Microtube-based electrode arrays for low invasive extracellular recording with a high signal-to-noise ratio

被引:12
|
作者
Takei, Kuniharu [1 ]
Kawano, Takeshi [1 ]
Kawashima, Takahiro [2 ]
Sawada, Kazuaki [1 ]
Kaneko, Hidekazu [3 ]
Ishida, Makoto [1 ]
机构
[1] Toyohashi Univ Technol, Dept Elect & Elect Engn, Aichi 4418580, Japan
[2] Toyohashi Univ Technol, Dept Prod Syst Engn, Aichi 4418580, Japan
[3] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058566, Japan
基金
日本科学技术振兴机构;
关键词
Microtube; Microneedle; Array; Extracellular recording; Low invasiveness; High signal-to-noise ratio; METAL-OXIDE-SEMICONDUCTOR; MICROELECTRODE ARRAYS; BRAIN-TISSUE; SI(111); GROWTH; IMPROVEMENT; INTERFACES; DEVICES;
D O I
10.1007/s10544-009-9356-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report on the development of a microtube electrode array as a neural interface device. To combine the desired properties for the neural interface device, such as low invasiveness with a small needle and a good signal-to-noise ratio in neural recordings, we applied the structure of a glass pipette electrode to each microtube electrode. The device was fabricated as sub-5-mu m-diameter out-of-plane silicon dioxide microtube arrays using silicon microneedle templates, which are grown by the selective vapor-liquid-solid method. The microtubes had inner diameters of 1.9-6.4 mu m and a length of 25 mu m. Impedances ranged from 220 k Omega to 1.55 M Omega, which are less than those for conventional microneedles. In addition, the microtube electrodes had less signal attenuation than conventional microneedle electrodes. We confirmed that the effects of parasitic capacitances between neighboring microtubes and channels were sufficiently small using a test signal. Finally, neural responses evoked from a rat peripheral nerve were recorded in vivo using a microtube electrode to confirm that this type of electrode can be used for both electrophysiological measurements and as a neural interface device.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [41] Isotonic recalibration under a low signal-to-noise ratio
    Wuthrich, Mario V.
    Ziegel, Johanna
    SCANDINAVIAN ACTUARIAL JOURNAL, 2024, 2024 (03) : 279 - 299
  • [42] ACCURATE FREQUENCY ESTIMATION AT LOW SIGNAL-TO-NOISE RATIO
    KAY, SM
    IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1984, 32 (03): : 540 - 547
  • [43] Low signal-to-noise ratio underwater acoustic communications
    Yang, T. C.
    Yang, Wen-Bin
    SEA TECHNOLOGY, 2008, 49 (05) : 31 - +
  • [44] Sinusoidal frequency estimation at low signal-to-noise ratio
    Shyu, Wei-Ji
    Tsao, Jenho
    Journal of the Chinese Institute of Engineers, Transactions of the Chinese Institute of Engineers,Series A/Chung-kuo Kung Ch'eng Hsuch K'an, 1993, 16 (06): : 733 - 747
  • [45] Detection of the number of sources at low signal-to-noise ratio
    Gu, J.-F.
    Wei, P.
    Tai, H.-M.
    IET SIGNAL PROCESSING, 2007, 1 (01) : 2 - 8
  • [46] CALCULATION OF THE SIGNAL-TO-NOISE RATIO FOR SIMPLE SURFACE COILS AND ARRAYS OF COILS
    WANG, JM
    REYKOWSKI, A
    DICKAS, J
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (09) : 908 - 917
  • [47] Suprathreshold stochastic resonance and signal-to-noise ratio improvement in arrays of comparators
    Rousseau, D
    Chapeau-Blondeau, F
    PHYSICS LETTERS A, 2004, 321 (5-6) : 280 - 290
  • [48] Optimizing the signal-to-noise ratio in the measurement of photon pairs with detector arrays
    Lantz, Eric
    Moreau, Paul-Antoine
    Devaux, Fabrice
    PHYSICAL REVIEW A, 2014, 90 (06):
  • [49] A HIGH SIGNAL-TO-NOISE RATIO COMPOSITE QUASAR SPECTRUM
    FRANCIS, PJ
    HEWETT, PC
    FOLTZ, CB
    CHAFFEE, FH
    WEYMANN, RJ
    MORRIS, SL
    ASTROPHYSICAL JOURNAL, 1991, 373 (02): : 465 - 470
  • [50] Frequency Hopping Signal Detection in Low Signal-to-Noise Ratio Regimes
    Hasan, Md. Zoheb
    Couto, David J.
    Abdel-Malek, Mai A.
    Reed, Jeffrey H.
    2023 IEEE 34TH ANNUAL INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR AND MOBILE RADIO COMMUNICATIONS, PIMRC, 2023,