Efficacy of antimicrobial-impregnated external ventricular drain catheters: a prospective, randomized, controlled trial

被引:232
|
作者
Zabramski, JM
Whiting, D
Darouiche, RO
Horner, TG
Olson, J
Robertson, C
Hamilton, AJ
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Div Neurosurg, Phoenix, AZ USA
[2] Allegheny Gen Hosp, Dept Neurosurg, Pittsburgh, PA 15212 USA
[3] Baylor Coll Med, Ctr Prostheses Infect, Houston, TX 77030 USA
[4] Methodist Hosp, Indianapolis Neurosurg Grp, Indianapolis, IN USA
[5] Emory Clin, Dept Neurosurg, Atlanta, GA 30322 USA
[6] Ben Taub Gen Hosp, Dept Neurosurg, Houston, TX 77030 USA
[7] Univ Arizona, Hlth Sci Ctr, Div Neurosurg, Tucson, AZ USA
关键词
external ventricular drain; catheter; antibiotic; cerebrospinal fluid; infection; multiinstitutional study;
D O I
10.3171/jns.2003.98.4.0725
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Catheter-related infection of the cerebrospinal fluid (CSF) pathways is a potentially life-threatening complication of external ventricular drainage. A major source of infection is bacterial contamination along the external ventricular drain (EVD) catheter track. The authors examined the efficacy of EVD catheters impregnated with minocycline and rifampin in preventing these catheter-related infections. Methods. The authors conducted a prospective, randomized clinical trial at six academic medical centers. All hospitalized patients 18 years or older who required placement of an EVD catheter were eligible for inclusion in the study. Patients were randomly assigned to undergo placement of an EVD with a catheter impregnated with minocycline and rifampin or a standard untreated catheter (control group). To assess primary outcome, CSF samples were collected using a sterile technique at the time of catheter insertion, at least every 72 hours while the catheter remained in place, and at the time of catheter removal. At the time of removal, CSF cultures were obtained from the tip and tunneled segments of each catheter by performing semiquantitative roll-plate and quantitative sonication techniques. Of the 306 patients enrolled in the study, data from 288 were included in the final analysis. Eighteen patients were excluded from analysis: 14 because the ventricular catheter was in place less than 24 hours, and four because CSF cultures obtained at the time of catheter insertion were positive for infection. Of these 288 patients, 139 were assigned to the control group and 149 to the treatment group. The two groups were well matched with respect to all clinical characteristics, including patient sex and mean age, indication for catheter placement, and length of time the catheter remained in place. The antibiotic-impregnated catheters were one half as likely to become colonized as the control catheters (17.9 compared with 36.7%, respectively, p < 0.0012). Positive CSF cultures were seven times less frequent in patients with antibiotic-impregnated catheters compared with those in the control group (1.3 compared with 9.4%, respectively, p = 0.002). Conclusions. The use of EVD catheters impregnated with minocycline and rifampin can significantly reduce the risk of catheter-related infections.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [31] In vitro study of factors influencing the duration of antimicrobial protection of antimicrobial-impregnated external ventricular drains (vol 77, pg 682, 2022)
    Lang, Elodie
    Hulin, Anne
    Egbeola-Martial, Julia
    Woerther, Paul-Louis
    Drouard, Leonard
    Roujansky, Ariane
    Tomberli, Francoise
    Bardon, Jean
    Schimpf, Caroline
    Senova, Suhan
    Cook, Fabrice
    Lebeaux, David
    Mounier, Roman
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2022, 77 (08) : 2313 - 2313
  • [32] Comparison of Two Antibiotic-Impregnated Ventricular Catheters: A Prospective Sequential Series Trial
    Abla, Adib A.
    Zabramski, Joseph M.
    Jahnke, Heidi K.
    Fusco, David
    Nakaji, Peter
    NEUROSURGERY, 2011, 68 (02) : 437 - 442
  • [33] Do antimicrobial-impregnated central venous catheters prevent catheter-related bloodstream infection?
    McConnell, SA
    Gubbins, PO
    Anaissie, EJ
    CLINICAL INFECTIOUS DISEASES, 2003, 37 (01) : 65 - 72
  • [34] Antimicrobial-impregnated central venous catheters for prevention of catheter-related bloodstream infection in newborn infants
    Balain, Munisha
    Oddie, Sam J.
    McGuire, William
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (09):
  • [35] Does release of antimicrobial agents from impregnated external ventricular drainage catheters affect the diagnosis of ventriculitis?
    Bayston, Roger
    Ashraf, Waheed
    Ortori, Catherine
    JOURNAL OF NEUROSURGERY, 2016, 124 (02) : 375 - 381
  • [36] In vitro activity of antimicrobial-impregnated catheters against biofilms formed by KPC-producing Klebsiella pneumoniae
    de Sousa, J. K. T.
    Haddad, J. P. A.
    de Oliveira, A. C.
    Vteira, C. D.
    dos Santos, S. G.
    JOURNAL OF APPLIED MICROBIOLOGY, 2019, 127 (04) : 1018 - 1027
  • [37] Prevention of nosocomial bloodstream infections: Effectiveness of antimicrobial-impregnated and heparin-bonded central venous catheters
    Marin, MG
    Lee, JC
    Skurnick, JH
    CRITICAL CARE MEDICINE, 2000, 28 (09) : 3332 - 3338
  • [38] Durability of antimicrobial activity of antibiotic-impregnated external ventricular drains: a prospective study
    Mounier, Roman
    Lang, Elodie
    Hulin, Anne
    Woerther, Paul-Louis
    Lobo, David
    Martin, Mathieu
    Bitot, Valerie
    Flores, Lyse
    Cherruault, Marlene
    Jost, Paul-Henri
    Couffin, Severine
    Tomberli, Francoise
    Bardon, Jean
    Lahiani, Wissem
    Dhonneur, Gilles
    Cook, Fabrice
    Lebeaux, David
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2019, 74 (11) : 3328 - 3336
  • [39] Reduction in external ventricular drain infection rate. Impact of a minimal handling protocol and antibiotic-impregnated catheters
    Mónica Rivero-Garvía
    Javier Márquez-Rivas
    Manuel Enrique Jiménez-Mejías
    Olaf Neth
    Ana Belén Rueda-Torres
    Acta Neurochirurgica, 2011, 153 : 647 - 651
  • [40] Reduction in external ventricular drain infection rate. Impact of a minimal handling protocol and antibiotic-impregnated catheters
    Rivero-Garvia, Monica
    Marquez-Rivas, Javier
    Enrique Jimenez-Mejias, Manuel
    Neth, Olaf
    Belen Rueda-Torres, Ana
    ACTA NEUROCHIRURGICA, 2011, 153 (03) : 647 - 651