Bend relief fenestration might prevent outflow graft obstruction in patients with left ventricular assist device

被引:4
|
作者
Faerber, Gloria [1 ]
Kirov, Hristo [1 ]
Schwan, Imke [1 ]
Graeger, Stephanie [2 ]
Diab, Mahmoud [1 ]
Tkebuchava, Sophie [1 ]
Doenst, Torsten [1 ]
机构
[1] Friedrich Schiller Univ, Jena Univ Hosp, Dept Cardiothorac Surg, Klinikum 1, D-07747 Jena, Germany
[2] Friedrich Schiller Univ, Jena Univ Hosp, Dept Radiol, Jena, Germany
关键词
Left ventricular assist device; External outflow graft obstruction; SOCIETY;
D O I
10.1093/icvts/ivac149
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Patients with left ventricular assist devices may experience external obstruction of the outflow graft through a gelatinous substance within the bend relief (BR; a stiff tube graft guiding the outflow graft). Preventative strategies have been missing. Having faced this problem, we decided to fenestrate the BR to avoid outflow graft obstruction (OGO). METHODS: Since December 2010, 167 patients underwent left ventricular assist device implantation using HeartMate II or 3. BR fenestration was introduced on July 2018 (108 patients before, 59 after the introduction of BR fenestration). Follow-up computed tomography scans were obtained from all patients and were screened for OGO by 3 independent investigators. Results were correlated with log file history, echocardiographic and clinical outcomes. RESULTS: Demographic data were comparable between groups, with mostly male patients. Patients with BR fenestration were older [63 (standard deviation (SD):10.6) vs 58 (SD: 10.7) years] and had shorter support duration [494 (SD: 383) vs 951 (SD: 875) days]. OGO was observed in 5 patients and occurred only in patients without fenestration. Importantly, it occurred late on postoperative Days 412, 462, 1043, 1184 and 1506. Three patients are still asymptomatic. Surgical revision was required in the other 2 patients for pump thrombosis or continuous low flow. One of them died 36 days after revision due to right heart failure. CONCLUSIONS: Our results suggest that fenestration of the BR may be a preventative strategy to avoid external OGO. OGO occurred late, which suggests a careful long-term follow-up.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Percutaneous Endovascular Intervention for Left Ventricular Assist Device Outflow Graft Obstruction: A Single-Center Experience
    Wallace, Ryan
    Rogers, Toby
    Sheikh, Farooq
    Balsara, Keki
    Slack, Michael
    Weissman, Gaby
    Satler, Lowell
    Waksman, Ron
    Ben-Dor, Itsik
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B86 - B86
  • [42] Outflow Graft Obstruction of the Heart Ware HVAD Left Ventricular Assist Device: A Single Center Case Series
    Young, R. K.
    Majure, D. T.
    Sheikh, F. H.
    Rodrigo, M. E.
    Weigold, G.
    Najjar, S. S.
    Boyce, S. W.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S265 - S265
  • [43] Left Ventricular Assist Device Outflow Graft Obstruction: A Complication Specific to Polytetrafluoroethylene Covering. A Word of Caution!
    Alnabelsi, Talal
    Shafii, Alexis E.
    Gurley, John C.
    Dulnuan, Kenneth
    Harris, Dwight D., II
    Guglin, Maya
    ASAIO JOURNAL, 2019, 65 (06) : E58 - E62
  • [44] Applying a clampless haemostatic device for left ventricular assist device outflow graft anastomosis
    Mehdiani, Arash
    Albert, Alexander
    Lichtenberg, Artur
    Saeed, Diyar
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (05) : 1009 - 1010
  • [45] Influence of the Outflow Graft Position on Thromboembolic and Bleeding Complications in Patients with a Left Ventricular Assist Device
    Peek, J. J.
    Zijderhand, C.
    Sjatskig, J.
    Van der Heiden, C.
    Constantinescu, A. A.
    Brugts, J. J.
    Manintveld, O. C.
    Birim, O.
    Bekkers, J.
    Mahtab, E. A.
    Bogers, A. J.
    Caliskan, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S65 - S65
  • [46] Interventional Outflow Graft Closure in Patients With Left Ventricular Assist Device Unsuitable for Surgical Explantation
    Sandri, Marcus
    Majunke, Nicolas
    Wilde, Johannes
    Lurz, Philipp
    Thiele, Holger
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B332 - B332
  • [47] Surgical Correction of Left Ventricular Assist Device Outflow Graft Obstruction Caused by a Wrapped Expanded Polytetrafluoroethylene Graft: A Case Report
    Kim, Sung Min
    Park, Ilkun
    Oh, Siwon
    Seo, Hyo Won
    Jeong, Ga Hee
    Lee, Jun Ho
    Chung, Su Ryeun
    Sung, Kiick
    Kim, Wook Sung
    Cho, Yang Hyun
    JOURNAL OF CHEST SURGERY, 2024, 57 (04): : 413 - 417
  • [48] Gore-Tex Mesh as Cause for Distal Outflow Graft Obstruction in Ventricular Assist Device Patients
    Bhattacharya, S.
    Colaco, N.
    Coleman, M.
    Sharma, S.
    Kassemos, M.
    Aras, M.
    Selby, V.
    De Marco, T.
    Klein, L.
    Wieselthaler, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S355 - S355
  • [49] Late outflow graft stenosis of left ventricular assist device and endovascular treatment
    Karaca, Sedat
    Erdinli, Dilek
    Kahraman, Umit
    Cinar, Celal
    Engin, Cagatay
    Yagdi, Tahir
    Ozbaran, Mustafa
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (02) : 154 - 158
  • [50] Minimally invasive embolectomy of HeartWare left ventricular assist device outflow graft
    Mutlak, Haitham
    Assmus, Birgit
    Popov, Aron-Frederik
    JOURNAL OF THORACIC DISEASE, 2019, 11 : S957 - S959