Objectives: To compare the efficacy and performance of the pediatric Ambu AuraOnce (Ambu AO) mask (Ambu, Copenhagen, Denmark) and i-gel mask (Intersurgical Ltd., Wokingham, United Kingdom). Methods: From May 2015 to September 2016, 112 patients, 0-14 years old, underwent elective surgery at a tertiary university hospital (Riyadh, Saudi Arabia). They were randomly assigned to the Ambu AO or i-gel group. Three groups underwent a subgroup analysis: <= 5 kg (group 1), 5.1-10.0 kg (group 2), and >10 kg (group 3). Results: The oropharyngeal leak pressure was significantly higher for the i-gel (25.4 +/- 4.1 cm H2O) than for the Ambu AO (22.5 +/- 3.9 cm H2O, p<0.001). The Ambu AO had a slightly higher ease of insertion compared to the i-gel (100% versus 94%, p=0.08) and required less manipulation (2% versus 11%, p=0.07). The Ambu AO and i-gel showed non-significant differences in performance between weight groups. There were statistically significant differences for higher leak pressure in group 2 (p=0.01) and group 3 (p=0.002) in favor of the i-gel, and for less manipulation in the Ambu AO in group 1 (p=0.04). Fiberoptic viewing was superior in group 2 for the i-gel (p=0.03) and in group 3 for the Ambu AO (p=0.02). Conclusion: Both devices demonstrated equally good performance with low morbidity. The Ambu AO had a statistical tendency towards easier insertion and less manipulation. Confirming this finding will require large scale trials.
引用
收藏
页码:482 / 490
页数:9
相关论文
共 50 条
  • [1] Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures. A randomized controlled trial (vol 38, pg 482, 2017)
    Alzahem, A. M.
    Aqil, M.
    Alzahrani, T. A.
    Aljazaeri, A. H.
    SAUDI MEDICAL JOURNAL, 2017, 38 (12) : 1267 - 1267
  • [2] Comparing i-gel and Ambu AuraOnce laryngeal mask airway in pediatric patients Reply
    Aqil, Mansoor
    Alzahem, Abdulrahman M.
    SAUDI MEDICAL JOURNAL, 2017, 38 (12) : 1262 - 1263
  • [3] Performance of the Pediatric-sized i-gel Compared with the Ambu AuraOnce Laryngeal Mask in Anesthetized and Ventilated Children
    Theiler, Lorenz G.
    Kleine-Brueggeney, Maren
    Luepold, Barbara
    Stucki, Franziska
    Seiler, Stefan
    Urwyler, Natalie
    Greif, Robert
    ANESTHESIOLOGY, 2011, 115 (01) : 102 - 110
  • [4] A randomized equivalence trial comparing the i-gel and laryngeal mask airway Supreme in children
    Jagannathan, Narasimhan
    Sommers, Katherine
    Sohn, Lisa E.
    Sawardekar, Amod
    Shah, Ravi D.
    Mukherji, Isabella I.
    Miller, Steven
    Voronov, Polina
    Seraphin, Sally
    PEDIATRIC ANESTHESIA, 2013, 23 (02) : 127 - 133
  • [5] Efficacy and safety of three inflation methods of the laryngeal mask airway Ambu® Auraonce™: a randomized controlled study
    Prim, Teresa
    Brogly, Nicolas
    Guasch, Emilia
    Diez, Jesus
    Gilsanz, Fernando
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (01) : 37 - 45
  • [6] COMPARISON OF SUPRAGLOTTIC AIRWAY DEVICE I-GEL WITH CLASSIC LARYNGEAL MASK AIRWAY AND PROSEAL LARYNGEAL MASK AIRWAY FOR SHORT SURGICAL PROCEDURES
    Gandhi, Monika
    Arora, K. K.
    Sharma, Akansha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (18): : 2222 - 2226
  • [7] Evaluation of the new supraglottic airway devices Ambu AuraOnce™ and Intersurgical i-gel™
    Heuer, J. F.
    Stiller, M.
    Rathgeber, J.
    Eich, C.
    Zuechner, K.
    Bauer, M.
    Timmermann, A.
    ANAESTHESIST, 2009, 58 (08): : 813 - 820
  • [8] Efficacy and safety of three inflation methods of the laryngeal mask airway Ambu® Auraonce™: a randomized controlled study
    Teresa Prim
    Nicolas Brogly
    Emilia Guasch
    Jesús Díez
    Fernando Gilsanz
    Journal of Clinical Monitoring and Computing, 2024, 38 : 37 - 45
  • [9] A RANDOMIZED COMPARISON OF I-GEL AND AMBU AURAGAIN TM LARYNGEAL MASK AIRWAY IN PATIENTS WITH SIMULATED CERVICAL IMMOBILIZATION
    Hur, Min
    Kim, Tae Kyong
    Lee, Hyung-Chul
    ANESTHESIA AND ANALGESIA, 2019, 128 : 17 - 20
  • [10] Fiberoptic intubation of severely obese patients through supraglottic airway: A prospective, randomized trial of the Ambu® AuraGain™ laryngeal mask vs the i-gel™ airway
    Moser, Berthold
    Keller, Christian
    Audige, Laurent
    Dave, Mital H.
    Bruppacher, Heinz R.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (02) : 187 - 194