Durability of Wet Bond of Hybrid Laminates to Cast-in-Place Concrete

被引:28
|
作者
Li, Li [1 ]
Shao, Yixin [1 ]
Wu, Zhishen [2 ]
机构
[1] McGill Univ, Dept Civil Engn, Montreal, PQ H3A 2K6, Canada
[2] Ibaraki Univ, Dept Civil Engn, Hitachi, Ibaraki 3168511, Japan
关键词
Bonding; Carbon-glass hybrid laminates; Cast in place; Composite structures; Concrete; Dry bond; Durability; FRP formwork; FRP-concrete composite structure; Laminates; Load bearing capacity; Load capacity; Pull-off tests; Wet bond;
D O I
10.1061/(ASCE)CC.1943-5614.0000060
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wet bond is a chemical bond developed to connect fiber-reinforced polymer (FRP) stay-in-place formwork to cast-in-place concrete for a composite action. Curing of chemical adhesive and fresh concrete occurs simultaneously in wet bond. Since FRP-concrete composite structure so designed is strongly dependent on the bond between FRP and concrete, a durable bond is of paramount importance. This paper presents a study on durability performance of wet bond exposed to sustained low temperature, freeze-thaw cycles, and wet-dry cycles. Single lap pull-off tests were conducted to evaluate the effect of exposure on bond. It was found that both first crack load and ultimate load of wet bond were reduced in comparison to dry bond. This reduction was more severe in first crack load than in ultimate capacity and was associated with voids, thickness, and surface of adhesive layer. The epoxy in wet bond had reached comparable degree of cure to dry bond and even gained a higher T-g. Environmental exposures did not show more impact on wet bond than on dry bond.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 50 条
  • [42] Linear monitoring for cast-in-place reinforced concrete arch bridge construction
    ZHENG Yifeng
    Global Geology, 2012, 15 (02) : 145 - 150
  • [43] Impact of Cast-in-Place Concrete Column Construction Vibrations on Sensitive Occupancies
    Okumus, Pinar
    Oliva, Michael G.
    Hoehn, Tyler
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2015, 20 (01)
  • [44] Field load tests on plastic tube cast-in-place concrete piles
    Qi, Chang-Guang
    Chen, Yong-Hui
    Iskander, Magued
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-GROUND IMPROVEMENT, 2016, 169 (01) : 9 - 21
  • [45] Bond Characterization and Interfacial Coefficients at Precast UHPC and Cast-in-Place UHPC Interface
    Semendary, Ali A.
    Svecova, Dagmar
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2021, 33 (07)
  • [46] Experimental study on prevention of deterioration of bond strength between concrete and reinforcing bars in slurry for the construction of cast-in-place pile
    Fujii, Mamoru
    Watanabe, Ken
    Arai, Mauricio Jun
    Kondo, Jungo
    Katoh, Youiti
    PROCEEDINGS OF THE SIXTEENTH (2006) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 4, 2006, : 243 - +
  • [47] Cyclic Loading Test for Cast-in-Place Concrete-Filled Hollow Precast Concrete Columns
    Kim, Chang-Soo
    Lim, Woo-Young
    Park, Hong-Gun
    Oh, Jung-Keun
    ACI STRUCTURAL JOURNAL, 2016, 113 (02) : 205 - 215
  • [48] Cast-in-place cellulose fiber-reinforced cement paste, mortar, and concrete
    Rapoport, JR
    Shah, SR
    ACI MATERIALS JOURNAL, 2005, 102 (05) : 299 - 306
  • [49] PRECAST AND CAST-IN-PLACE CONCRETE USED TO SPEED HIGH-RISE CONSTRUCTION
    不详
    CONCRETE CONSTRUCTION, 1984, 29 (02): : 131 - &
  • [50] Effect of Fire Damage on Seismic Behavior of Cast-in-Place Reinforced Concrete Columns
    Demir U.
    Goksu C., Ph.d.
    Unal G., 0000-0001-5058-1382
    Green M., Ph.d., M.asce
    Ilki A., Ph.d.
    Journal of Structural Engineering (United States), 2020, 146 (11):