Influence of developer exhaustion on accuracy of quantitative digital subtraction radiography - An in vitro study

被引:6
|
作者
Fidler, A
Likar, B
Pernus, F
Skaleric, U
机构
[1] Univ Ljubljana, Fac Med, Dept Oral Med & Periodontol, SI-1000 Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Med, Dept Stomatol, SI-1000 Ljubljana, Slovenia
[3] Univ Ljubljana, Fac Med, Dept Elect Engn, SI-1000 Ljubljana, Slovenia
关键词
D O I
10.1067/moe.2000.107362
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim of the study was to evaluate the influence of developer exhaustion on accuracy of quantitative digital subtraction radiography. Study design. Six objects, each incorporating a section of dry human mandible, were radiographed with 4 exposure times. Baseline films were processed in fresh solutions, whereas follow-up films were processed in fresh and in increasingly exhausted solutions (ie, 1, 2, and 3 weeks old). Bone loss and bone gain were computer simulated in 17 regions of interest on baseline radiographs. Area and volume of changes in mineralization were measured in subtracted images, obtained by subtraction of baseline from their corresponding follow-up radiographs. Friedman's 2-way analysis of variance by ranks and Wilcoxon signed-rank test were used for statistical analysis. Results. Because of exhausted developer, bone loss was relatively underestimated from 6.6% to 16.5% (P < .05), whereas bone gain was relatively overestimated from 9.7% to 16.7% (P < .05). Conclusions. This in vitro study demonstrates that films for quantitative digital subtraction radiography should be processed in fresh developer or error might be introduced.
引用
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [31] Quantitative analysis of errors in alveolar crest level caused by discrepant projection geometry in digital subtraction radiography: An in vivo study
    Huh, KH
    Lee, SS
    Jeon, IS
    Yi, WJ
    Heo, MS
    Choi, SC
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 100 (06): : 750 - 755
  • [32] Accuracy of direct digital radiography for detecting occlusal caries in primary teeth compared with conventional radiography and visual inspection: an in vitro study
    Dias da Silva, P. R.
    Marques, M. Martins
    Steagall, W., Jr.
    Mendes, F. Medeiros
    Lascala, C. A.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (06) : 362 - 367
  • [33] Quantitative analysis of periodontal defects in a skull model by subtraction radiography using a digital imaging device
    Young, SJ
    Chaibi, MS
    Graves, DT
    Majzoub, Z
    Boustany, F
    Cochran, D
    Nummikoski, P
    JOURNAL OF PERIODONTOLOGY, 1996, 67 (08) : 763 - 769
  • [34] Validation of quantitative digital subtraction radiography using the electronically guided alignment device/impression technique
    Hausmann, E
    Allen, K
    Loza, J
    Buchanan, W
    Cavanaugh, PF
    JOURNAL OF PERIODONTOLOGY, 1996, 67 (09) : 895 - 899
  • [35] Assessment of simulated internal resorption cavities using digital and digital subtraction radiography: a comparative study
    Stephanopoulos, Georgios
    Mikrogeorgis, Georgios
    Lyroudia, Kleoniki
    DENTAL TRAUMATOLOGY, 2011, 27 (05) : 344 - 349
  • [36] Periapical healing after simplified endodontic treatments: A digital subtraction radiography study
    Angerame, Daniele
    De Biasi, Matteo
    Sossi, Davide
    Marigo, Luca
    Castagnola, Raffaella
    Somma, Francesco
    Castaldo, Attilio
    GIORNALE ITALIANO DI ENDODONZIA, 2013, 27 (02): : 74 - 79
  • [37] Accuracy of stimulated lesion detection using semiautomatic alignment for digital subtraction radiography in human subjects.
    Byrd, V
    Pulliam, R
    Reddy, MS
    Jeffcoat, MK
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2854 - 2854
  • [38] Influence of homeopathic treatment with comfrey on bone density around titanium implants. A digital subtraction radiography study in rats
    Sakakura, Celso Eduardo
    Neto, Rubens Spin
    Bellucci, Marina
    Wenzel, Ann
    Scaf, Gulnara
    Marcantonio, Elcio, Jr.
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (06) : 624 - 628
  • [39] Accuracy of direct digital radiography in the study of the root canal type
    Wu, D. M.
    Wu, Y. N.
    Guo, W.
    Sameer, S.
    DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (04) : 263 - 265
  • [40] Influence of Different Factors on the Accuracy of Digital Impressions of Multiple Implants: An In Vitro Study
    Zhang, Yi-Jie
    Qiao, Shi-Chong
    Qian, Shu-Jiao
    Zhang, Chu-Nan
    Shi, Jun-Yu
    Lai, Hong-Chang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 442 - 449