Diagnostic accuracy of multidetector-row computed tomography for hilar cholangiocarcinoma

被引:25
|
作者
Akamatsu, Nobuhisa [2 ]
Sugawara, Yasuhiko [1 ]
Osada, Hisato [3 ]
Okada, Takenori [3 ]
Itoyama, Shinji [4 ]
Komagome, Masahiko [2 ]
Shin, Nobuhiro [2 ]
Cho, Narihiro [2 ]
Ishida, Takashi [2 ]
Ozawa, Fumiaki [2 ]
Hashimoto, Daijo [2 ]
机构
[1] Univ Tokyo, Dept Surg, Grad Sch Med, Artificial Organ & Transplantat Div,Bunkyo Ku, Tokyo 1138655, Japan
[2] Saitama Med Univ, Dept Hepatobiliary Pancreat Surg, Saitama, Japan
[3] Saitama Med Univ, Dept Radiol, Saitama, Japan
[4] Saitama Med Univ, Dept Pathol, Saitama, Japan
关键词
cholangiocarcinoma; invasion; lymph node metastasis; multidetector computed tomography; sensitivity; BILE-DUCT CARCINOMA; PREOPERATIVE EVALUATION; DIRECT CHOLANGIOGRAPHY; HELICAL CT; RESECTION; RESECTABILITY; CANCER; SONOGRAPHY; MDCT; OBSTRUCTION;
D O I
10.1111/j.1440-1746.2009.06113.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: The aim of this study was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for the evaluation of tumor spread in hilar cholangiocarcinoma. Methods: Images obtained from a 16-detector row scanner of 22 patients were interpreted. The diagnostic accuracy of longitudinal ductal spread, vertical invasion (including hepatic parenchyma), and lymph node metastasis was assessed with reference to histopathological findings. Results: The location of the tumor was correctly diagnosed in 95% of cases (21/22), but in five of these cases, the cut end of the intrahepatic bile duct was positive, resulting in 77% diagnostic accuracy for longitudinal spread. Among the patients with a negative bile duct surgical margin, there was a significant difference in the measurement of tumor spread between MDCT and microscopic investigation (P < 0.001). For vertical invasion, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT were 69%, 100%, 100%, and 69% for the liver parenchyma, respectively. The sensitivity, specificity, PPV, and NPV of MDCT for lymph node metastasis were 50%, 75%, 43%, and 80%, respectively. Conclusions: The diagnostic accuracy of MDCT for tumor location and vertical invasion was satisfactory, but ductal spread was underestimated in comparison with microscopic measurements.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [41] Multidetector-row computed tomography in the planning of abdominal perforator flaps
    Masia, J.
    Clavero, J. A.
    Larranaga, J. R.
    Alomar, X.
    Pons, G.
    Serret, P.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2006, 59 (06): : 594 - 599
  • [42] Multiple Atrial Septal Defects in Multidetector-Row Computed Tomography
    Tada, Norio
    Takizawa, Kaname
    Mizutani, Yukiko
    Suzuki, Shinichi
    Sakurai, Mie
    Arai, Takeshi
    Inoue, Naoto
    Meguro, Taiichiro
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : E61 - E62
  • [43] Evaluation of Biliary Malignancies Using Multidetector-Row Computed Tomography
    Kim, Myeong-Jin
    Choi, Jin-Young
    Chung, Yong Eun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (04) : 496 - 505
  • [44] Impact of Biliary Drainage on Multidetector-Row Computed Tomography on R0 Resection of Perihilar Cholangiocarcinoma
    Hosokawa, Isamu
    Shimizu, Hiroaki
    Yoshitomi, Hideyuki
    Furukawa, Katsunori
    Takayashiki, Tsukasa
    Miyazaki, Masaru
    Ohtsuka, Masayuki
    WORLD JOURNAL OF SURGERY, 2018, 42 (11) : 3676 - 3684
  • [45] Cardiac multidetector-row computed tomography in patients with unstable angina
    Dirksen, MS
    Jukema, JW
    Bax, JJ
    Lamb, HJ
    Boersma, E
    Tuinenburg, JC
    Geleijns, J
    van der Wall, EE
    de Roos, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (04): : 457 - 461
  • [46] Occlusion of coronary aneurysms demonstrated by multidetector-row computed tomography
    Sei Komatsu
    Stephan Achenbach
    Dieter Ropers
    Werner G. Daniel
    Yasunori Ueda
    Tobias Pflederer
    Alexander Kuhlmann
    Martin Wechsel
    Atsushi Hirayama
    Kazuhisa Kodama
    Clinical Research in Cardiology, 2007, 96 : 575 - 578
  • [47] Multidetector-row computed tomography in suspected pulmonary embolism - Reply
    Perrier, A
    Roy, PM
    Meyer, G
    NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (06): : 630 - 631
  • [48] Clinical significance of multidetector-row computed tomography in breast surgery
    Doihara, Hiroyoshi
    Fujita, Takeo
    Takabatake, Daisuke
    Takahashi, Hirotoshi
    Ogasawara, Yutaka
    Shimizu, Nobuyoshi
    BREAST JOURNAL, 2006, 12 (05): : S204 - S209
  • [49] Multidetector-row computed tomography management of acute pulmonary embolism
    Yasui, Takahiro
    Tanabe, Nobuhiro
    Terada, Jiro
    Yanagawa, Noriyuki
    Shimizu, Hidefumi
    Matsubara, Hiroshi
    Hoshino, Susumu
    Fujikawa, Ayako
    Mizuno, Satoko
    Yatomi, Mari
    Sakao, Seiichiro
    Uruma, Takahiro
    Kasahara, Yasunori
    Takiguchi, Yuichi
    Tatsumi, Koichiro
    Kuriyama, Takayuki
    CIRCULATION JOURNAL, 2007, 71 (12) : 1948 - 1954
  • [50] Application of Multidetector-Row Computed Tomography in Propeller Flap Planning
    Ono, Shimpei
    Chung, Kevin C.
    Hayashi, Hiromitsu
    Ogawa, Rei
    Takami, Yoshihiro
    Hyakusoku, Hiko
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 127 (02) : 703 - 711