A Method to Improve the Accuracy of the Bioelectrical Impedance Phase-Angle Measuring System

被引:0
|
作者
Nguyen Ngoc Tram [1 ]
Trinh Duc Nam [2 ]
Truong Xuan Thanh [3 ]
Tran Quang Do [4 ]
Dinh Hong Thai [5 ]
Vu Duy Hai [1 ]
机构
[1] Hanoi Univ Sci & Technol, Sch Elect Telecommun, Hanoi, Vietnam
[2] BME HUST, Minist Hlth, Dept Med Equipment & Contruct, Hanoi, Vietnam
[3] BME HUST, Friendship Hosp, Informat Technol Dept, Hanoi, Vietnam
[4] BME HUST, Bach Mai Hosp, Dept Med Equipment & Consumables, Hanoi, Vietnam
[5] BME HUST, Viet Duc Univ Hosp, Dept Med Equipment & Consumables, Hanoi, Vietnam
关键词
Bioelectrical impedance; phase-angle; nutritional assessment; voltage to current converter; comparator; phase lock loop; phase-difference detector; BODY-COMPOSITION; NUTRITIONAL-STATUS; CANCER; MALNUTRITION; MASS;
D O I
10.1109/ACOMP53746.2021.00030
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The bioelectric impedance phase difference (BIPA) is a characteristic quantity for the changes in the electrical properties of the tissue, obtained from the Bioelectrical Impedance Analysis (BIA). Nowadays, the need for an automatic, specialized and safe device to measure BIPA in medical facilities is very pressing. One method that has been proposed to measure this parameter is to use a multiplier and calculate the value of the phase difference between the two signals. The bias (mean) (+/- SD) of the measurement of the phase difference between two signals with programmed phases using this method was 0.5 +/- 0.2. Consequently, to improve the accuracy of the measurement results, this study was conducted to propose another signal processing method which is based on the comparator and the operating principle of the phase lock loop for the BIPA measurement system. This system still consists of an analog signal generator at 100kHz, a current source circuit. However, the signal processors which process signal received from the body consist of an analog-to-pulse converter and a phase-difference detector. The phase angle between the two signals is then calculated from the DC voltage obtained at the output of the phase-difference detector and compared with the programmed one. The phase difference between the two programmed signals ranges from 5 degrees to 8 degrees with an increment of 0.5 degrees. The obtained results show that the bias of the measurement performed by the system using the proposed method is -0.01, the precision was 0.07 and percentage error was 4.31%.
引用
下载
收藏
页码:169 / 175
页数:7
相关论文
共 50 条
  • [1] A bioelectrical impedance phase angle measuring system for assessment of nutritional status
    Zhang, Guanghao
    Huo, Xiaolin
    Wu, Changzhe
    Zhang, Cheng
    Duan, Zhongping
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 3657 - 3664
  • [2] FAST RESPONSE PHASE-ANGLE MEASURING INSTRUMENT
    RAMAMURTHI, VP
    PERINBAM, JRP
    ELECTRONIC ENGINEERING, 1978, 50 (604): : 29 - 29
  • [3] BIOELECTRIC IMPEDANCE PHASE-ANGLE AND BODY-COMPOSITION
    BAUMGARTNER, RN
    CHUMLEA, WC
    ROCHE, AF
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (01): : 16 - 23
  • [4] THE CONSTANT PHASE-ANGLE IMPEDANCE OF THE FINITE SIERPINSKI ELECTRODE
    CHU, YT
    SOLID STATE IONICS, 1988, 26 (04) : 299 - 302
  • [5] BIOELECTRIC IMPEDANCE PHASE-ANGLE AND BODY-COMPOSITION
    BAUMGARTNER, RN
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1987, 72 (02) : 176 - 176
  • [6] Relationship between cognitive function and phase angle measured with a bioelectrical impedance system
    Yosuke Yamada
    Kazuhisa Watanabe
    Chisato Fujisawa
    Hitoshi Komiya
    Hirotaka Nakashima
    Tomihiko Tajima
    Hiroyuki Umegaki
    European Geriatric Medicine, 2024, 15 : 201 - 208
  • [7] Relationship between cognitive function and phase angle measured with a bioelectrical impedance system
    Yamada, Yosuke
    Watanabe, Kazuhisa
    Fujisawa, Chisato
    Komiya, Hitoshi
    Nakashima, Hirotaka
    Tajima, Tomihiko
    Umegaki, Hiroyuki
    EUROPEAN GERIATRIC MEDICINE, 2024, 15 (01) : 201 - 208
  • [8] Bioelectrical Impedance of Vectorial Analysis and Phase Angle in Adolescents
    Mathias-Genovez, Mariana G.
    Oliveira, Cristiana C.
    Camelo, Jose S., Jr.
    Del Ciampo, Luiz A.
    Monteiro, Jacqueline P.
    JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2016, 35 (03) : 262 - 270
  • [9] Bioelectrical impedance phase angle in sport: a systematic review
    Di Vincenzo, Olivia
    Marra, Maurizio
    Scalfi, Luca
    JOURNAL OF THE INTERNATIONAL SOCIETY OF SPORTS NUTRITION, 2019, 16 (01) : 1
  • [10] BIOELECTRICAL IMPEDANCE PHASE ANGLE AS INTRADIALYTIC HYPOTENSION PREDICTOR
    Vicka, Vaidas
    Rimsevicius, Laurynas
    Gincaite, Alvita
    Sukackiene, Diana
    Miglinas, Marius
    JOURNAL OF HYPERTENSION, 2016, 34 : E231 - E231