Diagnostic accuracy of multidetector-row computed tomography for hilar cholangiocarcinoma

被引:25
|
作者
Akamatsu, Nobuhisa [2 ]
Sugawara, Yasuhiko [1 ]
Osada, Hisato [3 ]
Okada, Takenori [3 ]
Itoyama, Shinji [4 ]
Komagome, Masahiko [2 ]
Shin, Nobuhiro [2 ]
Cho, Narihiro [2 ]
Ishida, Takashi [2 ]
Ozawa, Fumiaki [2 ]
Hashimoto, Daijo [2 ]
机构
[1] Univ Tokyo, Dept Surg, Grad Sch Med, Artificial Organ & Transplantat Div,Bunkyo Ku, Tokyo 1138655, Japan
[2] Saitama Med Univ, Dept Hepatobiliary Pancreat Surg, Saitama, Japan
[3] Saitama Med Univ, Dept Radiol, Saitama, Japan
[4] Saitama Med Univ, Dept Pathol, Saitama, Japan
关键词
cholangiocarcinoma; invasion; lymph node metastasis; multidetector computed tomography; sensitivity; BILE-DUCT CARCINOMA; PREOPERATIVE EVALUATION; DIRECT CHOLANGIOGRAPHY; HELICAL CT; RESECTION; RESECTABILITY; CANCER; SONOGRAPHY; MDCT; OBSTRUCTION;
D O I
10.1111/j.1440-1746.2009.06113.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: The aim of this study was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for the evaluation of tumor spread in hilar cholangiocarcinoma. Methods: Images obtained from a 16-detector row scanner of 22 patients were interpreted. The diagnostic accuracy of longitudinal ductal spread, vertical invasion (including hepatic parenchyma), and lymph node metastasis was assessed with reference to histopathological findings. Results: The location of the tumor was correctly diagnosed in 95% of cases (21/22), but in five of these cases, the cut end of the intrahepatic bile duct was positive, resulting in 77% diagnostic accuracy for longitudinal spread. Among the patients with a negative bile duct surgical margin, there was a significant difference in the measurement of tumor spread between MDCT and microscopic investigation (P < 0.001). For vertical invasion, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT were 69%, 100%, 100%, and 69% for the liver parenchyma, respectively. The sensitivity, specificity, PPV, and NPV of MDCT for lymph node metastasis were 50%, 75%, 43%, and 80%, respectively. Conclusions: The diagnostic accuracy of MDCT for tumor location and vertical invasion was satisfactory, but ductal spread was underestimated in comparison with microscopic measurements.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [1] Preoperative assessment of hilar cholangiocarcinoma by multidetector row computed tomography
    Unno, Michiaki
    Okumoto, Tadayuki
    Katayose, Yu
    Rikiyama, Toshiki
    Sato, Akihiro
    Motoi, Fuyuhiko
    Oikawa, Masaya
    Egawa, Shinichi
    Ishibashi, Tadashi
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SURGERY, 2007, 14 (05): : 434 - 440
  • [2] Multidetector-row computed tomography
    El-Khoury, GY
    Bennett, DL
    Ondr, GJ
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (01) : 1 - 5
  • [3] Usefulness of multidetector-row computed tomography
    Su, Chieh-Shou
    Tsai, I-Chen
    Lin, Wei-Wen
    Lee, Tain
    Ting, Chih-Tai
    Liang, Kae-Woei
    TEXAS HEART INSTITUTE JOURNAL, 2008, 35 (03) : 349 - 351
  • [4] Correct Diagnosis of Vascular Encasement and Longitudinal Extension of Hilar Cholangiocarcinoma by Four-Channel Multidetector-Row Computed Tomography
    Okumoto, Tadayuki
    Sato, Akihiro
    Yamada, Takayuki
    Takase, Kei
    Matsuhashi, Toshio
    Tsuda, Masashi
    Seiji, Kazumasa
    Ishibashi, Tadashi
    Higano, Shuichi
    Katayose, Yu
    Unno, Michiaki
    Takahashi, Shoki
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2009, 217 (01): : 1 - 8
  • [5] Reproducibility of multidetector-row computed tomography measurements
    Manfrini, O.
    Russo, V.
    Ceroni, L.
    Montalti, M.
    Ciavarella, A.
    Bugiardini, R.
    Fattori, R.
    EUROPEAN HEART JOURNAL, 2007, 28 : 882 - 882
  • [6] Multidetector-row computed tomography of coronary atherosclerosis
    Nikolaou, K
    Becker, CR
    Wintersperger, BJ
    Rist, C
    Trumm, C
    Leber, A
    Babaryka, G
    Reiser, MF
    RADIOLOGE, 2004, 44 (02): : 130 - +
  • [7] Detection of pannus by multidetector-row computed tomography
    Teshima, H
    Hayashida, N
    Enomoto, N
    Aoyagi, S
    Okuda, K
    Uchida, M
    ANNALS OF THORACIC SURGERY, 2003, 75 (05): : 1631 - 1633
  • [8] Multidetector-row computed tomography of thoracic trauma
    Kaewlai, R.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2011, 65 : 3 - 16
  • [9] Multidetector-row computed tomography diagnostic accuracy in the real world of cardiology: a comparison with invasive coronary angiography
    Sirol, M.
    Sanz, J. S.
    Dellagrotaglie, S.
    Poon, M.
    Fuster, V.
    Rajagopalan, S.
    Leber, A. W.
    EUROPEAN HEART JOURNAL, 2006, 27 : 428 - 429
  • [10] Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion
    Davide Ippolito
    Silvia Girolama Drago
    Cammillo Talei Franzesi
    Davide Fior
    Sandro Sironi
    World Journal of Gastroenterology, 2016, 22 (20) : 4891 - 4900