Impact of Deep Learning Reconstruction Combined With a Sharpening Filter on Single-Shot Fast Spin-Echo T2-Weighted Magnetic Resonance Imaging of the Uterus

被引:15
|
作者
Tsuboyama, Takahiro [1 ]
Onishi, Hiromitsu [1 ]
Nakamoto, Atsushi [1 ]
Ogawa, Kazuya [1 ]
Koyama, Yoshihiro [2 ]
Tarewaki, Hiroyuki [2 ]
Tomiyama, Noriyuki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Radiol, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Osaka Univ Hosp, Dept Radiol, Osaka, Japan
关键词
magnetic resonance imaging; T2-weighted imaging; single-shot fast spin-echo; deep learning; filter; uterus; DIAGNOSTIC CONFIDENCE; INCREASED SPEED; QUALITY; MRI;
D O I
10.1097/RLI.0000000000000847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective This study aimed to evaluate the effects of deep learning (DL) reconstruction and a postprocessing sharpening filter on the image quality of single-shot fast spin-echo (SSFSE) T2-weighted imaging (T2WI) of the uterus. Materials and Methods Fifty consecutive patients who underwent pelvic magnetic resonance imaging were included. Parasagittal T2WI with a slice thickness of 4 mm was obtained with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and SSFSE sequences (mean scan time, 204 and 22 seconds, respectively). The following 3 types of SSFSE images were reconstructed, and the signal-to-noise ratio (SNR) and tissue contrast were assessed: conventional reconstruction (SSFSE-C), DL reconstruction (SSFSE-DL), and DL with a sharpening filter (SSFSE-DLF). Three radiologists independently assessed image quality, and area under the visual grading characteristics curve (AUC(VGC)) analysis was performed to compare the SSFSE and PROPELLER images. Results Compared with that of the PROPELLER images, the SNR of the SSFSE-C, SSFSE-DL, and SSFSE-DLF images was significantly lower (P < 0.05), significantly higher (P < 0.05), and equivalent, respectively. The SSFSE-DL images exhibited significantly lower contrast between the junctional zone and myometrium than those obtained with the other sequences (P < 0.05). In qualitative comparisons with the PROPELLER images, all 3 SSFSE sequences, SSFSE-DL, and SSFSE-DLF demonstrated significantly higher scores for artifacts, noise, and sharpness, respectively (P < 0.01). The overall image quality of SSFSE-C (mean AUC(VGC), 0.03; P < 0.01) and SSFSE-DL (mean AUC(VGC), 0.23; P < 0.01) was rated as significantly inferior, whereas that of SSFSE-DLF (mean AUC(VGC), 0.69) was equivalent or significantly higher (P < 0.01). Conclusion Using a combination of DL and a sharpening filter markedly increases the image quality of SSFSE of the uterus to the level of the PROPELLER sequence.
引用
收藏
页码:379 / 386
页数:8
相关论文
共 50 条
  • [21] Single-shot fast spin-echo MR imaging of the fetus: A pictorial essay
    Huppert, BJ
    Brandt, KR
    Ramin, KD
    King, BF
    RADIOGRAPHICS, 1999, 19 : S215 - S227
  • [22] Fat-suppressed T2-weighted MRI of the liver: Comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Takahashi, M
    Sakahara, H
    Nozaki, A
    Kabasawa, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 439 - 449
  • [23] FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES
    HILFIKER, P
    ZANETTI, M
    DEBATIN, JF
    MCKINNON, G
    HODLER, J
    INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 110 - 114
  • [24] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393
  • [25] T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging
    Thomas K. Helmberger
    Julia Schröder
    Nicolaus Holzknecht
    Michaela Gregor
    Andreas Heuck
    Rainer Petsch
    Maximilian F. Reiser
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 9 : 42 - 51
  • [26] T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging
    Helmberger, Thomas K.
    Schroeder, Julia
    Holzknecht, Nicolaus
    Gregor, Michaela
    Heuck, Andreas
    Petsch, Rainer
    Reiser, Maximilian F.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1999, 9 (1-2) : 42 - 51
  • [27] Manually respiratory-triggered single-shot fast spin-echo:: a non-breath-hold T2-weighted method for liver lesion
    O'Riordan, E
    Haider, MA
    O'Malley, ME
    Khalili, K
    Ibach, K
    Lockwood, GA
    Bahadorani, B
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2003, 54 (05): : 289 - 295
  • [28] Myocardial perfusion with ultra fast spin-echo single-shot echo-planar-imaging
    Pedro Ferreira
    Peter Gatehouse
    David Firmin
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [29] Cine magnetic resonance imaging with single-shot fast spin echo for evaluation of dysphagia and aspiration
    Hartl, Dana M.
    Kolb, Frederic
    Bretagne, Evelyne
    Marandas, Patrick
    Sigal, Robert
    DYSPHAGIA, 2006, 21 (03) : 156 - 162
  • [30] Single-shot fast spin-echo diffusion tensor imaging of the lumbar spine at 1.5 and 3 T
    Carballido-Gamio, Julio
    Xu, Duan
    Newitt, David
    Han, Eric T.
    Vigneron, Daniel B.
    Majumdar, Sharmila
    MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 665 - 670