Application of the heat pipe to enhance the performance of the vapor compression refrigeration system

被引:23
|
作者
Nakkaew, Santiphap [1 ,2 ]
Chitipalungsri, Thunyawat [2 ]
Ahn, Ho Seon [3 ]
Jerng, Dong-Wook [4 ]
Asirvatham, Lazarus Godson [5 ]
Dalkilic, Ahmet Selim [6 ]
Mahian, Omid [7 ]
Wongwises, Somchai [1 ,8 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Fluid Mech Thermal Engn & Multiphase Flow Res Lab, Dept Mech Engn, Fac Engn, Bangkok, Thailand
[2] Saijo Denki Int Co Ltd, Nonthaburi 11000, Thailand
[3] Incheon Natl Univ, Dept Mech Engn, Incheon, South Korea
[4] Chung Ang Univ, Sch Energy Syst Engn, Seoul, South Korea
[5] Karunya Inst Technol & Sci, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[6] Yildiz Tech Univ, Heat & Thermodynam Div, Dept Mech Engn, Fac Mech Engn, Istanbul, Turkey
[7] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xian, Shaanxi, Peoples R China
[8] Royal Soc Thailand, Acad Sci, Bangkok 10300, Thailand
关键词
Air conditioner; Energy efficiency ratio; Heat pipe; Vapor compression refrigeration system; AIR-CONDITIONING SYSTEM; EXCHANGER; ENERGY; RECOVERY; CONFIGURATIONS; SAVINGS;
D O I
10.1016/j.csite.2019.100531
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an application of the heat pipe to enhance the performance of the air conditioner. The study is done in two steps. First, the effect of pertinent parameters on the heat transfer rate of the heat pipe set is investigated. Then the heat pipe set is installed in the split-type air conditioner and tested in the actual condition. The heat pipe set consists of a heat pipe, holder, and plate fins. The length of the heat pipe is 300 mm. The working fluid inside the heat pipe is deionized water. Two different geometries of holder which are A-geometry and B-geometry are used in the study. Both holders are made of copper. The numbers of heat pipe in each set are 2, 4 and 6. The experimental results show that the maximum heat transfer rate obtained from the heat pipe set is about 240 W at the air velocity of 5 m/s and the heater surface temperature of 70 degrees C. The heat pipe set with A-geometry consisting of 6 heat pipes is the best configuration. However, this configuration provides the highest air-side pressure drop because of the highest velocity. The best heat pipe set is installed at the outlet of the compressor in the air conditioner with a cooling capacity of 9,000 BTU/hr. The experimental results show that the energy efficiency ratios (EER) of the air conditioners with heat pipe set are slightly higher than those of the conventional air conditioner. The EER of air conditioners with copper holder of heat pipe increases about 3.11%. The results from the present study are important for enhancing the performance of the vapor compression refrigeration system.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] An overview of vapor compression refrigeration system performance enhancement mechanism by utilizing nanolubricants
    Nugroho, Agus
    Mamat, Rizalman
    Bo, Zhang
    Azmi, W. H.
    Alenezi, Raslan
    Najafi, Gholamhassan
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (17) : 9139 - 9161
  • [22] Thermoeconomic model for diagnostic techniques to evaluated vapor compression refrigeration system performance
    Mendes, Tiago
    Orozco, Dimas Jose Rua
    Guzella, Matheus dos Santos
    Oliveira, Jose Ricardo Ferreira -
    Venturini, Osvaldo Jose
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 167 : 166 - 176
  • [23] Performance optimization of thermoelectric and vapor compression hybrid refrigeration system by allocating power
    Zhang, Jing-yang
    Xu, Sheng
    Mou, Xin-zhu
    Meng, Ling-qi
    Li, Ye-xiang
    Cheng, Feng-na
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [24] Analytical study on condensation heat distribution modes in a hybrid vapor compression refrigeration system
    She, Xiaohui
    Yin, Yonggao
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2015, 88 : 288 - 302
  • [25] Experimental investigation and application potential analysis of vapor compression refrigeration integrated mechanically-driven loop heat pipe for data centers cooling
    Liu, Shuailing
    Ma, Guoyuan
    Li, Xiang
    Xu, Shuxue
    APPLIED THERMAL ENGINEERING, 2025, 259
  • [26] Thermodynamic evaluation of heat recovery through a Canopus heat exchanger for vapor compression refrigeration (VCR) system
    Kaushik, S. C.
    Panwar, N. L.
    Reddy, V. Siva
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2012, 110 (03) : 1493 - 1499
  • [27] DESIGN OF A SCREW HEAT EXCHANGER AS THE LIQUID-SUCTION HEAT EXCHANGER IN A VAPOR COMPRESSION REFRIGERATION SYSTEM
    Antonio, Francis J.
    Berana, Menandro S.
    Danao, Louis Angelo M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 8B, 2016,
  • [28] Thermodynamic evaluation of heat recovery through a Canopus heat exchanger for vapor compression refrigeration (VCR) system
    S. C. Kaushik
    N. L. Panwar
    V. Siva Reddy
    Journal of Thermal Analysis and Calorimetry, 2012, 110 : 1493 - 1499
  • [29] Numerical simulation of the effects of a suction line heat exchanger on vapor compression refrigeration cycle performance
    Jeong, Ji Hwan
    Park, Sang-Goo
    Sarker, Debasish
    Chang, Keun Sun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (04) : 1213 - 1226
  • [30] Numerical simulation of the effects of a suction line heat exchanger on vapor compression refrigeration cycle performance
    Ji Hwan Jeong
    Sang-Goo Park
    Debasish Sarker
    Keun Sun Chang
    Journal of Mechanical Science and Technology, 2012, 26 : 1213 - 1226