A novel on-line method and equipment to detect local problems in turbine generators

被引:0
|
作者
Sorita, T [1 ]
Enmanji, K [1 ]
Kato, K [1 ]
Takashima, M [1 ]
Nakamura, K [1 ]
机构
[1] Mitsubishi Elect Corp, Adv Technol R&D Ctr, Amagasaki, Hyogo 6618661, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A continuous mass-spectrometric analysis of the evolved gases has been studied to achieve a novel on-line monitor for local overheating in hydrogen cooled turbine generators. The organic species evolved from the materials and the seal oil used in the generators were successfully detected employing a quadrupole mass-spectrometer. The overheating of the material and the oil contamination in the detector can be clearly discriminated by selecting mass numbers (channels) to detect out of 50 to 250 amu. More, each gas evolved from the material yields its individual mass spectrum, and hence the mass-spectrometric detection can define the material in which overheating spot exists by reference to the library of the decomposition gases. The mass-spectrometric equipment win realize a practical on-line (or continuous) monitor to detect local overheating in the operating turbine generators, combined with numerical data recognition system and the kinetic interpretation of the gas-evolution.
引用
下载
收藏
页码:552 / 555
页数:4
相关论文
共 50 条
  • [41] Novel method of on-line monitoring vacuum for vacuum circuit breaker
    Zhenjiang Tailifeng Electronic Co. Ltd., Zhenjiang 212021, China
    Dianli Xitong Zidonghue, 2006, 11 (49-51+60):
  • [42] Novel Features and PRPD Image Denoising Method for Improved Single-Source Partial Discharges Classification in On-Line Hydro-Generators
    Araujo, Ramon C. F.
    de Oliveira, Rodrigo M. S.
    Brasil, Fernando S.
    Barros, Fabricio J. B.
    ENERGIES, 2021, 14 (11)
  • [43] A New Method for On-Line Monitoring of Pressure-Retaining Equipment in Nuclear Power Plants
    Jia, J. H.
    Zhang, C.
    Zhang, Z. Q.
    Xuan, F. Z.
    Zhou, S. P.
    Tu, S. -T.
    PRESSURE VESSEL TECHNOLOGY: PREPARING FOR THE FUTURE, 2015, 130 : 1592 - 1597
  • [44] Extraction of symptom for on-line diagnosis of power equipment based on method of time series analysis
    Yang, L
    Yang, MZ
    Yan, Z
    Shi, BZ
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 314 - 317
  • [45] Study on measurement error test method of on-line insulation monitoring device for capacitive equipment
    Yang, Yuan
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 844 - 847
  • [46] New noise rejection techniques on pulse-by-pulse basis for on-line partial discharge measurement of turbine generators - Response
    Itoh, K
    Kaneda, Y
    Kitamura, S
    Kimura, K
    Nishimura, A
    Tanaka, T
    Tokura, H
    Okada, I
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (03) : 593 - 594
  • [47] Study on trend analysis method for on-line insulation diagnosing of capacitive-type equipment
    Huang, XH
    Yan, Z
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 755 - 758
  • [48] A New Proposed Method for Interpretation On-line Partial Discharge Measurements Data of Turbine Generator
    Baboraik, A. M.
    Usachev, A. E.
    Ali, Ziad M.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (03) : 1301 - 1311
  • [49] A New On-Line Method of Measuring Air Leakage Rate of Steam Turbine Vacuum System
    Guo Ying
    Wang Xuetong
    Zhou Guangshun
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [50] A New Proposed Method for Interpretation On-line Partial Discharge Measurements Data of Turbine Generator
    A. M. Baboraik
    A. E. Usachev
    Ziad M. Ali
    Journal of Electrical Engineering & Technology, 2020, 15 : 1301 - 1311