Diagnostic accuracy of multidetector-row computed tomography for hilar cholangiocarcinoma

被引:25
|
作者
Akamatsu, Nobuhisa [2 ]
Sugawara, Yasuhiko [1 ]
Osada, Hisato [3 ]
Okada, Takenori [3 ]
Itoyama, Shinji [4 ]
Komagome, Masahiko [2 ]
Shin, Nobuhiro [2 ]
Cho, Narihiro [2 ]
Ishida, Takashi [2 ]
Ozawa, Fumiaki [2 ]
Hashimoto, Daijo [2 ]
机构
[1] Univ Tokyo, Dept Surg, Grad Sch Med, Artificial Organ & Transplantat Div,Bunkyo Ku, Tokyo 1138655, Japan
[2] Saitama Med Univ, Dept Hepatobiliary Pancreat Surg, Saitama, Japan
[3] Saitama Med Univ, Dept Radiol, Saitama, Japan
[4] Saitama Med Univ, Dept Pathol, Saitama, Japan
关键词
cholangiocarcinoma; invasion; lymph node metastasis; multidetector computed tomography; sensitivity; BILE-DUCT CARCINOMA; PREOPERATIVE EVALUATION; DIRECT CHOLANGIOGRAPHY; HELICAL CT; RESECTION; RESECTABILITY; CANCER; SONOGRAPHY; MDCT; OBSTRUCTION;
D O I
10.1111/j.1440-1746.2009.06113.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: The aim of this study was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for the evaluation of tumor spread in hilar cholangiocarcinoma. Methods: Images obtained from a 16-detector row scanner of 22 patients were interpreted. The diagnostic accuracy of longitudinal ductal spread, vertical invasion (including hepatic parenchyma), and lymph node metastasis was assessed with reference to histopathological findings. Results: The location of the tumor was correctly diagnosed in 95% of cases (21/22), but in five of these cases, the cut end of the intrahepatic bile duct was positive, resulting in 77% diagnostic accuracy for longitudinal spread. Among the patients with a negative bile duct surgical margin, there was a significant difference in the measurement of tumor spread between MDCT and microscopic investigation (P < 0.001). For vertical invasion, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT were 69%, 100%, 100%, and 69% for the liver parenchyma, respectively. The sensitivity, specificity, PPV, and NPV of MDCT for lymph node metastasis were 50%, 75%, 43%, and 80%, respectively. Conclusions: The diagnostic accuracy of MDCT for tumor location and vertical invasion was satisfactory, but ductal spread was underestimated in comparison with microscopic measurements.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [21] Multidetector-row spiral computed tomography in chest emergencies
    Wildberger, J. E.
    Leiner, T.
    Mahnken, A. H.
    RADIOLOGE, 2009, 49 (06): : 492 - 500
  • [22] Multidetector-row computed tomography imaging of splenic trauma
    Marmery, Helen
    Shanmuganathan, K.
    SEMINARS IN ULTRASOUND CT AND MRI, 2006, 27 (05) : 404 - 419
  • [23] Multidetector-row computed tomography demonstration of Eagle syndrome
    Wani N.A.
    Lone P.
    Shafi T.
    Jehangir M.
    The Egyptian Journal of Otolaryngology, 2015, 31 (4) : 264 - 266
  • [24] Multidetector-row computed tomography in cerebral hydatid cyst
    Wani, Nisar A.
    Kosar, Tasleem L.
    Khan, Abdul Qayum
    Ahmad, Sheikh Shahnawaz
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2010, 1 (02) : 112 - 114
  • [25] Multidetector-row computed tomography in suspected pulmonary embolism
    Perrier, A
    Roy, P
    Sanchez, O
    Le Gal, G
    Meyer, G
    Gourdier, A
    Furber, A
    Revel, M
    Howarth, N
    Davido, A
    Bounameaux, H
    NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (17): : 1760 - 1768
  • [26] The diagnostic accuracy of lymph node metastasis for multidetector-row computed tomography (MDCT) in the preoperative evaluation of lower rectal cancer
    Kiyomatsu, T
    Watanabe, T
    Minami, M
    Komuro, Y
    Tsurita, G
    Ohtomo, K
    Nagawa, H
    DISEASES OF THE COLON & RECTUM, 2004, 47 (06) : 1028 - 1029
  • [27] Diagnostic accuracy of multidetector-row computed tomography imaging for hepatocellular carcinoma-a validation of AASLD criteria in an Asian population
    Lim, M. S.
    Allen, J.
    Chia, G. S.
    Lim, K. C.
    Thian, Y. L.
    Thng, C. H.
    Low, A.
    Tay, K. H.
    Tan, S. B.
    Chow, P. K.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2010, 25 : A106 - A106
  • [28] Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT: correlation with histopathological findings
    Takeyuki Watadani
    Masaaki Akahane
    Takeharu Yoshikawa
    Kuni Ohtomo
    Radiation Medicine, 2008, 26 : 402 - 407
  • [29] Multiple Tracheal Diverticula Detected by Multidetector-row Computed Tomography
    Wakisaka, Masaki
    Sohma, Wataru
    Abe, Hisanori
    Kawano, Yuichiro
    Ninomiya, Shigeo
    Bandoh, Toshio
    Arita, Tsuyoshi
    Kobayashi, Michio
    Okada, Fumito
    Mori, Hiromu
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2010, 17 (04) : 359 - 361
  • [30] Assessment of myocardial infarctions using multidetector-row computed tomography
    Nikolaou, K
    Knez, A
    Sagmeister, S
    Wintersperger, BJ
    Boekstegers, P
    Steinbeck, G
    Reiser, MF
    Becker, CR
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (02) : 286 - 292