Newborn screening for hepatorenal tyrosinemia by tandem mass spectrometry: analysis of succinylacetone extracted from dried blood spots

被引:66
|
作者
Allard, P
Grenier, A
Korson, MS
Zytkovicz, TH
机构
[1] Tufts New England Med Ctr, Div Genet, Boston, MA 02111 USA
[2] Tufts Univ, Sch Med, Boston, MA 02111 USA
[3] Univ Laval, Ctr Med, Dept Med Genet, St Foy, PQ G1V 4G2, Canada
[4] Univ Massachusetts, Sch Med, New England Newborn Screening Program, Jamaica Plain, MA 02130 USA
关键词
tyrosinemia; succinylacetone; newborn screening; dried blood spots; filter paper; tandem mass spectrometry;
D O I
10.1016/j.clinbiochem.2004.07.006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To develop a method for the determination of succinylacetone (SA) in dried blood spots (DBS) using tandem mass spectrometry (MS/MS). Methods: SA was extracted from DBS with an acetonitrile and water solution (80:20 by volume) containing formic acid and hydrazine hydrate (both at 0.1% by Volume), and analyzed by MS/MS with a total run time per sample under 2 min. The reference range for SA in newborns was determined by analyzing a control group of 3199 DBS. SA was also measured in stored newborn specimens from three patients diagnosed clinically with hepatorenal tyrosinernia (FIT). Results: The within-run precision was less than or equal to7.4% and total precision was less than or equal to 12.2% on blood spots fortified with SA at 2, 10, and 50 [mumol/L. The limit of quantitation was 1 mumol/L and the calibration was linear from 1 to 50 mumol/L. A comparison of SA analysis of this MS/MS method with an established enzyme assay indirectly quantitating SA by inhibition of delta-aminolevulinic acid clehydratase demonstrated a strong con-elation. The reference range in the control group of unaffected newborn was determined to be <2 mumol/L, while SA in retrieved DBS Frorri FIT patients was significantly elevated, measuring 46.7, 36.5. and 23.2 mumol/L. Conclusions: We report a simple method that can be Used for screening HT in newborns. Based on our limited experience, a 2 mumol/L Cutoff could result in up to 100% sensitivity and specificity. (C) 2004 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:1010 / 1015
页数:6
相关论文
共 50 条
  • [31] Tandem mass spectrometric analysis of dried blood spots for screening of mucopolysaccharidosis I in newborns
    Wang, D
    Eadala, L
    Sadilek, M
    Chamoles, NA
    Turecek, F
    Scott, CR
    Gelb, MH
    CLINICAL CHEMISTRY, 2005, 51 (05) : 898 - 900
  • [32] Newborn screening for hepatorenal tyrosinemia-I by tandem mass spectrometry using pooled samples: A four-year summary by the New England newborn screening program
    Zytkovicz, Thomas H.
    Sahai, Inderneel
    Rush, Amii
    Odewale, Adedoyin
    Johnson, Donna
    Fitzgerald, Eileen
    Britton, Deborah
    Eaton, Roger B.
    CLINICAL BIOCHEMISTRY, 2013, 46 (7-8) : 681 - 684
  • [33] Secondary use of dried blood spots from newborn screening
    Leung, Christy W. M.
    Cheng, N. S.
    Leung, T. F.
    HONG KONG MEDICAL JOURNAL, 2024, 30 (04) : 338 - 338
  • [34] Analysis of polyfluoroalkyl substances and bisphenol A in dried blood spots by liquid chromatography tandem mass spectrometry
    Wanli Ma
    Kurunthachalam Kannan
    Qian Wu
    Erin M. Bell
    Charlotte M. Druschel
    Michele Caggana
    Kenneth M. Aldous
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4127 - 4138
  • [35] Analysis of polyfluoroalkyl substances and bisphenol A in dried blood spots by liquid chromatography tandem mass spectrometry
    Ma, Wanli
    Kannan, Kurunthachalam
    Wu, Qian
    Bell, Erin M.
    Druschel, Charlotte M.
    Caggana, Michele
    Aldous, Kenneth M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (12) : 4127 - 4138
  • [36] Analysis of polyfluoroalkyl substances and bisphenol A in dried blood spots by liquid chromatography tandem mass spectrometry
    Ma, Wanli
    Kannan, Kurunthachalam
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [37] Validation of accuracy-based amino acid reference materials in dried-blood spots by tandem mass spectrometry for newborn screening assays
    Chace, DH
    Adam, BW
    Smith, SJ
    Alexander, JR
    Hillman, SL
    Hannon, WH
    CLINICAL CHEMISTRY, 1999, 45 (08) : 1269 - 1277
  • [38] Towards newborn screening for ornithine transcarbamylase deficiency: Fast non-chromatographic orotic acid quantification from dried blood spots by tandem mass spectrometry
    Janzen, Nils
    Terhardt, Michael
    Sander, Stefanie
    Demirkol, Mubeccel
    Gokcay, Gulden
    Peter, Michael
    Luecke, Thomas
    Sander, Johannes
    Das, Anibh M.
    CLINICA CHIMICA ACTA, 2014, 430 : 28 - 32
  • [39] Detection of everolimus from dried blood spots using liquid chromatography tandem mass spectrometry
    Boyd, Jessica
    Sadrzadeh, S. M. Hossein
    CLINICAL BIOCHEMISTRY, 2015, 48 (15) : 1016 - 1016
  • [40] Quantification of DNA in Neonatal Dried Blood Spots by Adenine Tandem Mass Spectrometry
    Durie, Danielle
    Yeh, Ed
    McIntosh, Nathan
    Fisher, Lawrence
    Bulman, Dennis E.
    Birnboim, H. Chaim
    Chakraborty, Pranesh
    Al-Dirbashi, Osama Y.
    ANALYTICAL CHEMISTRY, 2018, 90 (01) : 801 - 806