Patient Outcomes Following Implantation of Modular Neck Hip Prostheses in Primary Total Hip Arthroplasty

被引:2
|
作者
Borden, Robert [1 ]
Pour, Aidin Eslam [1 ]
Murayama, Takayuki [1 ]
Blaha, J. David [1 ]
机构
[1] Univ Michigan, 1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
关键词
adverse tissue response to metal debris; corrosion; modular neck femoral stem; pseudotumor; total hip arthroplasty; SYSTEM;
D O I
10.1520/STP159120140151
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bimodular femoral neck components were introduced to optimize implant size and offset. Failures have been reported and long-term outcome of modular necks must be assessed. The purpose of this study was to investigate the results of a series of modular neck implants and catalog the causes of failure of them. Our series included 277 hips (244 patients) with Profemur-E and Profemur-Z femoral stems (Wright Medical Technology Inc., now MicroPort Orthopaedics Arlington, TN). Data for this cohort of patients included demographics, implant dimensions, and the type of articular surface. Correlation of these variables with failure was analyzed to estimate the effect of each on survivorship. Implant failure was defined as cases requiring revision surgery. Seven cases were revised for implant neck fracture (2.5 %), and four were revised for adverse local tissue reactions (ALTR; 1.4 %). Seven required replacement of fractured neck with a cobalt-chromium (CoCr) modular neck. Regression analysis showed that a 1-unit increase in body mass index (BMI) increased the probability of neck fracture by a factor of 1.19 and every 4-mm increase in head diameter increased the chance of neck fracture by a factor of 3.2. Increase in neck offset is associated with a 1.83 times increased likelihood of neck fracture. Co levels correlated positively with neck fracture, and titanium levels correlated positively with gas in the joint. Cr and titanium levels were significantly higher in patients who had aseptic revision surgery. These data suggest that failure of modular neck junctions may be potentiated by higher BMI, greater offset, and larger head diameters. It is suspected that these factors contribute to modular neck failure by creating a stronger moment arm about the neck's insertion into the stem. A lower level of titanium than 7 ng/dL might be considered as the threshold. These data may help identify a set of factors that contraindicate the use of modular neck junctions.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [1] Outcomes of primary total hip arthroplasty following septic arthritis of the hip
    Bettencourt, J. W.
    Wyles, C. C.
    Osmon, D. R.
    Hanssen, A. D.
    Berry, D. J.
    Abdel, M. P.
    BONE & JOINT JOURNAL, 2022, 104B (02): : 227 - 234
  • [2] Do Patient Outcomes Vary by Patient Age Following Primary Total Hip Arthroplasty?
    Ayers, David C.
    Yousef, Mohamed
    Zheng, Hua
    Yang, Wenyun
    Franklin, Patricia D.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S510 - S516
  • [3] Correlation of Corrosion and Biomechanics in the Retrieval of a Single Modular Neck Total Hip Arthroplasty Design Modular Neck Total Hip Arthroplasty System
    Lanting, Brent A.
    Teeter, Matthew G.
    Vasarhelyi, Edward M.
    Ivanov, Todor G.
    Howard, James L.
    Naudie, Douglas D. R.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (01): : 135 - 140
  • [4] Primary total hip arthroplasty with modular stems
    Keggi, Kristaps J.
    Kennon, Robert E.
    Keggi, John M.
    CURRENT ORTHOPAEDIC PRACTICE, 2008, 19 (02): : 124 - 126
  • [5] Medium-term Outcomes of Cemented Prostheses and Cementless Modular Prostheses in Revision Total Hip Arthroplasty
    Long Wang
    Pengfei Lei
    Jie Xie
    Kanghua Li
    Zixun Dai
    Yihe Hu
    Scientific Reports, 3
  • [6] Medium-term Outcomes of Cemented Prostheses and Cementless Modular Prostheses in Revision Total Hip Arthroplasty
    Wang, Long
    Lei, Pengfei
    Xie, Jie
    Li, Kanghua
    Dai, Zixun
    Hu, Yihe
    SCIENTIFIC REPORTS, 2013, 3
  • [7] Modular neck total hip arthroplasty - a perfect storm
    Humadi, Ali
    Jamieson, Richard
    Chao, Tat
    Tacey, Mark
    Khoury, Elie
    HIP INTERNATIONAL, 2016, 26 (02) : 128 - 131
  • [8] Impact of Preoperative Opioid Use on Patient Outcomes Following Primary Total Hip Arthroplasty
    Singh, Vivek
    Kugelman, David N.
    Rozell, Joshua C.
    Meftah, Morteza
    Schwarzkopf, Ran
    Davidovitch, Roy, I
    ORTHOPEDICS, 2021, 44 (02) : 77 - 84
  • [9] Cementless modular neck stems: are they a safe option in primary total hip arthroplasty?
    Pelayo-de-Tomás J.M.
    Rodrigo-Pérez J.L.
    Novoa-Parra C.D.
    Lizaur-Utrilla A.
    Morales-Suárez-Varela M.
    Blas-Dobón J.A.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (3) : 463 - 469
  • [10] Effect of a modular neck hip prosthesis on anteversion and hip rotation in total hip arthroplasty for developmental dysplasia of the hip
    Nakahara, Ema
    Uemura, Keisuke
    Ando, Wataru
    Hamada, Hidetoshi
    Takao, Masaki
    Sugano, Nobuhiko
    JOURNAL OF ARTIFICIAL ORGANS, 2020, 23 (03) : 255 - 261