Reliability of nitrogen dioxide passive diffusion tubes for ambient measurement:: in situ properties of the triethanolamine absorbent

被引:27
|
作者
Kirby, C
Fox, M
Waterhouse, J
机构
[1] Anglia Polytech Univ, Environm Sci Res Ctr, Cambridge CB1 1PT, England
[2] De Montfort Univ, Dept Chem, Leicester LE1 9BH, Leics, England
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2000年 / 2卷 / 04期
关键词
D O I
10.1039/b003124k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Factors concerning NO2 uptake by the absorbent triethanolamine (TEA) in NO2 diffusion tubes are examined. Although the nominal freezing point of TEA is 17.9-21.2 degrees C, we show that, for a range of aqueous TEA solutions (0-20% H2O), no freezing occurs even at -10 degrees C. Therefore NO2 collection efficiency is unlikely to be impaired by low temperature exposure. The recovery of TEA from the meshes of exposed samplers is determined as similar to 98%, even after 42 days, showing that the stability in situ of TEA is unaffected by long-term exposure. A model of a diffusion tube sampling array for simultaneous exposures, with a 0.1 m sampler spacing, shows that NO2 uptake by individual samplers is not affected by the presence of neighbouring tubes in the array. This is confirmed by sampler precision at two Cambridge sites. Four sampler preparation methods are compared for differences in NO2 uptake of exposed samplers. All methods employ TEA as absorbent, transferred by either dipping meshes in a TEA-acetone solution or pipetting aliquots of a TEA-H2O solution onto the meshes. For samplers prepared by three of the methods, no difference in NO2 uptake is found, but for samplers prepared using a 50% v/v TEA-H2O solution, a mean reduction of 18% is found. Student's t-tests show that the difference is highly significant (P less than or equal to 0.001). Reasons for the difference are discussed.
引用
收藏
页码:307 / 312
页数:6
相关论文
共 50 条
  • [41] Sub-ambient carbon dioxide adsorption properties of nitrogen doped graphene
    1600, American Institute of Physics Inc. (117):
  • [42] In situ measurement of porous silicon and the influence of ambient gas on its properties
    Bilenko, DI
    Belobrovaja, OY
    Coldobanova, OY
    Jarkova, EA
    Khasina, EI
    Polyanskaya, VP
    Melnikova, TE
    Mysenko, IB
    Smirnov, VV
    Filippova, GO
    SENSORS AND ACTUATORS A-PHYSICAL, 2000, 79 (02) : 147 - 152
  • [43] Measurement of background urban nitrogen dioxide pollution levels with passive samplers in Montpellier, France
    Bernard, NL
    Astre, CM
    Vuillot, B
    Saintot, MJ
    Gerber, MJ
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1997, 7 (02): : 165 - 178
  • [44] The measurement of the sink properties of triethanolamine (TEA) as a coating for collecting NO2 by using annular diffusion denuders
    Vichi, Francesca
    De Santis, Franco
    ENVIRONMENTAL TECHNOLOGY, 2012, 33 (09) : 1065 - 1069
  • [45] COLLABORATIVE TESTING OF A MANUAL SODIUM ARSENITE METHOD FOR MEASUREMENT OF NITROGEN-DIOXIDE IN AMBIENT AIR
    MARGESON, JH
    SUGGS, JC
    CONSTANT, PC
    SHARP, MC
    SCHEIL, GW
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1978, 12 (03) : 294 - 297
  • [47] Improving spatial nitrogen dioxide prediction using diffusion tubes: A case study in West Central Scotland
    Pannullo, Francesca
    Lee, Duncan
    Waclawski, Eugene
    Leyland, Alastair H.
    ATMOSPHERIC ENVIRONMENT, 2015, 118 : 227 - 235
  • [48] MODIFICATION OF AMAYA-SUGIURA PASSIVE SAMPLING SPECTROPHOTOMETRIC METHOD OF NITROGEN-DIOXIDE DETERMINATION IN AMBIENT AIR
    KROCHMAL, D
    GORSKI, L
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (04): : 220 - 222
  • [49] Further development of a new flow-through directional passive air sampler for monitoring ambient nitrogen dioxide
    Lin, Chun
    Timmis, Roger
    Jones, Kevin C.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (03): : 635 - 641
  • [50] PASSIVE COLORIMETRIC DOSIMETER TUBES FOR AMMONIA, CARBON-MONOXIDE, CARBON-DIOXIDE, HYDROGEN-SULFIDE, NITROGEN-DIOXIDE AND SULFUR-DIOXIDE
    MCCONNAUGHEY, PW
    MCKEE, ES
    PRITTS, IM
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (07): : 357 - 362