A hybrid process for leachate wastewater treatment: Evaporation and reverse osmosis/sequencing batch reactor

被引:9
|
作者
Bouchareb, Raouf [1 ]
Isik, Zelal [2 ]
Ozay, Yasin [3 ]
Karagunduz, Ahmet [4 ]
Keskinler, Bulent [4 ]
Dizge, Nadir [2 ]
机构
[1] Saleh Boubnider Univ, Proc Engn Fac, Dept Environm Engn, Constantine, Algeria
[2] Mersin Univ, Dept Environm Engn, TR-33343 Mersin, Turkey
[3] Tarsus Univ, Vocat Sch Tech Sci Mersin Tarsus Organized Ind Zo, Dept Environm Protect Technol, Mersin, Turkey
[4] Gebze Tech Univ, Dept Environm Engn, Kocaeli, Turkey
关键词
biological treatment; evaporation; leachate; reverse osmosis membrane; LANDFILL LEACHATE; BIOLOGICAL TREATMENT; RECIRCULATION; REMOVAL;
D O I
10.1002/wer.10717
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a hybrid process for leachate wastewater treatment including evaporation and reverse osmosis (RO) membrane or biological treatment systems was suggested. Experiments were performed on a real landfill leachate wastewater. The leachate was subjected to evaporation; as a result, a distillate was obtained containing less organic matter and less substantial amounts of other pollutants, as ammonium salts and total phenols were removed. Tests were carried out at different evaporation temperatures and times. The initial leachate pH was adjusted and optimized. For optimum conditions, each of chemical oxygen demand (COD), total phenol, and ammonium salt concentrations were reduced to 99.99%, 95.00%, and 83.00%, respectively. The distillate of the first stage of the proposed process was then exposed to RO membrane system, as a first study, under different transmembrane pressure of 20, 30, and 40 bar and at different pH values of 7, 8, and 9. As a second suggested treatment system, the distillate was subjected to a biological treatment process for 30 days as a retention time, pH = 6, and room temperature 25 degrees C +/- 1 degrees C. At the end of the research study, a comparison was conducted between results obtained with RO membrane separation and biological treatment system as two distinct treatment systems proposed for leachate landfill wastewater treatment. Although both systems were effective for landfill leachate wastewater treatment, however, with the RO membrane separation system, COD removal efficiency reached 99.99%. In the other hand, with biological treatment process, COD elimination was as much as 90.00%. Certainly, evaporation and RO are not novel ways of landfill leachate treatment; however, few studies have attempted to use similar combined system for landfill leachate wastewater treatment and attained effective results of treated water. Practitioner Points A hybrid process of evaporation and RO membrane or biological treatment systems was suggested for leachate wastewater treatment. For optimum conditions, COD, total phenols, and ammonium salt reductions were achieved to 99.99%, 95%, and 83%, respectively, after the first evaporation stage. The distillate of the first stage of the proposed process was then exposed to RO membrane system and biological treatment system. Different transmembrane pressure and different pH values were optimized for RO.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Treatment of tannery wastewater in a sequencing batch reactor
    Carucci, A
    Chiavola, A
    Majone, M
    Rolle, E
    WATER SCIENCE AND TECHNOLOGY, 1999, 40 (01) : 253 - 259
  • [12] Applicability of the sequencing batch reactor for wastewater treatment
    Mazumder, D
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2002, 17 (03) : 255 - 265
  • [13] Treatment of wastewater using a sequencing batch reactor
    de Sousa, Jose Tavares
    Mina, Vanessa Gomes
    Lopes, Wilton Silva
    Leite, Valderi Duarte
    de Oliveira, Marielle Ferreira
    ENVIRONMENTAL TECHNOLOGY, 2013, 34 (08) : 1035 - 1042
  • [14] A comparative study of sequencing batch reactor and movingbed sequencing batch reactor for piggery wastewater treatment
    Sombatsompop, Kwannate
    Songpim, Anusak
    Reabroi, Sillapa
    Inkong-ngam, Prapatpong
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2011, 5 (02) : 191 - 203
  • [15] Optimisation of sanitary landfill leachate treatment in a sequencing batch reactor
    Spagni, A.
    Marsili-Libelli, S.
    Lavagnolo, M. C.
    WATER SCIENCE AND TECHNOLOGY, 2008, 58 (02) : 337 - 343
  • [16] Application of a membrane sequencing batch reactor for landfill leachate treatment
    Tsilogeorgis, J.
    Zouboulis, A.
    Samaras, P.
    Zambouhs, D.
    DESALINATION, 2008, 221 (1-3) : 483 - 493
  • [17] Impact of salinity on treatment of saline wastewater by sequencing batch biofilm reactor process
    Lu Jie
    Yan Xue
    Ma Yan-fei
    Tian Cai-xing
    Ding Jin-cheng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2014, 21 (05) : 1989 - 1994
  • [18] Landfill leachate treatment with sequencing batch reactor and membrane bioreactor
    Laitinen, Niina
    Luonsi, Antero
    Vilen, Jari
    DESALINATION, 2006, 191 (1-3) : 86 - 91
  • [19] Impact of salinity on treatment of saline wastewater by sequencing batch biofilm reactor process
    Jie Lu
    Xue Yan
    Yan-fei Ma
    Cai-xing Tian
    Jin-cheng Ding
    Journal of Central South University, 2014, 21 : 1989 - 1994
  • [20] Impact of salinity on treatment of saline wastewater by sequencing batch biofilm reactor process
    卢杰
    闫雪
    马艳飞
    田彩星
    丁金城
    JournalofCentralSouthUniversity, 2014, 21 (05) : 1989 - 1994