A Method to Improve the Accuracy of the Bioelectrical Impedance Phase-Angle Measuring System

被引:0
|
作者
Nguyen Ngoc Tram [1 ]
Trinh Duc Nam [2 ]
Truong Xuan Thanh [3 ]
Tran Quang Do [4 ]
Dinh Hong Thai [5 ]
Vu Duy Hai [1 ]
机构
[1] Hanoi Univ Sci & Technol, Sch Elect Telecommun, Hanoi, Vietnam
[2] BME HUST, Minist Hlth, Dept Med Equipment & Contruct, Hanoi, Vietnam
[3] BME HUST, Friendship Hosp, Informat Technol Dept, Hanoi, Vietnam
[4] BME HUST, Bach Mai Hosp, Dept Med Equipment & Consumables, Hanoi, Vietnam
[5] BME HUST, Viet Duc Univ Hosp, Dept Med Equipment & Consumables, Hanoi, Vietnam
关键词
Bioelectrical impedance; phase-angle; nutritional assessment; voltage to current converter; comparator; phase lock loop; phase-difference detector; BODY-COMPOSITION; NUTRITIONAL-STATUS; CANCER; MALNUTRITION; MASS;
D O I
10.1109/ACOMP53746.2021.00030
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The bioelectric impedance phase difference (BIPA) is a characteristic quantity for the changes in the electrical properties of the tissue, obtained from the Bioelectrical Impedance Analysis (BIA). Nowadays, the need for an automatic, specialized and safe device to measure BIPA in medical facilities is very pressing. One method that has been proposed to measure this parameter is to use a multiplier and calculate the value of the phase difference between the two signals. The bias (mean) (+/- SD) of the measurement of the phase difference between two signals with programmed phases using this method was 0.5 +/- 0.2. Consequently, to improve the accuracy of the measurement results, this study was conducted to propose another signal processing method which is based on the comparator and the operating principle of the phase lock loop for the BIPA measurement system. This system still consists of an analog signal generator at 100kHz, a current source circuit. However, the signal processors which process signal received from the body consist of an analog-to-pulse converter and a phase-difference detector. The phase angle between the two signals is then calculated from the DC voltage obtained at the output of the phase-difference detector and compared with the programmed one. The phase difference between the two programmed signals ranges from 5 degrees to 8 degrees with an increment of 0.5 degrees. The obtained results show that the bias of the measurement performed by the system using the proposed method is -0.01, the precision was 0.07 and percentage error was 4.31%.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 50 条
  • [41] Bioelectrical impedance: A new method for measuring post-traumatic swelling
    King, Richard J.
    Clamp, Jonathan A.
    Hutchinson, James W.
    Moran, Christopher G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (07) : 462 - 468
  • [42] Control of the Synchronizing Arrangements on Three-phase Generators with a Phase-angle Measuring Instrument.
    Halder, Wernfried
    Mittelberger, Christof
    Elektrizitatswirtschaft, 1982, 81 (05): : 172 - 174
  • [43] Bioelectrical impedance (BIA)-derived phase angle in adults with obesity: A systematic review
    Di Vincenzo, Olivia
    Marra, Maurizio
    Sacco, Anna Maria
    Pasanisi, Fabrizio
    Scal, Luca
    CLINICAL NUTRITION, 2021, 40 (09) : 5238 - 5248
  • [44] Bioelectrical impedance vector analysis and phase angle in boys with Duchenne muscular dystrophy
    Vermeulen, Karina M.
    Lopes, Marcia M. G. D.
    Grilo, Evellyn C.
    Alves, Camila X.
    Machado, Richele J. A.
    Lais, Lucia L.
    Brandao-Neto, Jose
    Vale, Sancha H. L.
    FOOD & NUTRITION RESEARCH, 2019, 63
  • [45] Bioelectrical impedance phase angle as a nutritional indicator in advanced breast cancer.
    Gupta, D
    Lammersfeld, CA
    Vashi, PG
    Dahk, SL
    Burrows, JL
    Lambert, G
    Grutsch, JF
    Lis, CG
    JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (16) : 91S - 91S
  • [46] Bioelectrical Impedance Phase Angle Changes During Hydration and Prognosis in Advanced Cancer
    Davis, Mellar P.
    Yavuzsen, Tugba
    Khoshknabi, Dilara
    Kirkova, Jordanka
    Walsh, Declan
    Lasheen, Wael
    Lagman, Ruth
    Karafa, Matthew T.
    AMERICAN JOURNAL OF HOSPICE & PALLIATIVE MEDICINE, 2009, 26 (03): : 180 - 187
  • [47] Distribution of Bioelectrical Impedance Vector Analysis and Phase Angle in Korean Elderly and Sarcopenia
    Jiang, Fang-Lin
    Tang, Saizhao
    Eom, Seon-Ho
    Lee, Jae-Young
    Chae, Ji Heon
    Kim, Chul-Hyun
    SENSORS, 2023, 23 (16)
  • [48] The Effect of Passive Dehydration on Phase Angle and Body Composition: A Bioelectrical Impedance Analysis
    Aburto-Corona, Jorge A.
    Calleja-Nunez, Juan J.
    Moncada-Jimenez, Jose
    de Paz, Jose Antonio
    NUTRIENTS, 2024, 16 (14)
  • [49] Malnutrition Assessment in Hemodialysis Patients: Role of Bioelectrical Impedance Analysis Phase Angle
    Rimsevicius, Laurynas
    Gincaite, Alvita
    Vicka, Vaidas
    Sukackiene, Diana
    Pavinic, Jelena
    Miglinas, Marius
    JOURNAL OF RENAL NUTRITION, 2016, 26 (06) : 391 - 395
  • [50] Phase angle and bioelectrical impedance vector analysis in the evaluation of body composition in athletes
    Marini, Elisabetta
    Campa, Francesco
    Buffa, Roberto
    Stagi, Silvia
    Matias, Catarina N.
    Toselli, Stefania
    Sardinha, Luis B.
    Silva, Analiza M.
    CLINICAL NUTRITION, 2020, 39 (02) : 447 - 454