Non-invasive extended hemodynamic monitoring. Reduction of circulatory risk situations

被引:0
|
作者
Bock, M.
Sturm, T.
Motsch, J.
机构
[1] Univ Klinikum Heidelberg, Anasthesiol Klin, D-69120 Heidelberg, Germany
[2] Zent Krankenhaus Bozen, Anasthesie Abt 1, Bolzano, Italy
[3] Univ Klinikum Mannheim, Klin Anaesthesiol & Operat Intens Med, Mannheim, Germany
来源
ANAESTHESIST | 2007年 / 56卷 / 07期
关键词
cardiac index; major abdominal surgery; non-invasive; partial CO2 rebreathing method; monitoring;
D O I
10.1007/s00101-007-1189-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Cardiac output and the cardiac index (CI) are not routinely monitored during major abdominal surgery for economic as well as medical reasons. This practice, however, might be changed by the application of newer non-invasive technologies like the partial CO2 rebreathing method based on the inverse Fick's principle. In this prospective randomized study we investigated the impact of a non-invasive monitoring of CI on the incidence of hemodynamic instability and interventions by the attending anesthesiologist during major abdominal surgery. Patients and methods. Additionally to routine hemodynamic monitoring we measured CI using the partial CO2 rebreathing method in 28 patients (9 female, 19 male) undergoing major abdominal surgery. In group I the anesthesiologists were aware of the results of the extended hemodynamic monitoring and in group II the attending anesthesiologist was blinded to the information obtained by these measurements of CI. Results. Groups did not differ with regard to the baseline hemodynamic parameters. We obtained 923 measurements in both groups and 95 situations of hemodynamic instability (CI < 2.5 l/minxm(2)) were detected in group I compared to 147 situations in group II (p < 0.05). There were significantly more hemodynamic interventions in group I than in group II (p < 0.0001). The cardiac index remained higher in group I in comparison to group II (p < 0.0001). Measurement of CI was the only method to detect situations of hemodynamic instability in our setting. Conclusion. The incidence of hemodynamic instability was significantly reduced during major abdominal surgery when anesthesiologists were aware of the measurement results of extended hemodynamic monitoring.
引用
收藏
页码:656 / 664
页数:9
相关论文
共 50 条
  • [11] Editorial: Less and Non-invasive Hemodynamic Monitoring Techniques
    Saugel, Bernd
    Sakka, Samir G.
    [J]. FRONTIERS IN MEDICINE, 2018, 5
  • [12] Design of microstrip patch sensor for non-invasive body electrolyte monitoring.
    Rakib, Sakhawat Hossen
    Reza, Md Taslim
    Islam, Md Fokhrul
    [J]. 2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1110 - 1113
  • [13] CONTINUOUS NON-INVASIVE HEMODYNAMIC MONITORING USING ESOPHAGEAL DOPPLER
    SINGER, M
    CLARKE, J
    BENNETT, ED
    [J]. BRITISH JOURNAL OF HOSPITAL MEDICINE, 1988, 40 (05): : 400 - 400
  • [14] THE VALUE OF NON-INVASIVE HEMODYNAMIC MONITORING DURING PEDIATRIC HEMODIALYSIS
    Vegh, Anna
    Sagat, Lorant
    Liebhardt, Agnes
    Reusz, GyOrgy S.
    [J]. PEDIATRIC NEPHROLOGY, 2022, 37 (11) : 2835 - 2835
  • [15] Non-invasive hemodynamic monitoring using USCOM in HEMS at the scene
    Knobloch, Karsten
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 62 (04): : 1069 - 1070
  • [16] Non-invasive monitoring of hemodynamic changes in orthotropic brain tumor
    Kashyap, Dheeerendra
    Sharma, Vikrant
    Liu, Hanli
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [17] Invasive versus non-invasive hemodynamic monitoring of heart failure patients and their outcomes
    Fadi Kandah
    Pooja Dhruva
    Raj Shukla
    Maedeh Ganji
    Carlos Palacio
    Emil Missov
    Jose Ruiz-Morales
    [J]. Journal of Geriatric Cardiology, 2022, (04) : 315 - 318
  • [18] Dual excitation ratiometric fluorescent sensor: Application to non-invasive bioprocess monitoring.
    Kermis, HR
    Kostov, Y
    Harms, P
    Rao, G
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U243 - U243
  • [19] Hemodynamic monitoring for liver transplantation: Agreement between invasive and non-invasive devices?
    Duarte, T. Isidoro
    Amaral, M.
    Pires, C.
    Casimiro, J.
    Germano, N.
    [J]. MEDICINA INTENSIVA, 2022, 46 (09) : 527 - 529
  • [20] Invasive versus non-invasive hemodynamic monitoring of heart failure patients and their outcomes
    Kandah, Fadi
    Dhruva, Pooja
    Shukla, Raj
    Ganji, Maedeh
    Palacio, Carlos
    Missov, Emil
    Ruiz-Morales, Jose
    [J]. JOURNAL OF GERIATRIC CARDIOLOGY, 2022, 19 (04) : 315 - 318