A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea

被引:4
|
作者
Kim, Seok-Hyun [1 ]
Jeong, Hakgeun [1 ]
Cho, Soo [1 ]
机构
[1] Korea Inst Energy Res, Energy ICT ESS Lab, Daejeon 34101, South Korea
关键词
window thermal performance; U-value; window type; simulation performance test; actual physical performance test; ENERGY PERFORMANCE; OFFICE BUILDINGS; DESIGN OPTIMIZATION; VISUAL COMFORT; ELEMENTS; SYSTEMS;
D O I
10.3390/en12203822
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The interest in zero energy buildings is increasing in South Korea. Zero energy buildings need to save energy by using passive technology. The window performance is important to the thermal insulation of the building. Also, the government regulates the window performance through regulation and standards. However, it is difficult to predict window performance because the components of the window have become complicated due to the various materials used in the glass and frame. Based on window performance standards and regulations, the quality of window performance was managed. In this research, to consider thermal performance in proper window design in South Korea, we confirmed the impact on the thermal performance of the window through various kinds of materials and shapes. The authors also propose a window shape classification and frame calculation method based on actual test results. The authors analyzed the thermal performance data of the windows provided by the Korea Energy Agency and confirmed the change in the thermal performance of the windows by year and by frame material. The average U-value of the window decreased from 2012 to 2015 and maintained similar values until 2017. In 2018, this value was decreased to comply. Also, the authors confirmed the U-value of the windows through actual physical experiments and confirmed the change in thermal performance by the construction of the windows based on the results. The results show, in the case of aluminum windows, the U-value corresponding to Grade 3 (1.4-2.1 W/m(2)K) was as high as about 60%. Regarding the analyzed results of the U-values of PVC windows, Grade 3 (U-value of 1.4-2.1 W/m(2)K) accounted for about 35%, and Grade 2 (U-value of 1.0-1.4 W/m(2)K) for about 29%. This paper also confirmed that the frame U-value of the PVC windows is lower than the frame U-value of the aluminum windows. Therefore, the authors proposed the performance index of the glazing part in PVC and aluminum window design. The results of this research can be used as basic data to identify problems in the method of determining the performance of windows in Korea.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Measurement results and experimental analysis study of the thermal balance of a window
    Fissore, Adequi
    Fonseca, Nestor
    BUILDING AND ENVIRONMENT, 2007, 42 (10) : 3570 - 3581
  • [2] A test method to evaluate the thermal performance of window glazings
    Alvarez, G
    Palacios, MJ
    Flores, JJ
    APPLIED THERMAL ENGINEERING, 2000, 20 (09) : 803 - 812
  • [3] Thermal performance of an electrochromic smart window tested in an environmental test cell
    Piccolo, A.
    ENERGY AND BUILDINGS, 2010, 42 (09) : 1409 - 1417
  • [4] Thermal Performance Analysis of BIPV-PDLC Window
    Ghosh, Aritra
    Sundaram, Senthilarasu
    Mallick, Tapas K.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 1708 - 1714
  • [5] Analysis of Window Components Affecting U-Value Using Thermal Transmittance Test Results and Multiple Linear Regression Analysis
    No, Sang-Tae
    Seo, Jun-Sik
    ADVANCES IN CIVIL ENGINEERING, 2018, 2018
  • [6] Advanced thermal simulator testing: Thermal analysis and test results
    Bragg-Sitton, Shannon M.
    Dickens, Ricky
    Dixon, David
    Reid, Robert
    Adams, Mike
    Davis, Joe
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM STAIF 2008, 2008, 969 : 403 - 414
  • [7] Study on Thermal Performance of Insulating Glass Window with Blind Inside
    Li, Shengjie
    Yan, Zengfeng
    Peng, Junzhi
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 411 - 418
  • [8] LCP HEATER THERMAL PERFORMANCE-TEST RESULTS AND UNIQUE TEST TECHNIQUES
    BAILEY, RE
    CHRISTENSEN, EH
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (01) : 486 - 489
  • [9] Longitudinal Changes In US Army Physical Fitness Test Performance
    Lyons, Kaitlin D.
    Pierce, Joseph R.
    Jones, Bruce H.
    Canham-Chervak, Michelle
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 8 - 9
  • [10] Development of Physical Models Describing Changes in Tightening Performance due to Thermal Stress under Thermal Shock Test Condition and Experimental Verification
    Lee, Ju Yub
    Kim, Seo Gyeom
    Wei, Shin Hwan
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2021, 45 (11) : 993 - 1000