Selective and Sensitive Chemiluminescence Determination of MCPB: Flow Injection and Liquid Chromatography

被引:5
|
作者
Meseguer-Lloret, Susana [1 ]
Torres-Cartas, Sagrario [1 ]
Catala-Icardo, Monica [1 ]
Gomez-Benito, Carmen [1 ]
机构
[1] Univ Politecn Valencia, Inst Invest Gest Integrada Zonas Costeras, E-46022 Valencia, Spain
关键词
MCPB; Flow injection; Liquid chromatography; High-performance liquid chromatography; HPLC; Chemiluminescence; Photoreactor; Solid phase extraction; SPE; SOLID-PHASE EXTRACTION; CHLOROPHENOXY ACID HERBICIDES; DIODE-ARRAY DETECTION; GC-MS ANALYSIS; PHOTOINDUCED CHEMILUMINESCENCE; WATER SAMPLES; POSTCOLUMN CHEMILUMINESCENCE; PHENOXYACID HERBICIDES; ENVIRONMENTAL WATERS; AQUEOUS SAMPLES;
D O I
10.1177/0003702815620133
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two new chemiluminescence (CL) methods are described for the determination of the herbicide 4-(4-chloro-o-tolyloxy) butyric acid (MCPB). First, a flow injection chemiluminescence (FI-CL) method is proposed. In this method, MCPB is photodegraded with an ultraviolet (UV) lamp and the photoproducts formed provide a great CL signal when they react with ferricyanide in basic medium. Second, a high-performance liquid chromatography chemiluminescence (HPLC-CL) method is proposed. In this method, before the photodegradation and CL reaction, the MCPB and other phenoxyacid herbicides are separated in a C18 column. The experimental conditions for the FI-CL and HPLC-CL methods are optimized. Both methods present good sensitivity, the detection limits being 0.12 mu g L-1 and 0.1 mu g L-1 (for FI-CL and HPLC-CL, respectively) when solid phase extraction (SPE) is applied. Intra-and interday relative standard deviations are below 9.9%. The methods have been satisfactorily applied to the analysis of natural water samples. FI-CL method can be employed for the determination of MCPB in simple water samples and for the screening of complex water samples in a fast, economic, and simple way. The HPLC-CL method is more selective, and allows samples that have not been resolved with the FI-CL method to be solved.
引用
收藏
页码:312 / 321
页数:10
相关论文
共 50 条
  • [41] A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection
    Alam, Seikh Mafiz
    Jeon, Chi Wan
    Karim, Mohammad Mainul
    Lee, Sang Hak
    Wabaidur, Saikh Mohammad
    Suh, Yeoun Suk
    Chung, Hye Young
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (01): : 102 - 106
  • [42] Determination of Enoxacin in Tablet by Flow Injection Chemiluminescence
    Ren Nailin
    Yang Chi
    ADVANCES IN CHEMISTRY RESEARCH II, PTS 1-3, 2012, 554-556 : 1880 - 1883
  • [43] Determination of oxytetracycline by flow injection with chemiluminescence detection
    Guo, LQ
    Xie, ZH
    Bian, XT
    Lin, XC
    Zhang, WL
    Liu, XH
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 129 - 134
  • [44] Direct flow injection chemiluminescence determination of salicylamide
    Mestre, YF
    Zamora, LL
    Calatayud, JM
    ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) : 159 - 163
  • [45] Determination of propranolol hydrochloride by flow injection chemiluminescence
    Rao, ZM
    Wu, QL
    Xie, GP
    Xu, HH
    Zhang, XQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1660 - 1662
  • [46] A flow injection chemiluminescence system for the determination of isoniazid
    Huang, YM
    Zhang, ZJ
    Zhang, DJ
    Lv, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04): : 429 - 431
  • [47] Determination of nimodipine by flow injection chemiluminescence method
    Zhao, YJ
    Lang, HY
    Zhang, XJ
    Jiang, YR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (03) : 345 - 347
  • [48] Determination of norfloxacin by flow injection electrogenerated chemiluminescence
    Ma, HY
    Zheng, XW
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 857 - 860
  • [49] Reverse flow injection chemiluminescence determination of glyphosate
    Fan, S.L.
    Lu, C.
    Gao, J.L.
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2001, 37 (07):
  • [50] Flow-injection Chemiluminescence Determination of Catecholamines
    Cheng Xiao ZHANG
    Zhu Jun ZHANG(Department of Chemistry
    (Lu’an Teacher’s College
    ChineseChemicalLetters, 1998, (09) : 843 - 845