Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT

被引:0
|
作者
Fukuchi, K
Sago, M
Nita, K
Fukushima, K
Toba, M
Hayashida, K
Takamiya, M
Ishida, Y
机构
[1] Natl Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5658565, Japan
[2] Sumitomo Met Ind Ltd, Div Biomed, Tokyo, Japan
关键词
FDG; coincidence gamma camera imaging; PET; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of cardiac FDG imaging obtained with the dual-head coincidence gamma camera (DHC) is impaired by artifacts induced by nonuniform attenuation. This study proposed a new method (registration and segmentation method for attenuation correction [AC-RS]) to correct these attenuations in the chest region without the need for additional hardware or expensive transmission scanning equipment. Methods: Before DHC imaging, Tc-99m-tetrofosmin SPECT was performed using dual-energy acquisition from both the photopeak and Compton scatter windows. The scatter window images of the Tc-99m-tetrofosmin were then registered 3-dimensionally with the cardiac DHC images and segmented into anatomic regions to obtain body and lung contours by applying the optimal threshold method on localized histograms. Theoretic attenuation coefficient Values were assigned to the corresponding anatomic regions, and the DHC emission images were reconstructed using these attenuation correction factors. The results were quantitatively evaluated by imaging a cardiac phantom filled with a uniform solution and placed in a chest phantom. Eight nondiabetic subjects were also examined using this technique, and the results were compared with those of measured attenuation-corrected PET images. Results: Use of this technique in phantom and clinical studies decreased the degree of artifacts seen in the inferior wall activity and corrected the emission images. When the results were compared with those of PET scans, the regional relative counts of the uncorrected DHC scan did not correlate with the results of the PET scan. However, the regional relative counts of the AG-RS-corrected DHC scan exhibited a linear correlation with the results of the PET scan (r = 0.73; P < 0.001), Conclusion: Reasonably accurate attenuation-corrected cardiac DHC images can be obtained using AC-RS without the need for transmission scanning.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 50 条
  • [41] TOMOGRAPHIC MYOCARDIAL PERFUSION IMAGING USING A DOUBLE CAMERA COINCIDENCE SYSTEM
    WALSH, W
    FILL, H
    BUCHIN, M
    MUELLEHNER, G
    ATKINS, F
    HARPER, P
    RESNEKOV, L
    CLINICAL RESEARCH, 1976, 24 (03): : A244 - A244
  • [42] Comparative diagnostic accuracy of gated SPECT and attenuation correction in myocardial perfusion imaging
    Holly, TA
    Parker, MA
    Leonard, SM
    Toth, BM
    Hendel, RC
    CIRCULATION, 1997, 96 (08) : 2470 - 2470
  • [43] Fluorine-18-fluorodeoxyglucose dual-head gamma camera coincidence imaging of recurrent colorectal carcinoma
    Abdel-Dayem, HM
    Radin, AI
    Luo, JQ
    Marans, HY
    Wong, S
    Naddaf, SY
    El-Zeftawy, HM
    Omar, WS
    Mithilesh, K
    Abujudeh, H
    Atay, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (04) : 654 - 656
  • [44] Singles-transmission attenuation correction for dual head coincidence imaging.
    Shao, L
    Nellemann, P
    Muehllehner, G
    Bertelsen, H
    Hines, H
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 37P - 37P
  • [45] PET with a dual-head coincidence camera: Spatial resolution, scatter fraction, and sensitivity
    Kunze, WD
    Baehre, M
    Richter, E
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (06) : 1067 - 1074
  • [46] CT-attenuation correction in myocardial perfusion SPECT using a hybrid SPECT/CT
    Namdar, M
    Siegrist, PT
    Koepfli, P
    Tschuetscher, P
    Hany, TF
    Kaufmann, PA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S261 - S261
  • [47] Role of attenuation corrected dual head gamma camera coincidence imaging in nuclear oncology
    El Haddad, SI
    El Haddad, SI
    Moustafa, H
    Dayem, HA
    Youssef, SS
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S342 - S342
  • [48] Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging
    Wells, R. Glenn
    Trottier, Mikael
    Premaratne, Manuja
    Vanderwerf, Karen
    Ruddy, Terrence D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (02) : 616 - 624
  • [49] Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging
    R. Glenn Wells
    Mikael Trottier
    Manuja Premaratne
    Karen Vanderwerf
    Terrence D. Ruddy
    Journal of Nuclear Cardiology, 2018, 25 : 616 - 624
  • [50] Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging
    Dewan, Ambuj
    Ali, Iftikhar
    Ruddy, Terrence
    Wells, R.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50