Effect of Fire Damage on Seismic Behavior of Cast-in-Place Reinforced Concrete Columns

被引:0
|
作者
Demir U. [1 ]
Goksu C., Ph.d. [2 ]
Unal G., 0000-0001-5058-1382 [3 ,4 ]
Green M., Ph.d., M.asce [5 ]
Ilki A., Ph.d. [1 ]
机构
[1] Civil Engineering Faculty, Istanbul Technical Univ., Istanbul
[2] Civil Engineering Faculty, Istanbul Technical Univ., Istanbul
[3] Earthquake Engineering and Disaster Management Institute, Istanbul Technical Univ., Istanbul
[4] Dept. of Civil Engineering, Faculty of Engineering, Erzincan Binali Yildirim Univ., Erzincan
[5] Faculty of Engineering and Applied Science, Queen's Univ., Kingston, K7L 3N6, ON
来源
关键词
Columns; Earthquake engineering; Fire; Reinforced concrete; Seismic;
D O I
10.1061/(ASCE)ST.1943-541X.0002794
中图分类号
学科分类号
摘要
This paper presents the results of an experimental study that was conducted to investigate the postfire seismic behavior of reinforced concrete columns. Five full-scale, flexure-critical code-complying (e.g., ACI 318-14) cast-in-place reinforced concrete columns were tested to failure under a constant axial load and reversed cyclic lateral displacements after being exposed to an ISO-834 standard fire for 30, 60, and 90 min. Other than the effects of the duration of the fire exposure, the effects of the thickness of the concrete cover (25 and 40 mm) on the structural performance was also investigated for the short fire exposure duration (30 min). The responses of the columns were analyzed in terms of lateral load-displacement relationships, ductility, stiffness, energy dissipation capacities, and residual displacements. The test results indicated that the fire exposure reduced the lateral load capacity of the columns, whereas the deformability capabilities were found to be satisfactory in terms of a structural response. It was also observed that the thickness of the concrete cover had only a slight influence on the postfire seismic behavior of the columns. Furthermore, a numerical study was conducted to predict the load-displacement response of the fire exposed columns. The comparison of the experimentally and numerically obtained load-displacement relationships indicated that the principles of structural mechanics usually applied to conventional columns are also valid for the columns exposed to fire. © 2020 American Society of Civil Engineers.
引用
收藏
相关论文
共 50 条
  • [1] Effect of Fire Damage on Seismic Behavior of Cast-in-Place Reinforced Concrete Columns
    Demir, Ugur
    Goksu, Caglar
    Unal, Goktug
    Green, Mark
    Ilki, Alper
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (11)
  • [2] Comparative study on the seismic performance of subway stations using reinforced concrete cast-in-place columns and truncated columns
    Ma, Chao
    Zhao, Yuanqi
    Dong, Huihui
    Lu, Dechun
    Du, Xiuli
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 169
  • [3] Seismic behavior of reinforced concrete frame substructure with cast-in-place slab on independent foundation
    Zhang, Wang-Xi
    Cai, Xiang-Dong
    Liu, Rui
    Xie, Hong-Tao
    Yi, Wei-Jian
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2022, 157
  • [4] Seismic Behavior of Hybrid Concrete Beam-Column Connections with Composite Beams and Cast-in-Place Columns
    Xue, Weichen
    Zhang, Bin
    [J]. ACI STRUCTURAL JOURNAL, 2014, 111 (03) : 617 - 627
  • [5] Seismic pullout behavior of cast-in-place anchor bolts embedded in plain concrete: Damage plasticity based analysis
    Shafei, Erfan
    Tariverdilo, Saeed
    [J]. STRUCTURES, 2021, 34 : 479 - 486
  • [6] Research on "Rotten Feet" Phenomenon in Cast-in-place Reinforced Concrete Columns of Liu Lu Apartment
    Zhao, Shouyong
    [J]. 2018 INTERNATIONAL CONFERENCE ON COMPUTER, CIVIL ENGINEERING AND MANAGEMENT SCIENCE (ICCEMS 2018), 2018, : 116 - 121
  • [7] Seismic Behavior of Cast-in-Place and Precast Recycled Aggregate Concrete Frames: A Comparative Study
    Xiao, Jianzhuang
    Ding, Tao
    Wang, Changqing
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2015, 25 (03) : 300 - 307
  • [8] Seismic Behaviors of Prefabricated Reinforced Concrete Shear Walls Assembled with a Cast-in-Place Vertical Joint
    Yang, Junna
    Yang, Yabin
    Deng, Lianchao
    Sun, Baoshan
    Gu, Zhongjia
    Zeng, Lingxin
    Zhao, Shunbo
    [J]. BUILDINGS, 2023, 13 (12)
  • [9] Seismic behavior of prefabricated alveolar type RC shear walls with cast-in-place embedded columns
    Zhang, Xizhi
    Han, Peng
    Li, Yilong
    Wang, Jincheng
    Ling, Guangrong
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 (08): : 88 - 94
  • [10] Experimental study on shear-flexural behavior of cast-in-place reinforced concrete piles
    Arai, Moto-o
    Yoshida, Makoto
    Yamamoto, Toshihiko
    Yamada, Kazuo
    [J]. Transactions of the Japan Concrete Institute, 2000, 22 : 287 - 292