A guide to avoid method bias of chromium (III, VI) chemiluminescence determination by luminol-hydrogen peroxide reaction -: Application to water samples

被引:7
|
作者
Meseguer-Lloret, S [1 ]
Campíns-Falcó, P [1 ]
Tortajada-Genaro, LA [1 ]
Blasco-Gómez, F [1 ]
机构
[1] Univ Valencia, Fac Quim, Dept Quim Analit, E-46100 Valencia, Spain
关键词
chromium(III; IV); chemiluminescence; luminol oxidation;
D O I
10.1080/0306731031000101383
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cr(III) and/or Cr(VI) determinations based on light emission produced by luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by Cr(III) were studied in order to diagnose and/or avoid method bias. The calibration step was optimized, and the usefulness of the method for speciating chromium was tested. The use of the standard addition method in the linear interval concentration range made it possible to diagnose the accuracy of the method for real samples. Good results were obtained for several real water samples containing chromium at different concentrations. The proposed protocol made the method traceable with an appropriate certified reference material and with the reference method.
引用
收藏
页码:405 / 416
页数:12
相关论文
共 50 条
  • [21] Determination of hydrogen peroxide in water by chemiluminescence detection, (II) theoretical analysis of luminol chemiluminescence processes
    Uchida, S
    Satoh, Y
    Yamashiro, N
    Satoh, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (09) : 898 - 906
  • [22] Chemiluminescence determination of chromium(III) and total chromium in water samples using the periodate-lucigenin reaction
    Jian-Xiu Du
    Yin-Huan Li
    Rong Guan
    Microchimica Acta, 2007, 158 : 145 - 150
  • [23] Chemiluminescence determination of chromium(III) and total chromium in water samples using the periodate-lucigenin reaction
    Du, Jian-Xiu
    Li, Yin-Huan
    Guan, Rong
    MICROCHIMICA ACTA, 2007, 158 (1-2) : 145 - 150
  • [24] A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2014, 59 (04): : 2657 - 2661
  • [25] Enhanced chemiluminescence of the luminol-hydrogen peroxide system by BSA-stabilized Au nanoclusters as a peroxidase mimic and its application
    Deng, Mao
    Xu, Shuangjiao
    Chen, Funan
    ANALYTICAL METHODS, 2014, 6 (09) : 3117 - 3123
  • [26] Application of manganese-tetrasulfonatophthalo-cyanine as a new mimetic peroxidase in the determination of hydrogen peroxide by chemiluminescence reaction with luminol
    Li, YX
    Zhu, CQ
    Wang, L
    Gao, F
    Li, MG
    Wang, LY
    Zhu, YW
    ANALYTICAL LETTERS, 2001, 34 (11) : 1841 - 1850
  • [27] A novel enhancing flow-injection chemiluminescence method for the determination of glutathione using the reaction of luminol with hydrogen peroxide
    Wang, L
    Li, YX
    Zhao, DH
    Zhu, CQ
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 41 - 45
  • [28] A Novel Enhancing Flow-Injection Chemiluminescence Method for the Determination of Glutathione Using the Reaction of Luminol with Hydrogen Peroxide
    Lun Wang
    Yongxin Li
    Danhua Zhao
    Changqin Zhu
    Microchimica Acta, 2003, 141 : 41 - 45
  • [29] Spectrophotometric method for the determination of chromium (VI) in water samples
    P. Nagaraj
    N. Aradhana
    Anantharaman Shivakumar
    Ashwinee Kumar Shrestha
    Avinash k Gowda
    Environmental Monitoring and Assessment, 2009, 157 : 575 - 582
  • [30] Spectrophotometric method for the determination of chromium (VI) in water samples
    Nagaraj, P.
    Aradhana, N.
    Shivakumar, Anantharaman
    Shrestha, Ashwinee Kumar
    Gowda, Avinash K.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2009, 157 (1-4) : 575 - 582