraf Hossain
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (12-13) : 1296 - 1307
  • [36] A Low-Voltage Ride-Through Strategy for Three-Phase Distributed Generation Inverters During Voltage Sags
    Nie Xiong
    Xie Yunxiang
    Chen Bing
    Zhang Xiaoyu
    Hei Chenyang
    Zeng Zhiwu
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [37] Research on Low Voltage Ride Through Control of PV Grid-connected Inverter Under Unbalance Fault
    Zhao, Huabin
    Wu, Na
    Fan, Shuxian
    Gao, Yan
    Liu, Lin
    Zhao, Zhenning
    Liu, Xingchen
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 3991 - 3996
  • [38] Modified STATCOM control strategy for fault ride-through capability enhancement of grid-connected PV/wind hybrid power system during voltage sag
    Hamdan, I
    Ibrahim, Ahmed M. A.
    Noureldeen, Omar
    SN APPLIED SCIENCES, 2020, 2 (03):
  • [39] Modified STATCOM control strategy for fault ride-through capability enhancement of grid-connected PV/wind hybrid power system during voltage sag
    I. Hamdan
    Ahmed M. A. Ibrahim
    Omar Noureldeen
    SN Applied Sciences, 2020, 2
  • [40] Evaluation of Low Voltage Ride-Through Capability of Synchronous Generator Connected to a Grid
    Yang Shicong
    Shagar, G. Viknash
    Ukil, Abhisek
    Jayasinghe, S. D. Gamini
    Gupta, Amit K.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,