Intraocular measurements of pressure transients induced by excimer laser ablation of the cornea

被引:0
|
作者
Siano, S
Pini, R
Gobbi, PG
Salimbeni, R
Vannini, M
Carones, F
Trabucchi, G
Brancato, R
机构
[1] CNR,INST QUANTUM ELECT,I-50127 FLORENCE,ITALY
[2] UNIV MILAN,SAN RAFFAELE SCI INST,DEPT OPHTHALMOL & VISUAL SCI,I-20132 MILAN,ITALY
关键词
argon-fluoride laser; photoacoustic waves; PRK;
D O I
暂无
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objective: The evolution of pressure waves induced by argon-fluoride laser ablation of the cornea in the typical operative conditions of clinical laser keratectomy has been studied experimentally and analyzed. Materials and Methods: Freshly enucleated porcine eyes were irradiated at a laser fluence of 180 mJ/cm(2) with various spot diameters in the range 1-6.5 mm. Pressure transients were detected by a fast rise time needle hydrophone inserted into the eyeball from the posterior pole and moved along the eye optical axis toward the cornea. Results: Pressure peaks as high as 90 bar and of 50 ns pulse duration (FWHM) were measured in the anterior chamber. Observation of the pulse shape evolution during propagation put in evidence the onset of a marked rarefaction phase following the compressional spike, with intense negative peaks (up to -40 bar) located at increasing distances from the corneal surface for increasing spot diameters. Conclusions: This behavior was explained by means of simplified models describing pressure pulse generation and diffraction effects occurring during its propagation. Implications to clinical procedures, as possible damages due to tissue stretching and cavitation formation, are also discussed. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:416 / 425
页数:10
相关论文
共 50 条
  • [1] OBJECTIVE MEASUREMENTS OF HAZE FOLLOWING EXCIMER LASER ABLATION OF CORNEA
    MCCALLY, RL
    HOCHHEIMER, BF
    CONNOLLY, PJ
    CHAMON, W
    AZAR, DT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 802 - 802
  • [2] Imaging of acoustic waves induced by excimer laser ablation of the cornea
    Rossi, F
    Pini, R
    Siano, S
    Salimbeni, R
    LASERS IN OPHTHALMOLOGY IV, PROCEEDINGS OF, 1996, 2930 : 58 - 62
  • [3] EXCIMER-LASER ABLATION OF THE CORNEA
    PETTIT, GH
    EDIGER, MN
    WEIBLINGER, RP
    OPTICAL ENGINEERING, 1995, 34 (03) : 661 - 667
  • [4] Independent study of excimer laser ablation of the cornea
    Jory, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (07): : 970 - 971
  • [5] Temperature monitoring by infrared radiation measurements during ArF excimer laser ablation with cornea
    Ishihara, M
    Arai, T
    Sato, S
    Nakano, H
    Obara, M
    Kikuchi, M
    LASER-TISSUE INTERACTION X: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, PROCEEDINGS OF, 1999, 3601 : 335 - 339
  • [6] EXCIMER LASER ABLATION OF THE CORNEA AND LENS - EXPERIMENTAL STUDIES
    PULIAFITO, CA
    STEINERT, RF
    DEUTSCH, TF
    HILLENKAMP, F
    DEHM, EJ
    ADLER, CM
    OPHTHALMOLOGY, 1985, 92 (06) : 741 - 748
  • [7] PHYSICAL PROBLEMS OF EXCIMER-LASER CORNEA ABLATION
    BOR, Z
    HOPP, B
    RACZ, B
    SZABO, G
    MARTON, Z
    RATKAY, I
    MOHAY, J
    SUVEGES, I
    FUST, A
    OPTICAL ENGINEERING, 1993, 32 (10) : 2481 - 2486
  • [8] Acoustic focusing associated with excimer laser ablation of the cornea
    Siano, S
    Pini, R
    Rossi, F
    Salimbeni, R
    Gobbi, PG
    APPLIED PHYSICS LETTERS, 1998, 72 (06) : 647 - 649
  • [9] Alternatives to excimer laser refractive surgery: UV and mid-infrared laser ablation of intraocular lenses and porcine cornea
    Serafetinides, A. A.
    Makropoulou, M.
    Spyratou, E.
    Bacharis, C.
    14TH INTERNATIONAL SCHOOL ON QUANTUM ELECTRONICS: LASER PHYSICS AND APPLICATIONS, 2007, 6604
  • [10] PEAK PRESSURE AND TEMPERATURE-MEASUREMENTS AT UV LASER ABLATION OF THE CORNEA
    BEYLIN, EN
    DMITRIEV, AK
    LEKHTSIER, EN
    ORLOV, MY
    SEMYENOV, AD
    TYURIN, VS
    FURZIKOV, NP
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1990, 54 (08): : 1581 - 1585