Application of the heat pipe to enhance the performance of the vapor compression refrigeration system

被引:23
|
作者
Nakkaew, Santiphap [1 ,2 ]
Chitipalungsri, Thunyawat [2 ]
Ahn, Ho Seon [3 ]
Jerng, Dong-Wook [4 ]
Asirvatham, Lazarus Godson [5 ]
Dalkilic, Ahmet Selim [6 ]
Mahian, Omid [7 ]
Wongwises, Somchai [1 ,8 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Fluid Mech Thermal Engn & Multiphase Flow Res Lab, Dept Mech Engn, Fac Engn, Bangkok, Thailand
[2] Saijo Denki Int Co Ltd, Nonthaburi 11000, Thailand
[3] Incheon Natl Univ, Dept Mech Engn, Incheon, South Korea
[4] Chung Ang Univ, Sch Energy Syst Engn, Seoul, South Korea
[5] Karunya Inst Technol & Sci, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[6] Yildiz Tech Univ, Heat & Thermodynam Div, Dept Mech Engn, Fac Mech Engn, Istanbul, Turkey
[7] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xian, Shaanxi, Peoples R China
[8] Royal Soc Thailand, Acad Sci, Bangkok 10300, Thailand
关键词
Air conditioner; Energy efficiency ratio; Heat pipe; Vapor compression refrigeration system; AIR-CONDITIONING SYSTEM; EXCHANGER; ENERGY; RECOVERY; CONFIGURATIONS; SAVINGS;
D O I
10.1016/j.csite.2019.100531
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an application of the heat pipe to enhance the performance of the air conditioner. The study is done in two steps. First, the effect of pertinent parameters on the heat transfer rate of the heat pipe set is investigated. Then the heat pipe set is installed in the split-type air conditioner and tested in the actual condition. The heat pipe set consists of a heat pipe, holder, and plate fins. The length of the heat pipe is 300 mm. The working fluid inside the heat pipe is deionized water. Two different geometries of holder which are A-geometry and B-geometry are used in the study. Both holders are made of copper. The numbers of heat pipe in each set are 2, 4 and 6. The experimental results show that the maximum heat transfer rate obtained from the heat pipe set is about 240 W at the air velocity of 5 m/s and the heater surface temperature of 70 degrees C. The heat pipe set with A-geometry consisting of 6 heat pipes is the best configuration. However, this configuration provides the highest air-side pressure drop because of the highest velocity. The best heat pipe set is installed at the outlet of the compressor in the air conditioner with a cooling capacity of 9,000 BTU/hr. The experimental results show that the energy efficiency ratios (EER) of the air conditioners with heat pipe set are slightly higher than those of the conventional air conditioner. The EER of air conditioners with copper holder of heat pipe increases about 3.11%. The results from the present study are important for enhancing the performance of the vapor compression refrigeration system.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] SPECIFIC CONSUMPTION ANALYSIS OF VAPOR COMPRESSION REFRIGERATION SYSTEM
    Bai Xueliang
    Zhou Shaoxiang
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017 VOL 6, 2018,
  • [42] MINIATURE VAPOR COMPRESSION REFRIGERATION SYSTEM FOR ELECTRONICS COOLING
    Wu, Zhihui
    Du, R.
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 282 - 286
  • [43] Performance enhancement and environmental analysis of vapor compression refrigeration system with dedicated mechanical subcooling
    Naveen Solanki
    Akhilesh Arora
    Raj Kumar Singh
    International Journal of Air-Conditioning and Refrigeration, 31
  • [44] Performance investigation of vapor and liquid injection on a refrigeration system operating at high compression ratio
    Lee, Daehui
    Seong, Kyoung Jin
    Lee, Jinho
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 53 : 115 - 125
  • [45] Performance enhancement and environmental analysis of vapor compression refrigeration system with dedicated mechanical subcooling
    Solanki, Naveen
    Arora, Akhilesh
    Singh, Raj Kumar
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2023, 31 (01)
  • [46] Improved performance of a nanorefrigerant-based vapor compression refrigeration system: A new alternative
    Kundan, Lal
    Sing, Kuljeet
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (01) : 106 - 123
  • [47] Optimization of Performance of Vapor Compression Refrigeration System (VCRS) by Controlling The Motor Fan of The Evaporator
    Hanafi, Hamad Said
    Amin, Zulkifli
    Iskandar, R.
    DISRUPTIVE INNOVATION IN MECHANICAL ENGINEERING FOR INDUSTRY COMPETITIVENESS, 2018, 1983
  • [48] Performance assessment of photovoltaic/thermal hybrid adsorption-vapor compression refrigeration system
    Gado M.G.
    Ookawara S.
    Nada S.
    Hassan H.
    Journal of Energy Systems, 2022, 6 (02): : 209 - 220
  • [49] Experimental Investigation of Performance Enhancement of a Vapor Compression Refrigeration System by Vortex Tube Cooling
    Puangcharoenchai, Phupoom
    Kachapongkun, Pongsakorn
    Rattanadecho, Phadungsak
    Prommas, Ratthasak
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2020, 28 (02)
  • [50] Modeling and effects of air temperature and humidity on vapor compression refrigeration system energy performance
    Xie, Bingyi
    Wang, Xinli
    Wang, Lei
    Yin, Xiaohong
    Liu, Hongbo
    Jia, Lei
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 2030 - 2035