An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies

被引:2
|
作者
O'Doherty, Jim [1 ]
Schleyer, Paul [2 ]
机构
[1] Kings Coll London, PET Imaging Ctr, Div Imaging Sci & Biomed Engn, Kings Hlth Partners,St Thomas Hosp, 1st Floor,Lambeth Wing,Westminster Bridge Rd, London SE1 7EH, England
[2] Siemens Healthcare Ltd, Frimley, Camberley, England
来源
EJNMMI PHYSICS | 2017年 / 4卷
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
PET-MR; Attenuation correction; Cardiac PET; MYOCARDIAL-PERFUSION;
D O I
10.1186/s40658-017-0173-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Simultaneous cardiac perfusion studies are an increasing trend in PET-MR imaging. During dynamic PET imaging, the introduction of gadolinium-based MR contrast agents (GBCA) at high concentrations during a dual injection of GBCA and PET radiotracer may cause increased attenuation effects of the PET signal, and thus errors in quantification of PET images. We thus aimed to calculate the change in linear attenuation coefficient (LAC) of a mixture of PET radiotracer and increasing concentrations of GBCA in solution and furthermore, to investigate if this change in LAC produced a measurable effect on the image-based PET activity concentration when attenuation corrected by three different AC strategies. Findings: We performed simultaneous PET-MR imaging of a phantom in a static scenario using a fixed activity of 40 MBq [18 F]-NaF, water, and an increasing GBCA concentration from 0 to 66 mM (based on an assumed maximum possible concentration of GBCA in the left ventricle in a clinical study). This simulated a range of clinical concentrations of GBCA. We investigated two methods to calculate the LAC of the solution mixture at 511 keV: (1) a mathematical mixture rule and (2) CT imaging of each concentration step and subsequent conversion to LAC at 511 keV. This comparison showed that the ranges of LAC produced by both methods are equivalent with an increase in LAC of the mixed solution of approximately 2% over the range of 0-66 mM. We then employed three different attenuation correction methods to the PET data: (1) each PET scan at a specific millimolar concentration of GBCA corrected by its corresponding CT scan, (2) each PET scan corrected by a CT scan with no GBCA present (i.e., at 0 mM GBCA), and (3) a manually generated attenuation map, whereby all CT voxels in the phantom at 0 mM were replaced by LAC = 0.1 cm(-1). All attenuation correction methods (1-3) were accurate to the true measured activity concentration within 5%, and there were no trends in image-based activity concentrations upon increasing the GBCA concentration of the solution. (Continued on next page) Conclusion: The presence of high GBCA concentration (representing a worst-case scenario in dynamic cardiac studies) in solution with PET radiotracer produces a minimal effect on attenuation-corrected PET quantification.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] The effect of patient positioning aids on PET quantification in PET/MR imaging
    Frederic Mantlik
    Matthias Hofmann
    Matthias K. Werner
    Alexander Sauter
    Jürgen Kupferschläger
    Bernhard Schölkopf
    Bernd J. Pichler
    Thomas Beyer
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 920 - 929
  • [32] Simultaneous PET-MR First Pass Perfusion Imaging using a Novel Cardiac Perfusion Phantom
    Doherty, J. O.
    Sammut, E.
    Schleyer, P.
    Stirling, J.
    Marsden, P.
    Chiribiri, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S156 - S156
  • [33] Motion compensation for brain PET imaging using wireless MR active markers in simultaneous PET-MR: Phantom and non-human primate studies
    Huang, Chuan
    Ackerman, Jerome L.
    Petibon, Yoann
    Normandin, Marc D.
    Brady, Thomas J.
    El Fakhri, Georges
    Ouyang, Jinsong
    NEUROIMAGE, 2014, 91 : 129 - 137
  • [34] Effects of MR-Invisible Objects and Object Attenuation on PET Quantification in Small Animal PET/MR Imaging
    Bezrukov, Ilja
    Wehrl, Hans F.
    Liu, Chih-Chieh
    Hossain, Mosaddek
    Mantlik, Frederic
    Pichler, Bernd J.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [35] Feasibility of simultaneous PET-MR perfusion using a novel cardiac perfusion phantom
    O’Doherty J.
    Sammut E.
    Schleyer P.
    Stirling J.
    Nazir M.S.
    Marsden P.K.
    Chiribiri A.
    European Journal of Hybrid Imaging, 1 (1):
  • [36] Respiratory-resolved MR-based attenuation correction for motion-compensated cardiac PET-MR
    Kolbitsch, Christoph
    Neji, Radhouene
    Fenchel, Matthias
    Mallia, Andrew
    Marsden, Paul
    Schaeffter, Tobias
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (13):
  • [37] Optimization Of MR-Based Attenuation Correction For Cardiac PET/MR
    Vergani, V.
    Robson, P.
    Trivieri, M.
    Fayad, Z. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S699 - S700
  • [38] Effects of MR contrast agents on PET quantitation in PET-MRI study
    Lee, Wonho
    Park, Ji-Ae
    Kim, Kyeong Min
    Ko, In-Ok
    Lim, Ilhan
    Kim, Jin Su
    Kim, JongGuk
    Woo, Sang-Keun
    Kang, Joo Hyun
    Lim, Sang Moo
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [39] A human torso phantom study to evaluate motion correction strategies in hybrid PET-MR imaging
    Fieseler, Michael
    Koesters, Thomas
    Braun, Harald
    Quick, Harald
    Jiang, Xiaoyi
    Schaefers, Klaus
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [40] PET-MR Imaging in Evaluation of Cardiac and Paracardiac Masses With Histopathologic Correlation
    Yaddanapudi, Kavitha
    Brunken, Richard
    Tan, Carmela D.
    Rodriguez, E. Rene
    Bolen, Michael A.
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (01) : 82 - 85