A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea

被引:4
|
作者
Kim, Seok-Hyun [1 ]
Jeong, Hakgeun [1 ]
Cho, Soo [1 ]
机构
[1] Korea Inst Energy Res, Energy ICT ESS Lab, Daejeon 34101, South Korea
关键词
window thermal performance; U-value; window type; simulation performance test; actual physical performance test; ENERGY PERFORMANCE; OFFICE BUILDINGS; DESIGN OPTIMIZATION; VISUAL COMFORT; ELEMENTS; SYSTEMS;
D O I
10.3390/en12203822
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The interest in zero energy buildings is increasing in South Korea. Zero energy buildings need to save energy by using passive technology. The window performance is important to the thermal insulation of the building. Also, the government regulates the window performance through regulation and standards. However, it is difficult to predict window performance because the components of the window have become complicated due to the various materials used in the glass and frame. Based on window performance standards and regulations, the quality of window performance was managed. In this research, to consider thermal performance in proper window design in South Korea, we confirmed the impact on the thermal performance of the window through various kinds of materials and shapes. The authors also propose a window shape classification and frame calculation method based on actual test results. The authors analyzed the thermal performance data of the windows provided by the Korea Energy Agency and confirmed the change in the thermal performance of the windows by year and by frame material. The average U-value of the window decreased from 2012 to 2015 and maintained similar values until 2017. In 2018, this value was decreased to comply. Also, the authors confirmed the U-value of the windows through actual physical experiments and confirmed the change in thermal performance by the construction of the windows based on the results. The results show, in the case of aluminum windows, the U-value corresponding to Grade 3 (1.4-2.1 W/m(2)K) was as high as about 60%. Regarding the analyzed results of the U-values of PVC windows, Grade 3 (U-value of 1.4-2.1 W/m(2)K) accounted for about 35%, and Grade 2 (U-value of 1.0-1.4 W/m(2)K) for about 29%. This paper also confirmed that the frame U-value of the PVC windows is lower than the frame U-value of the aluminum windows. Therefore, the authors proposed the performance index of the glazing part in PVC and aluminum window design. The results of this research can be used as basic data to identify problems in the method of determining the performance of windows in Korea.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] CYCLICAL CHANGES IN PHYSICAL PROPERTIES OF CERVICAL MUCUS AND RESULTS OF POSTCOITAL TEST
    GIBOR, Y
    GARCIA, CJ
    COHEN, MR
    SCOMMEGN.A
    FERTILITY AND STERILITY, 1970, 21 (01) : 20 - &
  • [12] Studies on test results for thermal performance of solar collectors in China
    Sun Zhifeng
    Bin, Lu
    Tao, He
    Zhong, Li
    Feng Airong
    Lei, Zhang
    Huang Zhulian
    Yu, Deng
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 716 - 720
  • [13] Thermal Analysis and Verification Test of the Entrance Window Assembly for Space Solar Observatory
    Wang Chenjie
    Tao Wenquan
    Yang Wengang
    Ma Yixin
    Qin Dejin
    Li Fu
    ACTA PHOTONICA SINICA, 2022, 51 (04) : 217 - 230
  • [14] Comparative performance analysis of Vacuum Insulation Panels in thermal window shutters
    Hashemi, Arman
    Alam, Mahmood
    Ip, Kenneth
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES), 2019, 157 : 837 - 843
  • [15] A study on the proposes of energy analysis indicator by the window elements of office buildings in Korea
    Kim, Seok-Hyun
    Kim, Sun-Sook
    Kim, Kwang-Woo
    Cho, Young-Hum
    ENERGY AND BUILDINGS, 2014, 73 : 153 - 165
  • [16] CHANGES IN PHYSICAL ACTIVITY IN THE RETIREMENT WINDOW: A THEORY-BASED INTERVIEW STUDY
    McDonald, Suzanne
    Sniehotta, Falko
    White, Martin
    Hobbs, Nicola
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2012, 20 : S192 - S193
  • [17] Experimental study on thermal performance of finned tube water flow window
    Lyu, Yuanli
    Wang, Ting
    Peng, Hao
    Zheng, Shukui
    Qi, Xuejun
    Su, Hua
    Chow, Tintai
    RENEWABLE ENERGY, 2023, 219
  • [18] AIRFLOW WINDOW: NUMERICAL STUDY AND SENSIBILITY ANALYSIS OF THERMAL PERFORMANCES
    Greffet, Remy
    Salagnac, Patrick
    Michaux, Ghislain
    Ridoret, Jean-Baptiste
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 411 - 418
  • [19] CHANGES IN THE RESULTS OF THE NBT REDUCTION TEST UNDER VARYING CONDITIONS OF THE TEST-PERFORMANCE
    GORDIENKO, SM
    AVDYUNICHEVA, OE
    LABORATORNOE DELO, 1986, (11): : 660 - 666
  • [20] Performance changes during repeated military occupational test and its associations to physical performance
    Ojanen, Tommi
    Pihlainen, Kai
    Vaara, Jani P.
    Kyroelaeinen, Heikki
    ERGONOMICS, 2023, 66 (12) : 2223 - 2231