Enantioselective determination of azelnidipine in human plasma using liquid chromatography-tandem mass spectrometry

被引:15
|
作者
Kawabata, Kiyoshi
Samata, Naozumi
Urasaki, Yoko
Fukazawa, Ichiro
Uchida, Naoki
Uchida, Eiji
Yasuhara, Hajime
机构
[1] Sankyo Co Ltd, Drug Metab & Pharmacokinet Res Labs, Shinagawa Ku, Tokyo 1408710, Japan
[2] Showa Univ, Sch Med, Dept Pharmacol 2, Tokyo 104, Japan
关键词
azelnidipine; enantiomer separation; quantitative analysis; LC/APCI-MS/MS;
D O I
10.1016/j.jchromb.2007.01.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and simple method was developed for determination of the enantiomers of azeinidipine, (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, in human plasma using chiral liquid chromatography with positive ion atmospheric pressure chemical ionization tandem mass spectrometry. Plasma samples spiked with stable isotope-labeled azelnidipine, [H-2(6)]-azelnidipine, as an internal standard, were processed for analysis using a solid-phase extraction in a 96-well plate format. The azelnidipine enantiomers were separated on a chiral column containing alpha(1)-acid glycoprotein as a chiral selector under isocratic mobile phase conditions. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, monitoring the transitions from m/z 583 -> 167 for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, and from m/z 589 -> 167 for [H-2(6)]-azelnidipine. The standard curve was linear over the studied range (0.05-20 ng/mL), with r(2) > 0.997 using weighted (1/x(2)) quadratic regression, and the chromatographic run time was 5.0 min/injection. The intra- and inter-assay precision (coefficient of variation), calculated from the assay data of the quality control samples, was 1.2-8.2% and 2.4-5.8% for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, respectively. The accuracy was 101.2-117.0% for (R)-(-)-azelnidipine and 100.0-107.0% for (S)-(+)-azelnidipine. The overall recoveries for (R)-(-)-azelnidipine and (S)-(+)azelnidipine were 71.4-79.7% and 71.7-84.2%, respectively. The lower limit of quantification for both enantiomers was 0.05 ng/mL using 1.0 mL of plasma. All the analytes showed acceptable short-term, long-term, auto-sampler and stock solution stability. Furthermore, the method described above was used to separately measure the concentrations of the azelnidipine enantionters in plasma samples collected from healthy subjects who had received a single oral dose of 16 mg of azelnidipine. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:389 / 397
页数:9
相关论文
共 50 条
  • [31] Determination of faropenem in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Gao, Shouhong
    Chen, Wansheng
    Tao, Xia
    Miao, Haijun
    Yang, Shaolin
    Wu, Rong
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) : 5 - 12
  • [32] Determination of thalidomide concentration in human plasma by liquid chromatography-tandem mass spectrometry
    Bai, Nan
    Cui, Xiang-Yong
    Wang, Jin
    Sun, Chun-Guang
    Mei, He-Kun
    Liang, Bei-Bei
    Cai, Yun
    Song, Xiu-Jie
    Gu, Jing-Kai
    Wang, Rui
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (02) : 626 - 630
  • [33] Quantitative determination of sufentanil in human plasma by liquid chromatography-tandem mass spectrometry
    Palleschi, L
    Lucentini, L
    Ferretti, E
    Anastasi, F
    Amoroso, M
    Draisci, G
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (02) : 329 - +
  • [34] Quantitative determination of buagafuran in human plasma by liquid chromatography-tandem mass spectrometry
    Yang, Fen
    Wang, Hongyun
    Peng, Ao
    Liu, Ming
    Hu, Pei
    Jiang, Ji
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (20): : 1789 - 1794
  • [35] Sensitive determination of phloroglucinol in human plasma by liquid chromatography-tandem mass spectrometry
    Hohyun Kim
    Sang Beom Han
    Chromatographia, 2003, 57 : 539 - 542
  • [36] Enantioselective determination of ornidazole in human plasma by liquid chromatography-tandem mass spectrometry on a Chiral-AGP column
    Du, Jiangbo
    Ma, Zhiyu
    Zhang, Yifan
    Wang, Ting
    Chen, Xiaoyan
    Zhong, Dafang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 86 : 182 - 188
  • [37] Determination of metformin in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Liu, Ang
    Coleman, Stuart P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3695 - 3700
  • [38] Quantitative determination of nebivolol from human plasma using liquid chromatography-tandem mass spectrometry
    Nandania, Jatin
    Rajput, S. J.
    Contractor, Pritesh
    Vasava, Pragnesh
    Solanki, Bhavik
    Vohra, Mohsin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 923 : 110 - 119
  • [39] Determination of tiapride in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Ya Moon
    Bok Paek
    Hui-Hyun Kim
    Hye Young Ji
    Hye Won Lee
    Hyoung-Geun Park
    Hye Suk Lee
    Archives of Pharmacal Research, 2004, 27 : 901 - 905
  • [40] Determination of tiapride in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Moon, Y
    Paek, IB
    Kim, HH
    Ji, HY
    Lee, HW
    Park, HG
    Lee, HS
    ARCHIVES OF PHARMACAL RESEARCH, 2004, 27 (09) : 901 - 905