Intraocular measurements of pressure transients induced by excimer laser ablation of the cornea

被引:0
|
作者
Siano, S
Pini, R
Gobbi, PG
Salimbeni, R
Vannini, M
Carones, F
Trabucchi, G
Brancato, R
机构
[1] CNR,INST QUANTUM ELECT,I-50127 FLORENCE,ITALY
[2] UNIV MILAN,SAN RAFFAELE SCI INST,DEPT OPHTHALMOL & VISUAL SCI,I-20132 MILAN,ITALY
关键词
argon-fluoride laser; photoacoustic waves; PRK;
D O I
暂无
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objective: The evolution of pressure waves induced by argon-fluoride laser ablation of the cornea in the typical operative conditions of clinical laser keratectomy has been studied experimentally and analyzed. Materials and Methods: Freshly enucleated porcine eyes were irradiated at a laser fluence of 180 mJ/cm(2) with various spot diameters in the range 1-6.5 mm. Pressure transients were detected by a fast rise time needle hydrophone inserted into the eyeball from the posterior pole and moved along the eye optical axis toward the cornea. Results: Pressure peaks as high as 90 bar and of 50 ns pulse duration (FWHM) were measured in the anterior chamber. Observation of the pulse shape evolution during propagation put in evidence the onset of a marked rarefaction phase following the compressional spike, with intense negative peaks (up to -40 bar) located at increasing distances from the corneal surface for increasing spot diameters. Conclusions: This behavior was explained by means of simplified models describing pressure pulse generation and diffraction effects occurring during its propagation. Implications to clinical procedures, as possible damages due to tissue stretching and cavitation formation, are also discussed. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:416 / 425
页数:10
相关论文
共 50 条
  • [31] Evaluation of the Efficacy of Excimer Laser Ablation of Cross-Linked Porcine Cornea
    Chen, Shihao
    Li, Yini
    Stojanovic, Aleksander
    Zhang, Jia
    Wang, Yibo
    Wang, Qinmei
    Seiler, Theo
    PLOS ONE, 2012, 7 (10):
  • [32] UNSCHEDULED DNA-SYNTHESIS FOLLOWING EXCIMER LASER ABLATION OF THE CORNEA INVIVO
    NUSS, RC
    PULIAFITO, CA
    DEHM, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1987, 28 (02) : 287 - 294
  • [33] EXCIMER-LASER-INDUCED FLUORESCENCE OF RABBIT CORNEA - RADIOMETRIC MEASUREMENT THROUGH THE CORNEA
    EDIGER, MN
    LASERS IN SURGERY AND MEDICINE, 1991, 11 (02) : 93 - 98
  • [35] Intraocular pressure after excimer laser myopic refractive surgery
    Montés-Micó, R
    Charman, WN
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2001, 21 (03) : 228 - 235
  • [36] Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy
    Abbasoglu, KE
    Bowman, RW
    Cavanagh, HD
    McCulley, JP
    OPHTHALMOLOGY, 1998, 105 (12) : 2193 - 2196
  • [37] Cornea, intraocular pressure and glaucoma
    Myers, JS
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (02): : 100 - 101
  • [38] Does tissue temperature influence pseudomembrane formation after excimer laser ablation of the cornea
    Lee, RF
    Seitz, B
    deOliveira, CBR
    Moreira, LB
    Barron, E
    McDonnell, PJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 283 - 283
  • [39] Determination of excimer laser ablation rate of the human cornea using in vivo Scheimpflug videography
    Huebscher, HJ
    Genth, U
    Seiler, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (01) : 42 - 46
  • [40] BIMODAL RESPONSE IN HAZE SEVERITY FOLLOWING PHOTOTHERAPEUTIC EXCIMER-LASER ABLATION OF CORNEA
    MCCALLY, RL
    CONNOLLY, PJ
    JAIN, S
    STARK, WJ
    AZAR, DT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1299 - 1299