Selective and Sensitive Chemiluminescence Determination of MCPB: Flow Injection and Liquid Chromatography

被引:5
|
作者
Meseguer-Lloret, Susana [1 ]
Torres-Cartas, Sagrario [1 ]
Catala-Icardo, Monica [1 ]
Gomez-Benito, Carmen [1 ]
机构
[1] Univ Politecn Valencia, Inst Invest Gest Integrada Zonas Costeras, E-46022 Valencia, Spain
关键词
MCPB; Flow injection; Liquid chromatography; High-performance liquid chromatography; HPLC; Chemiluminescence; Photoreactor; Solid phase extraction; SPE; SOLID-PHASE EXTRACTION; CHLOROPHENOXY ACID HERBICIDES; DIODE-ARRAY DETECTION; GC-MS ANALYSIS; PHOTOINDUCED CHEMILUMINESCENCE; WATER SAMPLES; POSTCOLUMN CHEMILUMINESCENCE; PHENOXYACID HERBICIDES; ENVIRONMENTAL WATERS; AQUEOUS SAMPLES;
D O I
10.1177/0003702815620133
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two new chemiluminescence (CL) methods are described for the determination of the herbicide 4-(4-chloro-o-tolyloxy) butyric acid (MCPB). First, a flow injection chemiluminescence (FI-CL) method is proposed. In this method, MCPB is photodegraded with an ultraviolet (UV) lamp and the photoproducts formed provide a great CL signal when they react with ferricyanide in basic medium. Second, a high-performance liquid chromatography chemiluminescence (HPLC-CL) method is proposed. In this method, before the photodegradation and CL reaction, the MCPB and other phenoxyacid herbicides are separated in a C18 column. The experimental conditions for the FI-CL and HPLC-CL methods are optimized. Both methods present good sensitivity, the detection limits being 0.12 mu g L-1 and 0.1 mu g L-1 (for FI-CL and HPLC-CL, respectively) when solid phase extraction (SPE) is applied. Intra-and interday relative standard deviations are below 9.9%. The methods have been satisfactorily applied to the analysis of natural water samples. FI-CL method can be employed for the determination of MCPB in simple water samples and for the screening of complex water samples in a fast, economic, and simple way. The HPLC-CL method is more selective, and allows samples that have not been resolved with the FI-CL method to be solved.
引用
收藏
页码:312 / 321
页数:10
相关论文
共 50 条
  • [21] Flow injection chemiluminescence determination of tetracycline
    Townshend, A
    Ruengsitagoon, W
    Thongpoon, C
    Liawruangrath, S
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 105 - 111
  • [22] Flow injection/chemiluminescence determination of cephradine
    Fan, SL
    Lü, C
    Zhou, QX
    Wang, J
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (03) : 367 - 367
  • [23] Flow injection chemiluminescence determination of paracetamol
    Ruengsitagoon, Wirat
    Liawruangrath, Saisunee
    Townshend, Alan
    TALANTA, 2006, 69 (04) : 976 - 983
  • [24] Determination of hydrazine by flow injection with chemiluminescence
    Lv, JG
    Huang, YM
    Zhang, ZJ
    ANALYTICAL LETTERS, 2001, 34 (08) : 1323 - 1330
  • [25] Chemiluminescence flow injection determination of bismuth
    Baezzat, Mohammad R.
    Bahrani, Roza
    LUMINESCENCE, 2010, 25 (02) : 106 - 106
  • [26] Flow injection chemiluminescence determination of pyrogallol
    Safavi, A
    Baezzat, MR
    ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) : 113 - 116
  • [27] Flow injection chemiluminescence determination of medazepam
    S. M. Sultan
    Ala’ddin M. Almuaibed
    A. Townshend
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 167 - 169
  • [28] Flow injection chemiluminescence determination of tetracyclines
    Li, Z
    Feng, ML
    Lu, JR
    Gong, ZL
    Jiang, HL
    ANALYTICAL LETTERS, 1997, 30 (04) : 797 - 807
  • [29] Determination of ribavirin by flow injection chemiluminescence
    Juqing Jin1
    2School of Medicine
    3Pharmacy Faculty of Fujian Medical University
    JournalofNanjingMedicalUniversity, 2006, (05) : 266 - 270
  • [30] Flow injection chemiluminescence determination of medazepam
    Sultan, SM
    Almuaibed, AM
    Townshend, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (01): : 167 - 169