Efficacy of antimicrobial-impregnated external ventricular drain catheters: a prospective, randomized, controlled trial

被引:232
|
作者
Zabramski, JM
Whiting, D
Darouiche, RO
Horner, TG
Olson, J
Robertson, C
Hamilton, AJ
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Div Neurosurg, Phoenix, AZ USA
[2] Allegheny Gen Hosp, Dept Neurosurg, Pittsburgh, PA 15212 USA
[3] Baylor Coll Med, Ctr Prostheses Infect, Houston, TX 77030 USA
[4] Methodist Hosp, Indianapolis Neurosurg Grp, Indianapolis, IN USA
[5] Emory Clin, Dept Neurosurg, Atlanta, GA 30322 USA
[6] Ben Taub Gen Hosp, Dept Neurosurg, Houston, TX 77030 USA
[7] Univ Arizona, Hlth Sci Ctr, Div Neurosurg, Tucson, AZ USA
关键词
external ventricular drain; catheter; antibiotic; cerebrospinal fluid; infection; multiinstitutional study;
D O I
10.3171/jns.2003.98.4.0725
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Catheter-related infection of the cerebrospinal fluid (CSF) pathways is a potentially life-threatening complication of external ventricular drainage. A major source of infection is bacterial contamination along the external ventricular drain (EVD) catheter track. The authors examined the efficacy of EVD catheters impregnated with minocycline and rifampin in preventing these catheter-related infections. Methods. The authors conducted a prospective, randomized clinical trial at six academic medical centers. All hospitalized patients 18 years or older who required placement of an EVD catheter were eligible for inclusion in the study. Patients were randomly assigned to undergo placement of an EVD with a catheter impregnated with minocycline and rifampin or a standard untreated catheter (control group). To assess primary outcome, CSF samples were collected using a sterile technique at the time of catheter insertion, at least every 72 hours while the catheter remained in place, and at the time of catheter removal. At the time of removal, CSF cultures were obtained from the tip and tunneled segments of each catheter by performing semiquantitative roll-plate and quantitative sonication techniques. Of the 306 patients enrolled in the study, data from 288 were included in the final analysis. Eighteen patients were excluded from analysis: 14 because the ventricular catheter was in place less than 24 hours, and four because CSF cultures obtained at the time of catheter insertion were positive for infection. Of these 288 patients, 139 were assigned to the control group and 149 to the treatment group. The two groups were well matched with respect to all clinical characteristics, including patient sex and mean age, indication for catheter placement, and length of time the catheter remained in place. The antibiotic-impregnated catheters were one half as likely to become colonized as the control catheters (17.9 compared with 36.7%, respectively, p < 0.0012). Positive CSF cultures were seven times less frequent in patients with antibiotic-impregnated catheters compared with those in the control group (1.3 compared with 9.4%, respectively, p = 0.002). Conclusions. The use of EVD catheters impregnated with minocycline and rifampin can significantly reduce the risk of catheter-related infections.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [41] Cefepime vs. Ampicillin/Sulbactam and Aztreonam as antibiotic prophylaxis in neurosurgical patients with external ventricular drain: result of a prospective randomized controlled clinical trial
    Wong, G. K. C.
    Poon, W. S.
    Lyon, D.
    Wai, S.
    JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 2006, 31 (03) : 231 - 235
  • [43] A prospective randomized controlled trial of Wallace and Rocket embryo transfer catheters
    EI-Shawarby, Salem A.
    Ravhon, Amir
    Skull, Jonathan
    Ellenbogen, Adrian
    Trew, Geoffrey
    Lavery, Stuart
    REPRODUCTIVE BIOMEDICINE ONLINE, 2008, 17 (04) : 549 - 552
  • [44] Benefits of minocycline and rifampin-impregnated central venous catheters -: A prospective, randomized, double-blind, controlled, multicenter trial
    León, C
    Ruiz-Santana, S
    Rello, J
    Torre, M
    Vallés, J
    Alvarez-Lerma, F
    Sierra, R
    Saavedra, P
    Alvarez-Salgado, F
    INTENSIVE CARE MEDICINE, 2004, 30 (10) : 1891 - 1899
  • [45] Are antimicrobial-impregnated catheters effective? Replace the water and grab your washcloth, because we have a baby to wash
    McConnell, SA
    Gubbins, PO
    Anaissie, EJ
    CLINICAL INFECTIOUS DISEASES, 2004, 39 (12) : 1829 - 1833
  • [46] Antimicrobial-impregnated and -coated shunt catheters for prevention of infections in patients with hydrocephalus: a systematic review and meta-analysis
    Konstantelias, Athanasios A.
    Vardakas, Konstantinos Z.
    Polyzos, Konstantinos A.
    Tansarli, Giannoula S.
    Falagas, Matthew E.
    JOURNAL OF NEUROSURGERY, 2015, 122 (05) : 1096 - 1112
  • [47] Comment on: Durability of antimicrobial activity of antibiotic-impregnated external ventricular drains: a prospective study
    Bayston, Roger
    Ashraf, Waheed
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2020, 75 (03) : 778 - 779
  • [48] Comment on: Durability of antimicrobial activity of antibiotic-impregnated external ventricular drains: a prospective study
    Bayston, Roger
    Ashraf, Waheed
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2020, 75 (06) : 1661 - 1662
  • [49] Safety and efficacy of midline catheters versus peripheral intravenous catheters: A pilot randomized controlled trial
    Marsh, Nicole
    Larsen, Emily N.
    O'Brien, Catherine
    Ware, Robert S.
    Kleidon, Tricia M.
    Groom, Peter
    Hewer, Barbara
    Alexandrou, Evan
    Flynn, Julie
    Woollett, Kaylene
    Rickard, Claire M.
    INTERNATIONAL JOURNAL OF NURSING PRACTICE, 2023, 29 (02)
  • [50] Erratum to: Reduction in external ventricular drain infection rate. Impact of a minimal handling protocol and antibiotic-impregnated catheters
    Mónica Rivero-Garvía
    Javier Márquez-Rivas
    Manuel Enrique Jiménez-Mejías
    Olaf Neth
    Ana Belén Rueda-Torres
    Acta Neurochirurgica, 2011, 153 : 1157 - 1157