A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea

被引:4
|
作者
Kim, Seok-Hyun [1 ]
Jeong, Hakgeun [1 ]
Cho, Soo [1 ]
机构
[1] Korea Inst Energy Res, Energy ICT ESS Lab, Daejeon 34101, South Korea
关键词
window thermal performance; U-value; window type; simulation performance test; actual physical performance test; ENERGY PERFORMANCE; OFFICE BUILDINGS; DESIGN OPTIMIZATION; VISUAL COMFORT; ELEMENTS; SYSTEMS;
D O I
10.3390/en12203822
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The interest in zero energy buildings is increasing in South Korea. Zero energy buildings need to save energy by using passive technology. The window performance is important to the thermal insulation of the building. Also, the government regulates the window performance through regulation and standards. However, it is difficult to predict window performance because the components of the window have become complicated due to the various materials used in the glass and frame. Based on window performance standards and regulations, the quality of window performance was managed. In this research, to consider thermal performance in proper window design in South Korea, we confirmed the impact on the thermal performance of the window through various kinds of materials and shapes. The authors also propose a window shape classification and frame calculation method based on actual test results. The authors analyzed the thermal performance data of the windows provided by the Korea Energy Agency and confirmed the change in the thermal performance of the windows by year and by frame material. The average U-value of the window decreased from 2012 to 2015 and maintained similar values until 2017. In 2018, this value was decreased to comply. Also, the authors confirmed the U-value of the windows through actual physical experiments and confirmed the change in thermal performance by the construction of the windows based on the results. The results show, in the case of aluminum windows, the U-value corresponding to Grade 3 (1.4-2.1 W/m(2)K) was as high as about 60%. Regarding the analyzed results of the U-values of PVC windows, Grade 3 (U-value of 1.4-2.1 W/m(2)K) accounted for about 35%, and Grade 2 (U-value of 1.0-1.4 W/m(2)K) for about 29%. This paper also confirmed that the frame U-value of the PVC windows is lower than the frame U-value of the aluminum windows. Therefore, the authors proposed the performance index of the glazing part in PVC and aluminum window design. The results of this research can be used as basic data to identify problems in the method of determining the performance of windows in Korea.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Seasonal thermal performance analysis of glazed window filled with paraffin including various nanoparticles
    Zhang, Guojun
    Wang, Zemei
    Li, Dong
    Wu, Yangyang
    Arici, Muslum
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (04) : 3008 - 3019
  • [42] Thermal Performance Analysis of Windows, Based on Argon Gas Percentages between Window Glasses
    Cho, Kyungjoo
    Cho, Dongwoo
    Koo, Bokyoung
    Yun, Yosun
    BUILDINGS, 2023, 13 (12)
  • [43] Thermal performance of natural airflow window in subtropical and temperate climate zones - A comparative study
    Chow, Tin-tai
    Lin, Zhang
    Fong, Kwong-fai
    Chan, Lok-shun
    He, Miao-miao
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (08) : 1884 - 1890
  • [44] Modeling study on the thermal performance of a modified cavity receiver with glass window and secondary reflector
    Chang, Huawei
    Duan, Chen
    Wen, Ke
    Liu, Yuting
    Xiang, Can
    Wan, Zhongmin
    He, Sinian
    Jing, Changwei
    Shu, Shuiming
    ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 1362 - 1369
  • [45] Summer study on thermal performance of an exhausting airflow window in evaporatively-cooled buildings
    Khalvati, F.
    Omidvar, A.
    APPLIED THERMAL ENGINEERING, 2019, 153 : 147 - 158
  • [46] A Study on New and Renewable Energy Policy Changes and Market Analysis in Korea
    An, Sang Min
    Kim, Joo Han
    Park, Myung Kyu
    Lee, Kyung Hoi
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 1500 - 1509
  • [47] The 3Cat-4 Spacecraft Thermal Analysis and Thermal Vacuum Test Campaign Results
    Buitrago-Leiva, Jeimmy Nataly
    Terraza-Palanca, Ines
    Contreras-Benito, Luis
    Fernandez, Lara
    Gracia-Sola, Guillem
    Sancho, Cristina del Castillo
    Ha, Lily
    Palma, David
    Solyga, Malgorzata
    Camps, Adriano
    AEROSPACE, 2024, 11 (10)
  • [48] Physical Activity Trajectories and Associated Changes in Physical Performance in Older Men: The MrOS Study
    Laddu, Deepika R.
    Parimi, Neeta
    Stone, Katie L.
    Lapidus, Jodi
    Hoffman, Andrew R.
    Stefanick, Marcia L.
    Langsetmo, Lisa
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2020, 75 (10): : 1967 - 1973
  • [49] THE NURSING HOME PHYSICAL PERFORMANCE TEST: AN ITEM RESPONSE THEORY ANALYSIS
    Perera, S.
    Nace, D.
    Resnick, N.
    Greenspan, S.
    GERONTOLOGIST, 2016, 56 : 709 - 709
  • [50] MEASUREMENT OF FENESTRATION NET ENERGY PERFORMANCE - CONSIDERATIONS LEADING TO DEVELOPMENT OF THE MOBILE WINDOW THERMAL TEST (MOWITT) FACILITY
    KLEMS, JH
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (03): : 208 - 216