Application of the heat pipe to enhance the performance of the vapor compression refrigeration system

被引:23
|
作者
Nakkaew, Santiphap [1 ,2 ]
Chitipalungsri, Thunyawat [2 ]
Ahn, Ho Seon [3 ]
Jerng, Dong-Wook [4 ]
Asirvatham, Lazarus Godson [5 ]
Dalkilic, Ahmet Selim [6 ]
Mahian, Omid [7 ]
Wongwises, Somchai [1 ,8 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Fluid Mech Thermal Engn & Multiphase Flow Res Lab, Dept Mech Engn, Fac Engn, Bangkok, Thailand
[2] Saijo Denki Int Co Ltd, Nonthaburi 11000, Thailand
[3] Incheon Natl Univ, Dept Mech Engn, Incheon, South Korea
[4] Chung Ang Univ, Sch Energy Syst Engn, Seoul, South Korea
[5] Karunya Inst Technol & Sci, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[6] Yildiz Tech Univ, Heat & Thermodynam Div, Dept Mech Engn, Fac Mech Engn, Istanbul, Turkey
[7] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xian, Shaanxi, Peoples R China
[8] Royal Soc Thailand, Acad Sci, Bangkok 10300, Thailand
关键词
Air conditioner; Energy efficiency ratio; Heat pipe; Vapor compression refrigeration system; AIR-CONDITIONING SYSTEM; EXCHANGER; ENERGY; RECOVERY; CONFIGURATIONS; SAVINGS;
D O I
10.1016/j.csite.2019.100531
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an application of the heat pipe to enhance the performance of the air conditioner. The study is done in two steps. First, the effect of pertinent parameters on the heat transfer rate of the heat pipe set is investigated. Then the heat pipe set is installed in the split-type air conditioner and tested in the actual condition. The heat pipe set consists of a heat pipe, holder, and plate fins. The length of the heat pipe is 300 mm. The working fluid inside the heat pipe is deionized water. Two different geometries of holder which are A-geometry and B-geometry are used in the study. Both holders are made of copper. The numbers of heat pipe in each set are 2, 4 and 6. The experimental results show that the maximum heat transfer rate obtained from the heat pipe set is about 240 W at the air velocity of 5 m/s and the heater surface temperature of 70 degrees C. The heat pipe set with A-geometry consisting of 6 heat pipes is the best configuration. However, this configuration provides the highest air-side pressure drop because of the highest velocity. The best heat pipe set is installed at the outlet of the compressor in the air conditioner with a cooling capacity of 9,000 BTU/hr. The experimental results show that the energy efficiency ratios (EER) of the air conditioners with heat pipe set are slightly higher than those of the conventional air conditioner. The EER of air conditioners with copper holder of heat pipe increases about 3.11%. The results from the present study are important for enhancing the performance of the vapor compression refrigeration system.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Experimental analysis of a vapor compression refrigeration cycle with heat pipe
    Yilmaz, Metin
    Cimsit, Canan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024,
  • [2] THEORETICAL STUDIES ON THE APPLICATION OF PULSATING HEAT PIPE IN VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Naik, Rudra
    Pinto, Linford
    Narasimha, K. Rama
    Pundarika, G.
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 1801 - +
  • [3] Mini-channel evaporator/heat pipe assembly for a chip cooling vapor compression refrigeration system
    Ribeiro, Guilherme B.
    Barbosa, Jader R., Jr.
    Prata, Alvaro T.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (07): : 1402 - 1412
  • [4] Experimental Investigation of the Closed Loop Oscillating Heat Pipe Condenser for Vapor Compression Refrigeration
    Yeunyongkul, P.
    Sakulchangsatjatai, P.
    Kammuang-Lue, N.
    Terdtoon, P.
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2012, 15 (02): : 117 - 122
  • [5] Experimental investigation of dehumidification performance of a vapor compression refrigeration system
    Tang, Chunli
    Vafai, Kambiz
    Gu, Conghui
    Gloria, Kasolongo Ndongo
    Karim, M. D. Razaul
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 137
  • [6] Investigation Analysis on the performance improvement of a vapor compression refrigeration system
    Chandra, M. Ravi
    Reddy, K. Manikanth
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 1638 - +
  • [7] THE PERFORMANCE OF PROPANE ISOBUTANE MIXTURES IN A VAPOR-COMPRESSION REFRIGERATION SYSTEM
    RICHARDSON, RN
    BUTTERWORTH, JS
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (01): : 58 - 62
  • [8] Performance Analysis of Ejector Assisted Vapor Compression Cascade Refrigeration System
    Beltran-Lopez, Marte E.
    Colorado-Garrido, Dario
    Herrera-Romero, Jose, V
    Escobedo-Trujillo, Beatris A.
    Alaffita-Hernandez, Francisco A.
    ADVANCES IN COMPUTATIONAL HEAT AND MASS TRANSFER, ICCHMT 2023, VOL 2, 2024, : 439 - 455
  • [9] Performance degradation of a vapor compression refrigeration system under fouled conditions
    Qureshi, Bilal Ahmed
    Zubair, Syed M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (04): : 1016 - 1027
  • [10] The effect of nanorefrigerants on performance of the vapor compression refrigeration system: a comprehensive review
    Bilen, Kemal
    Dagidir, Kayhan
    Arcaklioglu, Erol
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (02) : 3177 - 3203