Effect of position resolution on LoR discrimination for a dual-head Compton camera

被引:5
|
作者
Gillam, John E.
Beveridge, Toby E.
Boston, Andrew J.
Boston, Helen C.
Cooper, Reynold J.
Hall, Chris J.
Mather, Andrew R.
Nolan, Paul J.
Lewis, Rob A.
机构
[1] Monash Univ, Sch Phys, Clayton, Vic 3800, Australia
[2] Monash Univ, Monash Ctr Synchrotron Sci, Clayton, Vic 3800, Australia
[3] CLRC, Daresbury Lab, Warrington WA4 4AD, Cheshire, England
[4] Univ Liverpool, Dept Phys, Liverpool L69 7ZE, Merseyside, England
关键词
positron emission tomography; Compton camera; SmartPET;
D O I
10.1016/j.nima.2006.11.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
With the current increase in effective germanium semiconductor detection technology, a positron emission tomography system comprising two opposing HPGe detectors is under development. This type of detection offers not only improvement to some aspects of PET, but also the ability to record single-photon information in the detection process. This information can be used in stand-alone imaging, and also as an additional information source in the PET process. Discrimination based on this single-photon information was proposed; however, the effectiveness of this discrimination is dependent on the resolution of the single-photon information. Simulations of the detection system, in which the positional resolution of the interaction information is variable, was conducted. The single-photon information has then been used in the PET imaging process and its effect on image improvement shown. Much like mechanical collimation, electronic collimation may be used to remove false LoRs from an image, at the expense of efficiency. Moreover, unlike mechanical collimation, this trade off may be dynamically adjusted post data acquisition. Crown Copyright (c) 2006 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 79
页数:4
相关论文
共 50 条
  • [31] Dual-head coincidence gamma camera FDG pet in patients with colorectal and anal cancer.
    Bruun, E
    Hansen, ILK
    GASTROENTEROLOGY, 2000, 118 (04) : A257 - A257
  • [32] Blood volume distribution in patients with cirrhosis: aspects of the dual-head gamma-camera technique
    Kiszka-Kanowitz, M
    Henriksen, JH
    Moller, S
    Bendtsen, F
    JOURNAL OF HEPATOLOGY, 2001, 35 (05) : 605 - 612
  • [33] Dual-head coincidence γ camera;: 18F-FDG and 99mTc imagings
    Inoue, T
    Koyama, K
    Aoki, J
    Endo, K
    POSITRON EMISSION TOMOGRAPHY IN THE MILLENNIUM, 2000, 1197 : 171 - 177
  • [34] Assessment of 18F-fluorodeoxyglucose dual-head gamma camera in asbestos lung diseases
    Melloni, B
    Monteil, J
    Vincent, F
    Bertin, F
    Gaillard, S
    Ducloux, T
    Verbeke, S
    Maubon, A
    Vandroux, JC
    Bonnaud, F
    EUROPEAN RESPIRATORY JOURNAL, 2004, 24 (05) : 814 - 821
  • [35] Fluorine-18 FDG dual-head gamma camera coincidence imaging of radiation pneumonitis
    Lin, P
    Delaney, G
    Chu, J
    Kiat, H
    Pocock, N
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (11) : 866 - 869
  • [36] Improvement of the distortion effect in dual head PET scanner for breast imaging using an add-on Compton camera
    Lin, H.
    Chiang, C.
    Lue, K.
    Ni, Y.
    Chuang, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S386 - S387
  • [37] Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT
    Fukuchi, K
    Sago, M
    Nita, K
    Fukushima, K
    Toba, M
    Hayashida, K
    Takamiya, M
    Ishida, Y
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 919 - 925
  • [38] CEREBRAL BLOOD-FLOW QUANTITATION WITH XE-133 AND DUAL-HEAD GAMMA-CAMERA
    VILLANUEVAMEYER, J
    ALI, SA
    CESANI, F
    BRISCOE, EG
    RADIOLOGY, 1995, 197 : 251 - 252
  • [39] Spatial Resolution of Multi-Head Si/CdTe Compton Camera for Medical Application
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Watanabe, Shigeki
    Satoh, Takahiro
    Shimada, Hirofumi
    Yoshida, Yukari
    Suzuki, Yoshiyuki
    Watanabe, Shin
    Takeda, Shin-ichiro
    Aono, Hiroyuki
    Ishikawa, Shin-nosuke
    Odaka, Hiyokazu
    Takahashi, Tadayuki
    Arakawa, Kazuo
    Nakano, Takashi
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4001 - +
  • [40] A novel ultrafast cardiac scanner for myocardial perfusion imaging (MPI): Comparison with a standard dual-head camera
    Keidar, Zohar
    Kagna, Olga
    Frenkel, Alex
    Israel, Ora
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50