Excimer laser tissue interactions in the cornea

被引:6
|
作者
Vinciguerra, Riccardo [1 ,2 ]
Borgia, Alfredo [3 ]
Tredici, Costanza [4 ]
Vinciguerra, Paolo [3 ,4 ]
机构
[1] Humanitas San Pio X Hosp, Milan, Italy
[2] Univ Liverpool, Sch Engn, Liverpool, Merseyside, England
[3] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20090 Pieve Emanuele Milan, Italy
[4] IRCCS, Humanitas Clin & Res Ctr, Via Manzoni 56, I-20089 Rozzano, MI, Italy
关键词
Humanitas san pio X hospital; Via francesco nava 31; Milan; Italy; cornea; excimer laser; biomechanics; regression; IN-SITU KERATOMILEUSIS; INCISION LENTICULE EXTRACTION; CLINICAL FOLLOW-UP; PHOTOREFRACTIVE KERATECTOMY; REFRACTIVE SURGERY; PHOTOTHERAPEUTIC KERATECTOMY; BIOMECHANICAL PROPERTIES; INTRAOCULAR-PRESSURE; RESPONSE PARAMETERS; STROMAL THICKNESS;
D O I
10.1016/j.exer.2021.108537
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Excimer lasers induces significant changes to corneal structure and corneal biomechanics. The aim of this paper is to describe all laser-tissue interactions which are relevant for clinical practice, particularly, we will focus on laser ablations profiles, causes of regression and haze and prevention of those. At last the manuscript will describe the impact on corneal biomechanics of different Laser Vision Corrections techniques.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] EFFECT OF EXCIMER-LASER KERATECTOMY ON THE CORNEA OF THE DEVELOPING CHICK
    WYEDVORAK, J
    FOULDS, WS
    CHAN, WK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1800 - 1800
  • [22] HIGH-SPEED PHOTOGRAPHY OF EXCIMER LASER ABLATION OF THE CORNEA
    PULIAFITO, CA
    STERN, D
    KRUEGER, RR
    MANDEL, ER
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (09) : 1255 - 1259
  • [23] OBJECTIVE MEASUREMENTS OF HAZE FOLLOWING EXCIMER LASER ABLATION OF CORNEA
    MCCALLY, RL
    HOCHHEIMER, BF
    CONNOLLY, PJ
    CHAMON, W
    AZAR, DT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 802 - 802
  • [24] CORNEAL ENDOTHELIAL INJURY FOLLOWING EXCIMER LASER ABLATION OF THE CORNEA
    DEHM, E
    PULIAFITO, CA
    ADLER, C
    STEINERT, RF
    LASERS IN SURGERY AND MEDICINE, 1986, 6 (02) : 241 - 241
  • [25] Excimer laser ablated cornea observed by atomic force microscopy
    Lydataki, S
    Lesniewska, E
    Tsilimbaris, MK
    Panagopoulou, S
    Le Grimellec, C
    Pallikaris, IG
    SINGLE MOLECULES, 2002, 3 (2-3) : 141 - 147
  • [26] DEPENDENCE OF THE ABLATION RATE ON LASER PARAMETERS IN EXCIMER-LASER SURGERY OF THE CORNEA
    FORSTER, W
    RATKAY, I
    DERHEIDE, KA
    GRUCHMANN, T
    PETZELT, Y
    DANGEL, P
    GRENZEBACH, U
    GERDING, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S1063 - S1063
  • [27] Excimer laser interactions with an aluminum alloy
    Koutsomichalis, A
    Kefalidou, A
    JOURNAL OF LASER APPLICATIONS, 1996, 8 (05) : 247 - 250
  • [28] ULTRASOUND BIOMICROSCOPIC ASSESSMENT OF THE CORNEA FOLLOWING EXCIMER-LASER PHOTOKERATECTOMY
    PAVLIN, CJ
    HARASIEWICZ, K
    FOSTER, FS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 : 206 - 211
  • [29] Immunohistochemical changes of rabbit cornea after excimer laser surface ablation
    Kwak, CY
    Lee, JH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4633 - 4633
  • [30] Intraocular measurements of pressure transients induced by excimer laser ablation of the cornea
    Siano, S
    Pini, R
    Gobbi, PG
    Salimbeni, R
    Vannini, M
    Carones, F
    Trabucchi, G
    Brancato, R
    LASERS IN SURGERY AND MEDICINE, 1997, 20 (04) : 416 - 425