Fault Ride-Through Capability Improvement of Grid Connected PV System Using Dynamic Voltage Restorer

被引:6
|
作者
AbuHussein, Ahmed [1 ]
Sadi, Mohammad Ashraf Hossain [2 ]
机构
[1] Gannon Univ, Dept Elect & Comp Engn, Erie, PA 16541 USA
[2] Univ Cent Missouri, Sch Technol, Warrensburg, MO USA
关键词
dynamic voltage restorer (DVR); fault ride-through (FRT); photovoltaic (PV); series dynamic braking resistor (SDBR); symmetrical; asymmetrical faults;
D O I
10.1080/15325008.2020.1854374
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When a fault occurs at a grid-connected photovoltaic (PV) system, the grid voltage drops significantly, and this causes a spike in the DC link voltage. The high DC voltage, in turn, causes faults in the Power-Electronics inverters and choppers. In addition, PV plants form a significant portion of modern power systems and disconnecting them during faults (as conventional) is no longer an option. This work proposes the dynamic voltage restorer (DVR) to improve the fault ride-through (FRT) capability of PV systems under a three-phase-to-ground fault. In order to evaluate the effectiveness of the proposed DVR method, its performance is compared with that of the series dynamic braking resistor (SDBR). The comparison is made in terms of performance and control complexity. Simulation results show that the DVR can improve the FRT capability seamlessly. Also, despite its higher cost and controller complexity, the proposed DVR outperforms the SDBR in all aspects.
引用
收藏
页码:1296 / 1307
页数:12
相关论文
共 50 条
  • [1] Improvement of Fault Ride-Through Capability of Grid Connected Wind Turbine Based on a Switched Reluctance Generator Using a Dynamic Voltage Restorer
    Al Ghamdi, Saeed A.
    SUSTAINABILITY, 2023, 15 (14)
  • [2] Application of Dynamic Voltage Restorer in Fault Ride-Through of Grid-Connected Photovoltaic Storage System
    ZENG Guohui
    ZHANG Jie
    HUANG Bo
    Wuhan University Journal of Natural Sciences, 2020, 25 (04) : 343 - 351
  • [3] Low Voltage Ride-Through Capability Improvement of Wind Power Generation Using Dynamic Voltage Restorer
    Hasegawa, Naohiro
    Kumano, Teruiiisa
    RECENT ADVANCES IN ENERGY AND ENVIRONMENT, 2010, : 166 - +
  • [4] Power Quality Improvement and Low Voltage Ride Through Capability in Hybrid Wind-PV Farms Grid-Connected Using Dynamic Voltage Restorer
    Benali, Abdelkrim
    Khiat, Mounir
    Allaoui, Tayeb
    Denai, Mouloud
    IEEE ACCESS, 2018, 6 : 68634 - 68648
  • [5] Low Voltage Ride through and fault ride through Capability of 40kw PV Model grid connected
    Mashaly, Sabah
    Abdallah, Mokhtar Hussien
    2016 SAUDI ARABIA SMART GRID (SASG), 2016,
  • [6] Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid Faults
    Wessels, Christian
    Gebhardt, Fabian
    Fuchs, Friedrich Wilhelm
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (03) : 807 - 815
  • [7] Low Voltage Ride Through Capability Enhancement of Grid Connected PV System by SDBR
    Hossain, Md Kamal
    Ali, Mohd Hasan
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [8] Enhancement of fault ride-through capability of grid-connected wind farm
    Bhadane K.V.
    Ballal M.S.
    Moharil R.M.
    Kulkarni H.R.
    Prasad H.
    International Journal of Power Electronics, 2021, 13 (03) : 267 - 280
  • [9] Increase of fault ride-through capability for the grid-connected wind farms
    Ko, H. S.
    Jatskevich, J.
    Dumont, G. A.
    Moshref, A.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 718 - +
  • [10] Enhancement of fault ride-through capability for grid-connected wind farm
    Sun, Shixian
    Tian, Jie
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (08): : 137 - 141