Analysis and correction of field fluctuations in fMRI data using field monitoring

被引:29
|
作者
Bollmann, Saskia [1 ,2 ,7 ]
Kasper, Lars [1 ,2 ,3 ,4 ]
Vannesjo, S. Johanna [1 ,2 ,8 ]
Diaconescu, Andreea O. [3 ,4 ]
Dietrich, Benjamin E. [1 ,2 ]
Gross, Simon [1 ,2 ]
Stephan, Klaas E. [3 ,4 ,5 ,6 ]
Pruessmann, Klaas P. [1 ,2 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] Univ Zurich, CH-8092 Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, TNU, CH-8032 Zurich, Switzerland
[4] Swiss Fed Inst Technol, CH-8032 Zurich, Switzerland
[5] UCL, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
[6] Max Planck Inst Metab Res, D-50931 Cologne, Germany
[7] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld 4072, Australia
[8] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB Ctr, Oxford, England
关键词
fMRI; Echo-planar imaging; Field fluctuations; Physiological noise; SFNR; Magnetic field monitoring; INDEPENDENT COMPONENT ANALYSIS; INDUCED B-0 FLUCTUATIONS; STATIC MAGNETIC-FIELD; ECHO-PLANAR; HUMAN BRAIN; PHYSIOLOGICAL NOISE; RETROSPECTIVE CORRECTION; IMAGE-RECONSTRUCTION; SUBJECT MOTION; FUNCTIONAL MRI;
D O I
10.1016/j.neuroimage.2017.01.014
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This work investigates the role of magnetic field fluctuations as a confound in fMRI. In standard fMRI experiments with single-shot EPI acquisition at 3 Tesla the uniform and gradient components of the magnetic field were recorded with NMR field sensors. By principal component analysis it is found that differences of field evolution between the EPI readouts are explainable by few components relating to slow and within-shot field dynamics of hardware and physiological origin. The impact of fluctuating field components is studied by selective data correction and assessment of its influence on image fluctuation and SFNR. Physiological field fluctuations, attributed to breathing, were found to be small relative to those of hardware origin. The dominant confounds were hardware-related and attributable to magnet drift and thermal changes. In raw image time series, field fluctuation caused significant SFNR loss, reflected by a 67% gain upon correction. Large part of this correction can be accomplished by traditional image realignment, which addresses slow and spatially uniform field changes. With realignment, explicit field correction increased the SFNR on the order of 6%. In conclusion, field fluctuations are a relevant confound in fMRI and can be addressed effectively by retrospective data correction. Based on the physics involved it is anticipated that the advantage of full field correction increases with field strength, with non-Cartesian readouts, and upon phase-sensitive BOLD analysis.
引用
收藏
页码:92 / 105
页数:14
相关论文
共 50 条
  • [31] Study of electric field fluctuations using the Intercosmos-Bulgaria-1300 satellite data
    Stepanova, MV
    Antonova, EE
    Labbé, R
    Stanev, G
    Bankov, N
    Vucina, T
    Teltsov, MV
    Isaev, NV
    PLASMA PROCESSES IN THE NEAR-EARTH SPACE: INTERBALL AND BEYOND, 2003, 31 (05): : 1425 - 1430
  • [32] Logarithmic transformation for high-field BOLD fMRI data
    Scott M. Lewis
    Trenton A. Jerde
    Charidimos Tzagarakis
    Pavlos Gourtzelidis
    Maria-Alexandra Georgopoulos
    Nikolaos Tsekos
    Bagrat Amirikian
    Seong-Gi Kim
    Kâmil Uğurbil
    Apostolos P. Georgopoulos
    Experimental Brain Research, 2005, 165 : 447 - 453
  • [33] MEAN IONOSPHERIC FIELD CORRECTION FOR MAGSAT DATA
    YANAGISAWA, M
    KONO, M
    JOURNAL OF GEOPHYSICAL RESEARCH, 1985, 90 (NB3): : 2527 - 2536
  • [34] ERROR CORRECTION IN FIELD RECORDED SEISMIC DATA
    GALBRAITH, M
    MACMINN, CL
    GEOPHYSICS, 1982, 47 (08) : 1242 - 1242
  • [35] Baseline drift and physiological noise removal in high field fMRI data using kernel PCA
    Song, Xiaomu
    Ji, Tongyou
    Wyrwicz, Alice M.
    2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, : 441 - 444
  • [36] Correction for fluctuations of local molecular field in the Debye method of dilute solutions
    Bykov, AN
    Karabanov, SM
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2002, 75 (03) : 507 - 508
  • [37] Correction for fluctuations of local molecular field in the Debye method of dilute solutions
    Bykov, A.N.
    Karabanov, S.M.
    1600, Maik Nauka-Interperiodica Publishing (75):
  • [38] Correction for Fluctuations of Local Molecular Field in the Debye Method of Dilute Solutions
    A. N. Bykov
    S. M. Karabanov
    Russian Journal of Applied Chemistry, 2002, 75 : 507 - 508
  • [39] EVALUATION OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELD USING DATA PROVIDED BY THE NATIONAL AUTONOMOUS ELECTROMAGNETIC FIELD MONITORING SYSTEM
    Nedelcu, Marius-Nicușor
    Petrescu, Teodor
    UPB Scientific Bulletin, Series C: Electrical Engineering and Computer Science, 2023, 85 (02): : 175 - 184
  • [40] EVALUATION OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELD USING DATA PROVIDED BY THE NATIONAL AUTONOMOUS ELECTROMAGNETIC FIELD MONITORING SYSTEM
    Nedelcu, Marius- Nicusor
    Petrescu, Teodor
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2023, 85 (02): : 175 - 184