Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast

被引:123
|
作者
Albrecht, Moritz H. [1 ]
Scholtz, Jan-Erik [1 ]
Huesers, Kristina [1 ]
Beeres, Martin [1 ]
Bucher, Andreas M. [1 ]
Kaup, Moritz [1 ]
Martin, Simon S. [1 ]
Fischer, Sebastian [1 ]
Bodelle, Boris [1 ]
Bauer, Ralf W. [1 ]
Lehnert, Thomas [1 ]
Vogl, Thomas J. [1 ]
Wichmann, Julian L. [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
Monoenergetic plus; Monochromatic imaging; Computed tomography angiography; Image quality; Dual-energy CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; REDUCED IODINE LOAD; CHEST CT; QUALITY; NOISE;
D O I
10.1007/s00330-015-3970-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare quantitative image quality parameters in abdominal dual-energy computed tomography angiography (DE-CTA) using an advanced image-based (Mono+) reconstruction algorithm for virtual monoenergetic imaging and standard DE-CTA. Fifty-five patients (36 men; mean age, 64.2 +/- 12.7 years) who underwent abdominal DE-CTA were retrospectively included. Mono + images were reconstructed at 40, 50, 60, 70, 80, 90 and 100 keV levels and as standard linearly blended M_0.6 images (60 % 100 kV, 40 % 140 kV). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the common hepatic (CHA), splenic (SA), superior mesenteric (SMA) and left renal arteries (LRA) were objectively measured. Mono+ DE-CTA series showed a statistically superior CNR for 40, 50, 60, 70 and 80 keV (P < 0.031) compared to M_0.6 images for all investigated arteries except SMA at 80 keV (P = 0.08). CNR at 40 keV revealed a mean relative increase of 287.7 % compared to linearly blended images among all assessed arteries (P < 0.001). SNR of Mono+ images was consistently significantly higher at 40, 50, 60 and 70 keV compared to M_0.6 for CHA and SA (P < 0.009). Compared to linearly blended images, Mono+ reconstructions at low keV levels of abdominal DE-CTA datasets significantly improve quantitative image quality. aEuro cent Mono+ combines increased attenuation with reduced image noise compared to standard DE-CTA. aEuro cent Mono+ shows superior contrast-to-noise ratios at low keV compared to linearly-blended images. aEuro cent Contrast-to-noise ratio in monoenergetic DE-CTA peaks at 40 keV. aEuro cent Mono+ reconstructions significantly improve quantitative image quality at low keV levels.
引用
收藏
页码:1863 / 1870
页数:8
相关论文
共 50 条
  • [31] Deep learning image reconstruction to improve accuracy of iodine quantification and image quality in dual-energy CT of the abdomen: a phantom and clinical study
    Fukutomi, Akiyo
    Sofue, Keitaro
    Ueshima, Eisuke
    Negi, Noriyuki
    Ueno, Yoshiko
    Tsujita, Yushi
    Yabe, Shinji
    Yamaguchi, Takeru
    Shimada, Ryuji
    Kusaka, Akiko
    Hori, Masatoshi
    Murakami, Takamichi
    EUROPEAN RADIOLOGY, 2023, 33 (02) : 1388 - 1399
  • [32] Deep learning image reconstruction to improve accuracy of iodine quantification and image quality in dual-energy CT of the abdomen: a phantom and clinical study
    Akiyo Fukutomi
    Keitaro Sofue
    Eisuke Ueshima
    Noriyuki Negi
    Yoshiko Ueno
    Yushi Tsujita
    Shinji Yabe
    Takeru Yamaguchi
    Ryuji Shimada
    Akiko Kusaka
    Masatoshi Hori
    Takamichi Murakami
    European Radiology, 2023, 33 : 1388 - 1399
  • [33] Optimal virtual monoenergetic image in "TwinBeam" dual-energy CT for organs-at-risk delineation based on contrast-noise-ratio in head-and-neck radiotherapy
    Wang, Tonghe
    Ghavidel, Beth Bradshaw
    Beitler, Jonathan J.
    Tang, Xiangyang
    Lei, Yang
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (02): : 121 - 128
  • [34] Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT
    Jack Junchi Xu
    Lars Lönn
    Esben Budtz-Jørgensen
    Kristoffer L. Hansen
    Peter S. Ulriksen
    European Radiology, 2022, 32 : 7098 - 7107
  • [35] Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT
    Xu, Jack Junchi
    Lonn, Lars
    Budtz-Jorgensen, Esben
    Hansen, Kristoffer L.
    Ulriksen, Peter S.
    EUROPEAN RADIOLOGY, 2022, 32 (10) : 7098 - 7107
  • [36] Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus
    Bucolo, Giuseppe Mauro
    D'Angelo, Tommaso
    Yel, Ibrahim
    Koch, Vitali
    Gruenewald, Leon D.
    Othman, Ahmed E.
    Alizadeh, Leona Soraja
    Overhoff, Daniel P.
    Waldeck, Stephan
    Martin, Simon S.
    Mazziotti, Silvio
    Ascenti, Giorgio
    Blandino, Alfredo
    Vogl, Thomas J.
    Booz, Christian
    DIAGNOSTICS, 2023, 13 (10)
  • [37] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn’s disease
    Sang Min Lee
    Se Hyung Kim
    Su Joa Ahn
    Hyo-Jin Kang
    Ji Hee Kang
    Joon Koo Han
    European Radiology, 2018, 28 : 2525 - 2534
  • [38] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn's disease
    Lee, Sang Min
    Kim, Se Hyung
    Ahn, Su Joa
    Kang, Hyo-Jin
    Kang, Ji Hee
    Han, Joon Koo
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2525 - 2534
  • [39] Image quality improvement in head and neck angiography based on dual-energy CT and deep learning
    He Zhang
    Lulu Zhang
    Juan Long
    He Zhang
    Xiaonan Sun
    Shuai Zhang
    Aiyun Sun
    Shenman Qiu
    Yankai Meng
    Tao Ding
    Chunfeng Hu
    Kai Xu
    BMC Medical Imaging, 25 (1)
  • [40] Virtual monoenergetic imaging in rapid kVp-switching dual-energy CT (DECT) of the abdomen: impact on CT texture analysis
    Vinit Baliyan
    Hamed Kordbacheh
    Bimal Parameswaran
    Balaji Ganeshan
    Dushyant Sahani
    Avinash Kambadakone
    Abdominal Radiology, 2018, 43 : 2693 - 2701