Non-invasive extended hemodynamic monitoring. Reduction of circulatory risk situations

被引:0
|
作者
Bock, M.
Sturm, T.
Motsch, J.
机构
[1] Univ Klinikum Heidelberg, Anasthesiol Klin, D-69120 Heidelberg, Germany
[2] Zent Krankenhaus Bozen, Anasthesie Abt 1, Bolzano, Italy
[3] Univ Klinikum Mannheim, Klin Anaesthesiol & Operat Intens Med, Mannheim, Germany
来源
ANAESTHESIST | 2007年 / 56卷 / 07期
关键词
cardiac index; major abdominal surgery; non-invasive; partial CO2 rebreathing method; monitoring;
D O I
10.1007/s00101-007-1189-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Cardiac output and the cardiac index (CI) are not routinely monitored during major abdominal surgery for economic as well as medical reasons. This practice, however, might be changed by the application of newer non-invasive technologies like the partial CO2 rebreathing method based on the inverse Fick's principle. In this prospective randomized study we investigated the impact of a non-invasive monitoring of CI on the incidence of hemodynamic instability and interventions by the attending anesthesiologist during major abdominal surgery. Patients and methods. Additionally to routine hemodynamic monitoring we measured CI using the partial CO2 rebreathing method in 28 patients (9 female, 19 male) undergoing major abdominal surgery. In group I the anesthesiologists were aware of the results of the extended hemodynamic monitoring and in group II the attending anesthesiologist was blinded to the information obtained by these measurements of CI. Results. Groups did not differ with regard to the baseline hemodynamic parameters. We obtained 923 measurements in both groups and 95 situations of hemodynamic instability (CI < 2.5 l/minxm(2)) were detected in group I compared to 147 situations in group II (p < 0.05). There were significantly more hemodynamic interventions in group I than in group II (p < 0.0001). The cardiac index remained higher in group I in comparison to group II (p < 0.0001). Measurement of CI was the only method to detect situations of hemodynamic instability in our setting. Conclusion. The incidence of hemodynamic instability was significantly reduced during major abdominal surgery when anesthesiologists were aware of the measurement results of extended hemodynamic monitoring.
引用
收藏
页码:656 / 664
页数:9
相关论文
共 50 条
  • [21] Invasive versus non-invasive hemodynamic monitoring of heart failure patients and their outcomes
    Fadi Kandah
    Pooja Dhruva
    Raj Shukla
    Maedeh Ganji
    Carlos Palacio
    Emil Missov
    Jose RuizMorales
    [J]. Journal of Geriatric Cardiology, 2022, 19 (04) : 315 - 318
  • [22] INVASIVE OR NON-INVASIVE MONITORING
    HUGENHOL.PG
    HEIKKILA, J
    HAGEMEIJ.F
    ARNTZENI.AC
    POOL, J
    PALADINO, D
    [J]. CIRCULATION, 1972, 46 (04) : 75 - &
  • [23] Accuracy of non-invasive and minimally invasive hemodynamic monitoring: where do we stand?
    Pour-Ghaz, Issa
    Manolukas, Theodore
    Fora, Nathalie
    Raja, Joel
    Rawal, Aranyak
    Ibebuogu, Uzoma N.
    Khouzam, Rami N.
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (17)
  • [24] Continuous non-invasive hemodynamic monitoring in early onset severe preeclampsia
    Ackerman-Banks, Christina M.
    Bhinder, Jasjit
    Eder, Maxwell
    Heerdt, Paul
    Sugeng, Lissa
    Testani, Jeffrey
    Alian, Aymen
    Lipkind, Heather
    Velazquez, Eric
    Reddy, Uma
    Chou, Josephine C.
    [J]. PREGNANCY HYPERTENSION-AN INTERNATIONAL JOURNAL OF WOMENS CARDIOVASCULAR HEALTH, 2023, 34 : 27 - 32
  • [25] Impedance cardiography a non-invasive method for hemodynamic monitoring of haemodialysed patients
    Vaduva, Cristina
    Cana-Ruiu, Daniela
    Toader, Despina
    Musetescu, Rodica
    Istrate, Natalia
    Grauntanu, Corina
    Dragan, Mary
    Mota, Eugen
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 : 324 - 324
  • [26] Non-Invasive Hemodynamic Monitoring in Hemodialysis Using Electrical Impedance Tomography
    Oh, Tongin
    Mok, Jinwon
    Moon, Ju Young
    Kim, Yang Gyun
    Lee, Sangho
    Jung, Su Woong
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 700 - 701
  • [27] Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring
    Philip Digiglio
    Ruya Li
    Wenqi Wang
    Tingrui Pan
    [J]. Annals of Biomedical Engineering, 2014, 42 : 2278 - 2288
  • [28] Non-invasive mechanical ventilation in the weaning process: continuous hemodynamic monitoring
    F Franchi
    C Palomba
    E Mastrocinque
    L Cubattoli
    P Mongelli
    E Casadei
    [J]. Critical Care, 14 (Suppl 1):
  • [29] A COMPUTER-CONTROLLED NON-INVASIVE HEMODYNAMIC MONITORING-SYSTEM
    MCMENEMIN, IM
    KENNY, GNC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (04) : 492 - 496
  • [30] Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring
    Digiglio, Philip
    Li, Ruya
    Wang, Wenqi
    Pan, Tingrui
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (11) : 2278 - 2288