Impact of electric vehicles and realistic dish-Stirling solar thermal system on combined voltage and frequency regulation of multiarea hydrothermal system

被引:9
|
作者
Dekaraja, Biswanath [1 ]
Saikia, Lalit Chandra [1 ]
机构
[1] Natl Inst Technol Silchar, Dept Elect Engn, Silchar, Assam, India
关键词
CFOPDN-TID controller; combined voltage and frequency control; electric vehicles; RDSTS; ORDER PID CONTROLLER; POWER-PLANT; DESIGN; LFC; OPTIMIZATION; AGC;
D O I
10.1002/est2.370
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The effective and reliable operation of an interconnected power system (PS) is a major concern, because of the large amount of power contribution from the intermittent renewable energy sources to the power grid. Energy storage (ES) devices are employed to enhance the reliability of the PS operation. Electric vehicles (EVs) are a novel type of distributed ES device that may be utilized to compensate for power imbalances. This paper discusses the participation of EVs for combined frequency and voltage control under conventional PS along with a thermal, hydro, realistic dish-Stirling solar thermal system (RDSTS). Appropriate physical constraints such as governor dead band and generation rate constraints are equipped with thermal and hydro plants, and communication delay between the generating unit and load dispatch center is considered. An aggregate EVs model, RDSTS, and a new cascade controller named fractional-order proportional-derivative with filter coefficient cascaded with tilt-integral-derivative (CFOPDN-TID) controller are provided in all areas for various studies. An artificial flora algorithm is employed to determine the optimal value of the various controller parameters under several scenarios. The system dynamics of the CFOPDN-TID controller outperform the proportional-integral-derivative (PID) and TID controllers under various conditions. The incorporation of EVs improves the system performance in terms of less settling time, and peak deviation, and reduce oscillations. The system performance degrades with increases in the communication time delay of the EVs. The integration of RDSTS into the system provides better dynamics than the dish-Stirling solar thermal system. Numerous studies have been conducted to validate the robustness of the proposed CFOPDN-TID controller.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Thermal Modeling of a Pressurized Air Cavity Receiver for Solar Dish Stirling System
    Zou, Chongzhe
    Zhang, Yanping
    Falcoz, Quentin
    Neveu, Pierre
    Li, Jianlan
    Zhang, Cheng
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS (SOLARPACES 2016), 2017, 1850
  • [32] Performance Analysis of Lunar Dish Stirling Solar Thermal Power Generation System
    Li, Xueling
    Li, Bingqi
    Liu, Yang
    Song, Zhiwei
    Li, Yichao
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (12): : 3603 - 3610
  • [33] Voltage stability assessment of isolated hybrid dish-stirling solar thermal-diesel microgrid with STATCOM using mine blast algorithm
    Ranjan, Sudhanshu
    Das, Dulal Chandra
    Sinha, Nidul
    Latif, Abdul
    Hussain, S. M. Suhail
    Ustun, Taha Selim
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 196
  • [34] Electric Vehicle to grid support on combined frequency and voltage control of multiarea power system considering renewable energy
    Dekaraja, Biswanath
    Saikia, Lalit Chandra
    Ramoji, Satish Kumar
    Behera, Manoja Kumar
    Bhagat, Sanjeev Kumar
    Meseret, Getaneh Mesfin
    2022 IEEE INTERNATIONAL POWER AND RENEWABLE ENERGY CONFERENCE, IPRECON, 2022,
  • [35] Experimental analysis and numerical validation of the solar Dish/Stirling system connected to the electric grid
    Mendoza Castellanos, Luis Sebastian
    Galindo Noguera, Ana Lisbeth
    Carrillo Caballero, Gaylord Enrique
    Leandro De Souza, Andre
    Melian Cobas, Vladimir Rafael
    Silva Lora, Electo Eduardo
    Jose Venturini, Osvaldo
    RENEWABLE ENERGY, 2019, 135 : 259 - 265
  • [36] Impact of energy storage and flexible alternating current transmission devices in combined voltage and frequency regulation of multiarea multisource interconnected power system
    Dekaraja, Biswanath
    Saikia, Lalit Chandra
    ENERGY STORAGE, 2022, 4 (03)
  • [37] Frequency Control of a Realistic Dish Stirling Solar Thermal System and Accurate HVDC Models Using a Cascaded FOPI-IDDN-Based Crow Search Algorithm
    Babu, Naladi Ram
    Bhagat, Sanjeev Kumar
    Chiranjeevi, Tirumalasetty
    Pushkarna, Mukesh
    Saha, Arindita
    Kotb, Hossam
    AboRas, Kareem M.
    Alsaif, Faisal
    Alsulamy, Sager
    Ghadi, Yazeed Yasin
    Hermann, Djeudjo Temene
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2023, 2023
  • [38] Deregulated AGC of multi-area system incorporating dish-Stirling solar thermal and geothermal power plants using fractional order cascade controller
    Tasnin, Washima
    Saikia, Lalit Chandra
    Raju, More
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 101 : 60 - 74
  • [39] Frequency and voltage stabilisation in combined load frequency control and automatic voltage regulation of multiarea system with hybrid generation utilities by AC/DC links
    Naga Sai Kalyan, CH.
    Sambasiva Rao, G.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2020, 39 (10) : 1009 - 1029
  • [40] Particle Swarm Optimization-Based Power and Temperature Control Scheme for Grid-Connected DFIG-Based Dish-Stirling Solar-Thermal System
    Li, Yang
    Xiong, Binyu
    Su, Yixin
    Tang, Jinrui
    Leng, Zhiwen
    ENERGIES, 2019, 12 (07)