Reliability of nitrogen dioxide passive diffusion tubes for ambient measurement:: in situ properties of the triethanolamine absorbent

被引:27
|
作者
Kirby, C
Fox, M
Waterhouse, J
机构
[1] Anglia Polytech Univ, Environm Sci Res Ctr, Cambridge CB1 1PT, England
[2] De Montfort Univ, Dept Chem, Leicester LE1 9BH, Leics, England
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2000年 / 2卷 / 04期
关键词
D O I
10.1039/b003124k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Factors concerning NO2 uptake by the absorbent triethanolamine (TEA) in NO2 diffusion tubes are examined. Although the nominal freezing point of TEA is 17.9-21.2 degrees C, we show that, for a range of aqueous TEA solutions (0-20% H2O), no freezing occurs even at -10 degrees C. Therefore NO2 collection efficiency is unlikely to be impaired by low temperature exposure. The recovery of TEA from the meshes of exposed samplers is determined as similar to 98%, even after 42 days, showing that the stability in situ of TEA is unaffected by long-term exposure. A model of a diffusion tube sampling array for simultaneous exposures, with a 0.1 m sampler spacing, shows that NO2 uptake by individual samplers is not affected by the presence of neighbouring tubes in the array. This is confirmed by sampler precision at two Cambridge sites. Four sampler preparation methods are compared for differences in NO2 uptake of exposed samplers. All methods employ TEA as absorbent, transferred by either dipping meshes in a TEA-acetone solution or pipetting aliquots of a TEA-H2O solution onto the meshes. For samplers prepared by three of the methods, no difference in NO2 uptake is found, but for samplers prepared using a 50% v/v TEA-H2O solution, a mean reduction of 18% is found. Student's t-tests show that the difference is highly significant (P less than or equal to 0.001). Reasons for the difference are discussed.
引用
收藏
页码:307 / 312
页数:6
相关论文
共 50 条
  • [21] Measurements of nitrogen dioxide in Greenland using Palmes diffusion tubes
    Hansen, TS
    Kruse, M
    Nissen, H
    Glasius, M
    Lohse, C
    JOURNAL OF ENVIRONMENTAL MONITORING, 2001, 3 (01): : 139 - 145
  • [22] Calibration of a passive sampling device for the determination of nitrogen dioxide in ambient air
    Huynh, Thanh-Binh
    Vo-Ngoc, Bao-Thuyen
    Dang-Bao, Trung
    Tran, Thi-Kieu-Anh
    TALANTA OPEN, 2024, 9
  • [23] THE APPLICATION OF A PASSIVE PERMEATION DEVICE FOR THE MEASUREMENT OF AMBIENT SULFUR-DIOXIDE
    ORR, DB
    HIPFNER, JC
    CHAN, WH
    LUSIS, MA
    HUNT, JE
    ATMOSPHERIC ENVIRONMENT, 1987, 21 (06) : 1473 - 1475
  • [24] Development and Evaluation of a Badge-type Passive Sampler for the Measurement of Short-term Nitrogen Dioxide in Ambient Air
    Kim, Sun Kyu
    Yim, Bong Been
    Jung, Eui Suk
    Kim, Sun Tae
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2006, 22 (01) : 117 - 126
  • [25] Determination of ambient NO2 concentrations using passive diffusion tubes and automatic samplers
    Duberstein, Wesley P.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [26] Performances and Application of a Passive Sampling Method for the Simultaneous Determination of Nitrogen Dioxide and Sulfur Dioxide in Ambient Air
    H. Plaisance
    I. Sagnier
    J. Y. Saison
    J. C. Galloo
    R. Guillermo
    Environmental Monitoring and Assessment, 2002, 79 : 301 - 315
  • [27] Performances and application of a passive sampling method for the simultaneous determination of nitrogen dioxide and sulfur dioxide in ambient air
    Plaisance, H
    Sagnier, I
    Saison, JY
    Galloo, JC
    Guillermo, R
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2002, 79 (03) : 301 - 315
  • [28] A method of nitrogen dioxide and sulphur dioxide determination in ambient air by use of passive samplers and ion chromatography
    Krochmal, D
    Kalina, A
    ATMOSPHERIC ENVIRONMENT, 1997, 31 (20) : 3473 - 3479
  • [29] Comparative evaluation of nitrogen oxides and ozone passive diffusion tubes for exposure studies
    Vardoulakis, Sotiris
    Lumbreras, Julio
    Solazzo, Efisio
    ATMOSPHERIC ENVIRONMENT, 2009, 43 (16) : 2509 - 2517
  • [30] Measurement of nitrogen dioxide diffusive sampling rates for Palmes diffusion tubes using a controlled atmosphere test facility (CATFAC)
    Martin, Nicholas A.
    Helmore, Jonathan J.
    White, Samual
    Snook, Ieuan L. Barker
    Parish, Andy
    Gates, Linda S.
    ATMOSPHERIC ENVIRONMENT, 2014, 94 : 529 - 537