Respiratory-resolved MR-based attenuation correction for motion-compensated cardiac PET-MR

被引:14
|
作者
Kolbitsch, Christoph [1 ,2 ,3 ]
Neji, Radhouene [4 ]
Fenchel, Matthias [5 ]
Mallia, Andrew [3 ]
Marsden, Paul [3 ]
Schaeffter, Tobias [1 ,2 ,3 ]
机构
[1] Phys Tech Bundesanstalt PTB, Braunschweig, Germany
[2] Phys Tech Bundesanstalt PTB, Berlin, Germany
[3] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
[4] Siemens Healthcare, MR Res Collaborat, Frimley, England
[5] Siemens Med Solut, MR R&D Collaborat, New York, NY USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 13期
基金
英国工程与自然科学研究理事会;
关键词
motion compensation; respiratory-resolved AC; simultaneous PET-MR; WHOLE-BODY PET/MRI; RECONSTRUCTION; OPTIMIZATION; ANGIOGRAPHY; ARTIFACTS; HEART; SCAN;
D O I
10.1088/1361-6560/aaca15
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion during cardiac PET acquisitions can cause image blurring and erroneous uptake quantification. In particular the misalignment of attenuation correction (AC) maps and PET emission data can lead to severe quantification errors, because the AC value of the heart is five times higher than of the surrounding lung tissue. Standard PET-MR approaches assume accurate alignment between breathhold MR-based AC maps and free-breathing PET emission data but cannot necessarily ensure it. Here we propose a 75 s free-breathing MR-acquisition, which provides respiratory-resolved AC maps (AC(Dyn)) and non-rigid respiratory motion information. This approach ensures accurate AC for free-breathing PET data and the motion information can be utilized to reduce image blurring caused by respiratory motion. 3D multi-echo MR data was acquired during a 75 s free-breathing scan in six patients. Both a respiratory-resolved dynamic AC map (AC(Dyn)) and a non-rigid respiratory motion field are provided by the MR scan. AC(Dyn) yielded AC values for different breathing phases ensuring accurate AC for each respiratory phase of the free-breathing PET data. In addition, motion-corrected image reconstruction (MCIR) of MR and PET data was used to minimize breathing artefacts. Motion amplitudes in the left ventricle were 8.2 +/- 2.9 mm with a dominant motion direction along the anterior-anterolateral and inferior-inferoseptal axis of the heart. The proposed AC(Dyn)-MCIR technique led to significant signal recovery of PET tracer uptake by 24 +/- 5% (p < 0.05). The maximum improvement was observed in patients with large misalignment between standard breathhold MR-based AC maps and PET emission data. PET image resolution was improved by 20 +/- 12% (p < 0.05). We have presented an efficient MR-scan, which ensures accurate motion information and AC values to improve PET quantification for cardiac PET-MR scans. The short scan time of 75 s makes this free-breathing acquisition easy to integrate into standard clinical PET-MR protocols.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Accelerated MR-Based Motion Field Measurement for PET Motion Correction in PET/MR
    Han, Paul
    Djebra, Yanis
    Petibon, Yoann
    Marin, Thibault
    Ouyang, Jinsong
    El Fakhri, Georges
    Ma, Chao
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [22] Joint PET-MR respiratory motion models for clinical PET motion correction
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Wan, Simon
    McClelland, Jamie
    Barnes, Anna
    Arridge, Simon
    Ourselin, Sebastien
    Atkinson, David
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (17): : 6515 - 6530
  • [23] Lung cancer imaging with respiratory motion-compensated simultaneous PET/MR
    Dutta, Joyita
    El Fakhri, Georges
    Li, Quanzheng
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [24] Respiratory motion correction in cardiac PET-MR by optical monitoring and incorporation of MRI data
    Boutchko, Rostyslav
    Saloner, David
    Gullberg, Grant
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [25] A review of PET attenuation correction methods for PET-MR
    Georgios Krokos
    Jane MacKewn
    Joel Dunn
    Paul Marsden
    [J]. EJNMMI Physics, 10
  • [26] Errors in MR-based attenuation correction for brain imaging with PET/MR scanners
    Kops, Elena Rota
    Herzog, Hans
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 104 - 107
  • [27] MR-based Attenuation Correction for Whole-body PET/MR System
    Hu, Z.
    Renisch, S.
    Schweizer, B.
    Blaffert, T.
    Ojha, N.
    Guo, T.
    Tang, J.
    Tung, C.
    Kaste, J.
    Schulz, V.
    Torres, I.
    Shao, L.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2119 - 2122
  • [28] Influence and Compensation of Truncation Artifacts in MR-Based Attenuation Correction in PET/MR
    Schramm, G.
    Langner, J.
    Hofheinz, F.
    Petr, J.
    Lougovski, A.
    Beuthien-Baumann, B.
    Platzek, I.
    van den Hoff, J.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (11) : 2056 - 2063
  • [29] A review of PET attenuation correction methods for PET-MR
    Krokos, Georgios
    Mackewn, Jane
    Dunn, Joel
    Marsden, Paul
    [J]. EJNMMI PHYSICS, 2023, 10 (01)
  • [30] MR-based motion correction for cardiac PET parametric imaging: a simulation study
    Rong Guo
    Yoann Petibon
    Yixin Ma
    Georges El Fakhri
    Kui Ying
    Jinsong Ouyang
    [J]. EJNMMI Physics, 5