Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT

被引:0
|
作者
Fukuchi, K
Sago, M
Nita, K
Fukushima, K
Toba, M
Hayashida, K
Takamiya, M
Ishida, Y
机构
[1] Natl Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5658565, Japan
[2] Sumitomo Met Ind Ltd, Div Biomed, Tokyo, Japan
关键词
FDG; coincidence gamma camera imaging; PET; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of cardiac FDG imaging obtained with the dual-head coincidence gamma camera (DHC) is impaired by artifacts induced by nonuniform attenuation. This study proposed a new method (registration and segmentation method for attenuation correction [AC-RS]) to correct these attenuations in the chest region without the need for additional hardware or expensive transmission scanning equipment. Methods: Before DHC imaging, Tc-99m-tetrofosmin SPECT was performed using dual-energy acquisition from both the photopeak and Compton scatter windows. The scatter window images of the Tc-99m-tetrofosmin were then registered 3-dimensionally with the cardiac DHC images and segmented into anatomic regions to obtain body and lung contours by applying the optimal threshold method on localized histograms. Theoretic attenuation coefficient Values were assigned to the corresponding anatomic regions, and the DHC emission images were reconstructed using these attenuation correction factors. The results were quantitatively evaluated by imaging a cardiac phantom filled with a uniform solution and placed in a chest phantom. Eight nondiabetic subjects were also examined using this technique, and the results were compared with those of measured attenuation-corrected PET images. Results: Use of this technique in phantom and clinical studies decreased the degree of artifacts seen in the inferior wall activity and corrected the emission images. When the results were compared with those of PET scans, the regional relative counts of the uncorrected DHC scan did not correlate with the results of the PET scan. However, the regional relative counts of the AG-RS-corrected DHC scan exhibited a linear correlation with the results of the PET scan (r = 0.73; P < 0.001), Conclusion: Reasonably accurate attenuation-corrected cardiac DHC images can be obtained using AC-RS without the need for transmission scanning.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 50 条
  • [1] Coincidence imaging with a dual-head scintillation camera
    Patton, JA
    Turkington, TG
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (03) : 432 - 441
  • [2] Cardiac SPECT attenuation correction using an integrated x-ray CT/dual-head scintillation camera system.
    Patton, JA
    Wilk, M
    Turkington, TG
    Balan, A
    Sandler, MP
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 22P - 22P
  • [3] A novel ultrafast cardiac scanner for myocardial perfusion imaging (MPI): Comparison with a standard dual-head camera
    Keidar, Zohar
    Kagna, Olga
    Frenkel, Alex
    Israel, Ora
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [4] Evaluation of transmission measurements using CS-137 point? Sources for attenuation correction on a dual-head coincidence camera
    Enterrottacher, A
    Ziegler, S
    Wetzel, D
    Schwaiger, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1183 - 1183
  • [5] Feasibility of SPECT myocardial perfusion imaging in the super-obese using a multi-head semiconductor camera with attenuation correction
    DeCicco, Anthony E.
    Sokil, Alexis B.
    Marhefka, Gregary D.
    Reist, Kirk
    Hansen, Christopher L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (02) : 344 - 350
  • [6] Feasibility of SPECT myocardial perfusion imaging in the super-obese using a multi-head semiconductor camera with attenuation correction
    Anthony E. DeCicco
    Alexis B. Sokil
    Gregary D. Marhefka
    Kirk Reist
    Christopher L. Hansen
    Journal of Nuclear Cardiology, 2015, 22 : 344 - 350
  • [7] Planar wholebody coincidence imaging on a dual-head gamma-camera.
    DiFilippo, F
    Heller, M
    Kellar, K
    Miller, S
    Zahn, R
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 863 - 863
  • [8] Segmented attenuation correction for myocardial SPECT
    Yasuyuki Takahashi
    Kenya Murase
    Teruhito Mochizuki
    Hiroshi Higashino
    Yoshifumi Sugawara
    Akiyoshi Kinda
    Annals of Nuclear Medicine, 2004, 18 : 137 - 143
  • [9] Correction for the random coincidences in dual-head gamma camera imaging
    Brasse, D
    Comtat, C
    Trébossen, R
    Tararine, M
    Nguyen, QT
    Bendriem, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 864 - 871
  • [10] Segmented attenuation correction for myocardial SPECT
    Takahashi, Y
    Murase, K
    Mochizuki, T
    Higashino, H
    Sugawara, Y
    Kinda, A
    ANNALS OF NUCLEAR MEDICINE, 2004, 18 (02) : 137 - 143