Respiratory-resolved MR-based attenuation correction for motion-compensated cardiac PET-MR

被引:14
|
作者
Kolbitsch, Christoph [1 ,2 ,3 ]
Neji, Radhouene [4 ]
Fenchel, Matthias [5 ]
Mallia, Andrew [3 ]
Marsden, Paul [3 ]
Schaeffter, Tobias [1 ,2 ,3 ]
机构
[1] Phys Tech Bundesanstalt PTB, Braunschweig, Germany
[2] Phys Tech Bundesanstalt PTB, Berlin, Germany
[3] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
[4] Siemens Healthcare, MR Res Collaborat, Frimley, England
[5] Siemens Med Solut, MR R&D Collaborat, New York, NY USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 13期
基金
英国工程与自然科学研究理事会;
关键词
motion compensation; respiratory-resolved AC; simultaneous PET-MR; WHOLE-BODY PET/MRI; RECONSTRUCTION; OPTIMIZATION; ANGIOGRAPHY; ARTIFACTS; HEART; SCAN;
D O I
10.1088/1361-6560/aaca15
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion during cardiac PET acquisitions can cause image blurring and erroneous uptake quantification. In particular the misalignment of attenuation correction (AC) maps and PET emission data can lead to severe quantification errors, because the AC value of the heart is five times higher than of the surrounding lung tissue. Standard PET-MR approaches assume accurate alignment between breathhold MR-based AC maps and free-breathing PET emission data but cannot necessarily ensure it. Here we propose a 75 s free-breathing MR-acquisition, which provides respiratory-resolved AC maps (AC(Dyn)) and non-rigid respiratory motion information. This approach ensures accurate AC for free-breathing PET data and the motion information can be utilized to reduce image blurring caused by respiratory motion. 3D multi-echo MR data was acquired during a 75 s free-breathing scan in six patients. Both a respiratory-resolved dynamic AC map (AC(Dyn)) and a non-rigid respiratory motion field are provided by the MR scan. AC(Dyn) yielded AC values for different breathing phases ensuring accurate AC for each respiratory phase of the free-breathing PET data. In addition, motion-corrected image reconstruction (MCIR) of MR and PET data was used to minimize breathing artefacts. Motion amplitudes in the left ventricle were 8.2 +/- 2.9 mm with a dominant motion direction along the anterior-anterolateral and inferior-inferoseptal axis of the heart. The proposed AC(Dyn)-MCIR technique led to significant signal recovery of PET tracer uptake by 24 +/- 5% (p < 0.05). The maximum improvement was observed in patients with large misalignment between standard breathhold MR-based AC maps and PET emission data. PET image resolution was improved by 20 +/- 12% (p < 0.05). We have presented an efficient MR-scan, which ensures accurate motion information and AC values to improve PET quantification for cardiac PET-MR scans. The short scan time of 75 s makes this free-breathing acquisition easy to integrate into standard clinical PET-MR protocols.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] MR-Based Cardiac and Respiratory Motion-Compensation Techniques for PET-MR Imaging
    Munoz, Camila
    Kolbitsch, Christoph
    Reader, Andrew J.
    Marsden, Paul
    Schaeffter, Tobias
    Prieto, Claudia
    [J]. PET CLINICS, 2016, 11 (02) : 179 - 191
  • [2] MR-based motion compensation in simultaneous cardiac PET-MR
    Petibon, Yoann
    Ouyang, Jinsong
    Zhu, Xuping
    Reese, Timothy
    Dagher, Joseph
    Catana, Ciprian
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    Brady, Thomas
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling
    Robson, Philip M.
    Trivieri, MariaGiovanna
    Karakatsanis, Nicolas A.
    Padilla, Maria
    Abgral, Ronan
    Dweck, Marc R.
    Kovacic, Jason C.
    Fayad, Zahi A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (22):
  • [6] MR-based respiratory and cardiac motion correction for PET imaging
    Kuestner, Thomas
    Schwartz, Martin
    Martirosian, Petros
    Gatidis, Sergios
    Seith, Ferdinand
    Gilliam, Christopher
    Blu, Thierry
    Fayad, Hadi
    Visvikis, Dimitris
    Schick, F.
    Yang, B.
    Schmidt, H.
    Schwenzer, N. F.
    [J]. MEDICAL IMAGE ANALYSIS, 2017, 42 : 129 - 144
  • [7] Impact of MR-based PET motion correction on the quantification of PET kinetic parameters in simultaneous cardiac PET-MR
    Petibon, Yoann
    Ebrahimi, Behzad
    Reese, Timothy
    Guehl, Nicolas
    Normandin, Marc
    Alpert, Nathaniel
    El Fakhri, Georges
    Ouyang, Jinsong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [8] Optimization Of MR-Based Attenuation Correction For Cardiac PET/MR
    Vergani, V.
    Robson, P.
    Trivieri, M.
    Fayad, Z. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S699 - S700
  • [9] Optimized respiratory-resolved motion-compensated 3D Cartesian coronary MR angiography
    Correia, Teresa
    Ginami, Giulia
    Cruz, Gastao
    Neji, Radhouene
    Rashid, Imran
    Botnar, Rene M.
    Prieto, Claudia
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2618 - 2629
  • [10] 4D tagged MR-based motion correction in simultaneous PET-MR
    Chun, Se Young
    Reese, Timothy
    Guerin, Bastien
    Zhu, Xuping
    Cho, Sanghee
    Ouyang, Jinsong
    Catana, Ciprian
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51